Analgesic Effect of Transcutaneous Electrical Nerve Stimulation After Laparoscopic Cholecystectomy

被引:38
|
作者
Silva, Maristella Borges [2 ]
de Melo, Patricia Roberta
Lopes de Oliveira, Nuno Miguel [1 ]
Crema, Eduardo [3 ]
Rodrigues Martinho Fernandes, Luciane Fernanda [1 ]
机构
[1] Univ Fed Triangulo Mineiro, Dept Appl Phys Therapy, Uberaba, MG, Brazil
[2] Univ Fed Uberlandia, Biomed Engn Lab, BR-38400 Uberlandia, MG, Brazil
[3] Univ Fed Triangulo Mineiro, Sch Med, Uberaba, MG, Brazil
关键词
Transcutaneous Electrical Nerve Stimulation; Pain; Analgesia; Cholecystectomy; POSTOPERATIVE PAIN; TENS; HYPOALGESIA; MANAGEMENT; FREQUENCY; RELIEF; SCALE;
D O I
10.1097/PHM.0b013e318246638f
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Silva MB, de Melo PR, de Oliveira NML, Crema E, Fernandes LFRM: Analgesic effect of transcutaneous electrical nerve stimulation after laparoscopic cholecystectomy. Am J Phys Med Rehabil 2012; 91: 652-657. Objective: This study aimed to assess the effect of Transcutaneous Electrical Nerve Stimulation (TENS) on pain, nausea, and emesis in patients submitted to surgery for laparoscopic cholecystectomy. Design: A clinical single-masked randomized study assessed patients submitted to laparoscopic cholecystectomy, who were divided into two groups: placebo TENS (G1) and active TENS (G2). The intensity of pain was determined using the visual analog scale and the 11-point Verbal Numerical Scale, applied to the participants before (M1) and 30 mins after (M2) TENS. A conventional biphasic square pulse TENS current was used, at a frequency of 150 Hz and a pulse width of 75 mu secs. The relative risks of the occurrence of nausea and emesis were calculated for groups G1 and G2. Determination of the effect of TENS on analgesia used the Mann-Whitney U test, at a significance level of 5%, to compare independent samples (Dif G1 and Dif G2). Results: The relative risk of nausea and/or emesis was 2.17 times greater for patients from the placebo group. Pain evaluation using the visual analog scale showed median differences between M1 and M2 of 0.4 and 2.4 for groups G1 and G2, respectively. The values obtained using Verbal Numerical Scale were 0.7 (G1) and 3.0 (G2). The active TENS significantly reduced postoperative pain compared with the placebo (P < 0.016). Conclusions: Active TENS promoted significant postoperative pain relief, and fewer complaints of nausea and emesis, in patients submitted to laparoscopic cholecystectomy surgery.
引用
收藏
页码:652 / 657
页数:6
相关论文
共 50 条
  • [31] Transcutaneous Electrical Nerve Stimulation for Spasticity
    Etoom, Mohammad
    Khraiwesh, Yazan
    Foti, Calogero
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2017, 96 (11) : E198 - E198
  • [32] Transcutaneous Electrical Nerve Stimulation: An Overview
    Waller-Wise, Renece
    JOURNAL OF PERINATAL EDUCATION, 2022, 31 (01): : 49 - 57
  • [33] TRANSCUTANEOUS ELECTRICAL NERVE-STIMULATION
    MCLACHLAN, JC
    LANCET, 1991, 337 (8743): : 742 - 742
  • [34] Transcutaneous electrical stimulation of the trigeminal nerve
    Leonhardt, G.
    Schulze-Bonhage, A.
    ZEITSCHRIFT FUR EPILEPTOLOGIE, 2014, 27 (01): : 31 - 35
  • [35] THE EFFECT OF TRANSCUTANEOUS ELECTRICAL NERVE-STIMULATION ON OCULAR PAIN
    WHITACRE, MM
    OPHTHALMIC SURGERY AND LASERS, 1991, 22 (08): : 462 - 466
  • [36] Effect of transcutaneous electrical nerve stimulation on the postpartum dyspareunia treatment
    Dionisi, Barbara
    Senatori, Roberto
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2011, 37 (07) : 750 - 753
  • [37] The effect of chest wall transcutaneous electrical nerve stimulation on dyspnoea
    Torry, M
    Wilcock, A
    Cooper, BG
    Tattersfield, AE
    RESPIRATION PHYSIOLOGY, 1996, 104 (01): : 23 - 28
  • [38] The effect of transcutaneous nerve stimulation (TENS) on gastric electrical activity
    Furgala, A
    Thor, PJ
    Kolasinska-Kloch, W
    Krygowska-Wajs, A
    Kopp, B
    Laskiewicz, J
    JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2001, 52 (04): : 603 - 610
  • [39] Effect of transcutaneous electrical nerve stimulation induced parotid stimulation on salivary flow
    Pattipati, Sreenivasulu
    Patil, Rajendra
    Kannan, N.
    Kumar, Praveen B.
    Shirisharani, G.
    Mohammed, Rezwana Begum
    CONTEMPORARY CLINICAL DENTISTRY, 2013, 4 (04) : 427 - 431
  • [40] FAILURE OF TRANSCUTANEOUS ELECTRICAL NERVE-STIMULATION AND INDOMETHACIN TO REDUCE OPIATE REQUIREMENT FOLLOWING CHOLECYSTECTOMY
    LAITINEN, J
    NUUTINEN, L