Restoration of the stilling basin of the Drtijs']jscica dam

被引:0
|
作者
Humar, N. [1 ]
Kryzanowski, A. [2 ]
机构
[1] Hidrotehnik Dd, Ljubljana, Slovenia
[2] Fac Civil Engn, Ljubljana, Slovenia
关键词
Bottom outlet; damage; earth fill dam; erosion; flood; scour protection; stilling basin;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Drtijscica dam and the reservoir represent the most important part of the flood protection system in the motorway section to the northeast of the city of Ljubljana. The reservoir is designed as a relief system for retention of peak discharges of flood waves, enabling higher flood safety for the entire area along the motorway. The dam is an earth dam with a central clay core, having a height of 18 m and a crest length of 256 m. The evacuation of water through the dam cross-section is through a shaft overspill and the bottom outlet into the channel of the Drtijscica stream. In September, 2010 a flood event occurred, when the high waters were in the range of the designed maximum flow. During the evacuation of flood water extensive erosion-induced damage to the stilling basin of the bottom outlet and the right part of the toe of the dam occurred. After the conditions steadied, the damaged structures were rehabilitated in the matter of priorities, together with the proposal of minor improvements of the original design, where this proved justified. After the event, an analysis of the conditions during the flood event was performed, where it was found that the damages were the result of several factors: firstly, there were exceptional operational conditions that exceeded the normal operational conditions, secondly, the end-part of the bottom outlet was inadequately designed, and, thirdly, the hydraulic conditions downstream of the dam were inadequate. For determination of the final solution a comprehensive redesign of the evacuation structures on the dam will be needed, taking into account the conclusions of the analysis of the 2010 event.
引用
收藏
页码:550 / 559
页数:10
相关论文
共 50 条
  • [31] Design of stilling basin for circular pipe outlets
    Goel, Arun
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2008, 35 (12) : 1365 - 1374
  • [32] RESEARCH TO THE STILLING BASIN TYPES OF THE SPILLWAY OUTLET
    Lv, Jiacai
    Liu, Mingming
    ADVANCES IN WATER RESOURCES AND HYDRAULIC ENGINEERING, VOLS 1-6, 2009, : 1536 - 1540
  • [33] Laboratory Investigation of Stilling Basin Slope Effect on Bed Scour at Downstream of Stepped Spillway: Physical Modeling of Javeh RCC Dam
    Elnaz Eghlidi
    Gholam-Abbas Barani
    Kourosh Qaderi
    Water Resources Management, 2020, 34 : 87 - 100
  • [34] CAVITATION INDUCED BY TURBULENCE IN STILLING BASIN - CLOSURE
    NARAYANAN, R
    JOURNAL OF THE HYDRAULICS DIVISION-ASCE, 1981, 107 (10): : 1271 - 1271
  • [35] Hydraulics of stilling basin with flaring gate piers
    Li, Zhong-shu
    Pan, Yan-hau
    Han, Lian-chao
    Chang, Zhi-tao
    Shuikexue Jinzhan/Advances in Water Science, 2000, 11 (01): : 82 - 87
  • [36] Performance of a stilling basin with partially short walls
    Zarrati, AR
    Alehossein, SA
    WATER RESOURCES ENGINEERING 98, VOLS 1 AND 2, 1998, : 1452 - 1457
  • [37] STILLING BASIN DESIGN FOR LOW FROUDE NUMBER
    BHOWMIK, NG
    JOURNAL OF THE HYDRAULICS DIVISION-ASCE, 1975, 101 (07): : 901 - 915
  • [38] CAVITATION INDUCED BY TURBULENCE IN STILLING BASIN - DISCUSSION
    BLAZEJEWSKI, R
    JOURNAL OF THE HYDRAULICS DIVISION-ASCE, 1981, 107 (02): : 244 - 245
  • [39] Laboratory Investigation of Stilling Basin Slope Effect on Bed Scour at Downstream of Stepped Spillway: Physical Modeling of Javeh RCC Dam
    Eghlidi, Elnaz
    Barani, Gholam-Abbas
    Qaderi, Kourosh
    WATER RESOURCES MANAGEMENT, 2020, 34 (01) : 87 - 100
  • [40] Discussion: Numerical analysis of flow profile in a stilling basin
    Bagatur, T
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MANAGEMENT, 2005, 158 (03) : 131 - 131