Strength capacity of unreinforced masonry cylindrical columns under seismic transverse forces

被引:8
|
作者
Gurel, M. Arif [1 ]
Pekgokgoz, R. Kadir [1 ]
Cili, Feridun [2 ]
机构
[1] Harran Univ, Dept Civil Engn, Sanliurfa, Turkey
[2] Istanbul Tech Univ, Fac Architecture, TR-80626 Istanbul, Turkey
关键词
Seismic resistance; Unreinforced masonry; Cylindrical columns; Cracking; BOUNDED COMPRESSIVE STRENGTH; STABILITY; WALLS; DEFORMABILITY; TESTS; PIERS; MODEL;
D O I
10.1007/s10518-011-9297-8
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this paper, the seismic resistance of unreinforced masonry (URM) cylindrical columns is investigated with an equivalent static analysis procedure. To this end, an existing numerical model developed for the stability analysis of masonry elements with rectangular cross-section is utilized and modified for the cylindrical columns. In the numerical model which takes into account the cracking of the sections and the second-order effects, the columns are divided ideally into sufficiently high number of elements, each having uniform curvature. The columns are modeled as prismatic cantilevers undergoing their own weights, eccentric vertical loads and distributed and concentrated static horizontal loads equivalent to the inertia actions. By considering two examples of columns, firstly a reference column and secondly a column from a real building, lateral seismic coefficient versus top drift level curves are obtained. On the basis of these curves, lateral load behavior of the columns is interpreted and maximum seismic load values which can be resisted by each column are determined. Implementing parametric analyses on the reference column, sensitivity of the seismic resistance to parameters such as column slenderness, magnitude and eccentricity of vertical top load, and the flexibility parameter is determined. The influence of some structural imperfections such as the deviation from vertical on the seismic resistance is also discussed in the paper.
引用
收藏
页码:587 / 613
页数:27
相关论文
共 50 条
  • [11] Seismic Capacity Assessment of Unreinforced Concrete Block Masonry Buildings in Pakistan Before and After Retrofitting
    Ahmad, Zeeshan
    Shahzada, Khan
    Gencturk, Bora
    Naeem Khan, Akhtar
    Rehan, Rashid
    Fahad, Muhammad
    Ashraf, Muhammad
    Ali, Zaigham
    JOURNAL OF EARTHQUAKE ENGINEERING, 2015, 19 (03) : 357 - 382
  • [12] Evaluating the seismic out-of-plane capacity of unreinforced masonry walls: effects of cantilevered masses
    Helm, Lukas
    Sadegh-Azar, Hamid
    KERNTECHNIK, 2025, 90 (01) : 2 - 10
  • [13] Seismic Vulnerability Assessment of Historical Unreinforced Masonry Buildings in Osijek using Capacity Spectrum Method
    Pavic, G.
    Hadzima-Nyarko, M.
    Plascak, I.
    Pavic, S.
    ACTA PHYSICA POLONICA A, 2019, 135 (05) : 1138 - 1142
  • [14] Assessment of Seismic Capacity for Reinforced Concrete Frames with Perforated Unreinforced Brick Masonry Infill Wall
    Umar, Muhammad
    Shah, Syed Azmat Ali
    Shahzada, Khan
    Naqash, Muhammad Tayyab
    Ali, Wajid
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2020, 6 (12): : 2397 - 2415
  • [15] FRACTURES DETECTION IN MASONRY CONSTRUCTIONS UNDER HORIZONTAL SEISMIC FORCES
    Iannuzzo, Antonino
    De Luca, Antonello
    Fortunato, Antonio
    Gesualdo, Antonio
    Angelillo, Maurizio
    INGEGNERIA SISMICA, 2018, 35 (03): : 87 - 103
  • [16] Behavior of precast composite columns under axial and transverse forces
    Ercan, Emre
    Hokelekli, Emin
    Arisoy, Bengi
    JOURNAL OF BUILDING ENGINEERING, 2022, 44
  • [17] Evaluation of the Performance of Unreinforced Stone Masonry Greek "Basilica" Churches When Subjected to Seismic Forces and Foundation Settlement
    Manos, George C.
    Kotoulas, Lambros
    Kozikopoulos, Evangelos
    BUILDINGS, 2019, 9 (05)
  • [18] In-plane strength under seismic forces of multi-storey masonry walls reinforced by steel ties
    Coccia, S.
    Como, M.
    Di Carlo, F.
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 145 - 153
  • [19] Distinct Element Modelling of Unreinforced Masonry Wall Under Seismic Loads with and without Cable Retrofitting
    ZHUGE Yan (School of Natural and Built Environments
    Transactions of Tianjin University, 2008, (S1) : 471 - 475
  • [20] Distinct element modelling of unreinforced masonry wall under seismic loads with and without cable retrofitting
    Zhuge Y.
    Trans. Tianjin Univ., 2008, SUPPL. (471-475): : 471 - 475