Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia

被引:11
|
作者
Choi, Jong Bum [1 ]
Kwak, Hyun Jeong [2 ]
Lee, Kyung Cheon [2 ]
Lee, Se Ryeon [3 ]
Lee, Sook Young [3 ]
Kim, Jong Yeop [3 ]
机构
[1] Yonsei Univ, Coll Med, Anesthesia & Pain Res Inst, Dept Anesthesiol & Pain Med, Seoul, South Korea
[2] Gachon Univ, Gil Med Ctr, Dept Anesthesiol & Pain Med, Inchon, South Korea
[3] Ajou Univ, Sch Med, Dept Anesthesiol & Pain Med, San 5, Suwon 443721, South Korea
关键词
i-gel; Laryngeal mask airway; Remifentanil; TARGET-CONTROLLED INFUSION; SUPRAGLOTTIC AIRWAY; CONFIDENCE-INTERVALS; REQUIREMENTS; INDUCTION; DESIGN; TERMS; TUBE; CUFF;
D O I
10.1007/s00540-015-2133-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Each supraglottic airway requires different anesthetic depth because it has a specific structure and different compressive force in the oropharyngeal cavity. We designed the study to compare the effect-site concentration (Ce) of remifentanil in 50 % of patients (EC50) for successful insertion of the i-gel second-generation supraglottic airway device with that for laryngeal mask airway (LMA) insertion during target-controlled infusion (TCI) of propofol. Forty-one female patients were randomized to the i-gel group (n = 20) or the LMA group (n = 21). Anesthesia was induced with propofol Ce of 5 mu g/ml and the predetermined remifentanil Ce, and the i-gel or LMA was inserted 5 min later. The remifentanil Ce was estimated by modified Dixon's up-and-down method (initial concentration: 3.0 ng/ml, step size: 0.5 ng/ml). The patient's response to device insertion was classified as either "success (no movement)" or "failure (movement)". Using the Dixon's up-and-down method, EC50 of remifentanil Ce for the i-gel (1.58 +/- 0.41 ng/ml) was significantly lower than that for LMA (2.25 +/- 0.55 ng/ml) (p = 0.038). Using isotonic regression, EC50 (83 % CI) of remifentanil in the i-gel group [1.50 (1.37-1.80) ng/ml] was statistically lower than that in the LMA group [2.00 (1.82-2.34) ng/ml]. EC95 (95 % CI) of remifentanil in the i-gel group [2.38 (1.48-2.50) ng/ml] was statistically lower than that in the LMA group [3.35 (2.58-3.48) ng/ml]. We found that EC50 of remifentanil Ce for i-gel insertion (1.58 ng/ml) was significantly lower than that for LMA insertion (2.25 ng/ml) in female patients during propofol TCI without neuromuscular blockade.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [41] Combination of propofol and remifentanil target-controlled infusion for laryngeal mask airway insertion in children
    Kim, H. -S.
    Park, H. -J.
    Kim, C. S.
    Lee, J. -R.
    MINERVA ANESTESIOLOGICA, 2011, 77 (07) : 687 - 692
  • [42] Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
    Singh, Jeevan
    Yadav, Manohar Kumar
    Marahatta, Sujan Babu
    Shrestha, Bikash Lal
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 348 - 352
  • [43] EFFICIENCY OF PROPOFOL CO-ADMINISTERED WITH REMIFENTANIL AND FENTANYL OVER LARYNGEAL MASK AIRWAY INSERTION
    Urfali, Senem
    Aykut, Buket Cagla Ozbakis
    FARMACIA, 2017, 65 (03) : 472 - 478
  • [44] A Comparison of Propofol Plus Sevoflurane Versus Propofol alone for Laryngeal Mask Airway Insertion
    Draz, Omar
    Saeed, Yahya
    Alia, Iram
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2013, 7 (01): : 42 - 45
  • [45] Emergency airway management by paramedics: comparison between standard endotracheal intubation, laryngeal mask airway, and I-gel
    Leventis, Charalampos
    Chalkias, Athanasios
    Sampanis, Michail A.
    Foulidou, Xanthipi
    Xanthos, Theodoros
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2014, 21 (05) : 371 - 373
  • [46] Reply to Letter: Comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway
    Michalek, Pavel
    Donaldson, William
    RESUSCITATION, 2010, 81 (07) : 911 - 911
  • [47] A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study
    Michalek, P.
    Donaldson, W.
    Graham, C.
    Hinds, J. D.
    RESUSCITATION, 2010, 81 (01) : 74 - 77
  • [48] A comparison of supraglottic airway i-gel (TM) vs. classic laryngeal mask airway in small children
    Lee, Ju-Hyun
    Cho, Hyun-Seok
    Shin, Won-Jung
    Yang, Hong-Seuk
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 66 (02) : 127 - 130
  • [49] Einsatz der i-gel®-Larynxmaske bei schwierigem AtemwegUse of the i-gel® laryngeal mask for management of a difficult airway
    M. Emmerich
    R. Dummler
    Der Anaesthesist, 2008, 57 : 779 - 781
  • [50] Comparing i-gel and Ambu AuraOnce laryngeal mask airway in pediatric patients
    Yang, Gui-Zhen
    Xue, Fu-Shan
    Li, Hui-Xian
    Liu, Ya-Yang
    SAUDI MEDICAL JOURNAL, 2017, 38 (12) : 1262 - 1262