Comparison of three methods for measuring factor VIII levels in plasma

被引:45
|
作者
Chandler, WL [1 ]
Ferrell, C [1 ]
Lee, J [1 ]
Tun, T [1 ]
Kha, H [1 ]
机构
[1] Univ Washington, Dept Lab Med, Seattle, WA 98195 USA
关键词
factor VIII; activity assay; chromogenic assay; immunoassay;
D O I
10.1309/C8T8YNB4G3W45PRF
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
We compared 1-stage clot-based, chromogenic, and immunoassay methods for measuring factor VIII in plasma with a focus on the measurement of elevated levels of factor VIII. The chromogenic assay showed the best interassay imprecision for factor VIII levels near 150 IU/dL. The best correlation was between the 1-stage clot-based and chromogenic factor VIII assays (r(2) = 0.934), and the lowest correlation was between the I-stage clot-based and antigenic factor VIII assays (r(2) = 0.821). The presence of heparin, low-molecular-weight heparin, lepirudin, or lupus inhibitors in the sample resulted in major interference in the 1-stage clot-based assay but not the chromogenic or antigenic factor VIII assays. Overall, the chromogenic factor VIII activity assay was the optimal method, showing good precision, the best overall correlation with other assays, and no interference from heparin, low-molecular-weight heparin, lepirudin, or lupus inhibitors.
引用
收藏
页码:34 / 39
页数:6
相关论文
共 50 条
  • [41] ACCUMULATIVE EFFECT OF DDAVP AND HEPARIN IN INCREASING PLASMA FACTOR-VIII LEVELS
    ROCK, G
    PALMER, DS
    VOX SANGUINIS, 1981, 41 (01) : 56 - 60
  • [42] COMPARISON OF FACTOR-VIII CLOTTING ASSAY WITH A FACTOR-VIII CHROMOGENIC ASSAY IN PLASMA FROM NORMAL CONTROLS AND IN PLASMA OBTAINED DURING PREGNANCY
    VANDIEIJENVISSER, MP
    VANWERSCH, JWJ
    FRANSSEN, J
    HEMKER, HC
    VANDIEIJEN, G
    BLUT, 1984, 49 (02): : 140 - 141
  • [43] Variations of factor VIII:C plasma levels with respect to the blood group ABO
    Jeanne, M
    Piquet, Y
    Ivanovic, Z
    Vezon, G
    Salmi, LR
    TRANSFUSION MEDICINE, 2004, 14 (02) : 187 - 188
  • [44] High plasma levels of factor VIII and the risk of recurrent venous thromboembolism.
    Hari, P
    Chemiti, GKP
    Lankipalli, RS
    NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (26): : 1968 - 1968
  • [45] High plasma levels of factor VIII and the risk of recurrent venous thromboembolism.
    Kyrle, PA
    Minar, E
    Hirschl, M
    Bialonczyk, C
    Stain, M
    Schneider, B
    Weltermann, A
    Speiser, W
    Lechner, K
    Eichinger, S
    NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (07): : 457 - 462
  • [46] Relationships between factor VIII:Ag and factor VIII in recombinant and plasma-derived factor VIII concentrates
    Lin, Y
    Yang, X
    Chevrier, MC
    Craven, S
    Barrowcliffe, TW
    Lemieux, R
    Ofosu, FA
    HAEMOPHILIA, 2004, 10 (05) : 459 - 469
  • [47] Comparison of three methods for measuring PEG-hirudin in blood
    Hoffmann, JJML
    Janssen, WCM
    BLOOD COAGULATION & FIBRINOLYSIS, 2001, 12 (07) : 577 - 581
  • [48] THREE METHODS FOR MEASURING THE SHIELDING EFFECTIVENESS OF SHIELDING MATERIALS: A COMPARISON
    Pocai, Mario
    Dotto, Ivan
    Festa, Domenico
    2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2012, : 653 - 658
  • [49] Comparison of Three Methods for Measuring Workload in Surgical Pathology and Cytopathology
    Cloetingh, Daniel
    Schmidt, Rodney A.
    Kong, Christina S.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2017, 148 (01) : 16 - 22
  • [50] Measuring diet cost at the individual level: a comparison of three methods
    P Monsivais
    M M Perrigue
    S L Adams
    A Drewnowski
    European Journal of Clinical Nutrition, 2013, 67 : 1220 - 1225