Electrochemical determination of L-dopa at cobalt hexacyanoferrate/large-mesopore carbon composite modified electrode

被引:40
|
作者
Yan, Xue [1 ]
Pan, Deng [1 ]
Wang, Huan [1 ]
Bo, Xiangjie [1 ]
Guo, Liping [1 ]
机构
[1] NE Normal Univ, Fac Chem, Changchun 130024, Peoples R China
基金
中国国家自然科学基金;
关键词
L-dopa; Cobalt hexacyanoferrate; Large-mesopore carbon; Electrochemical determination; MODIFIED GLASSY-CARBON; ASCORBIC-ACID; VOLTAMMETRIC DETERMINATION; ELECTROCATALYTIC OXIDATION; AMPEROMETRIC SENSOR; LEVODOPA; NOREPINEPHRINE; EPINEPHRINE; NANOTUBE; PHARMACEUTICALS;
D O I
10.1016/j.jelechem.2011.09.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a cobalt hexacyanoferrate/large-mesopore carbon modified glassy carbon electrode (CoHCF-LMC/GC) was simply fabricated by electrodepositing CoHCF film on LMC. The electrochemical behaviors of L-dopa at this modified electrode have been studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and amperometry. The results show that the CoHCF-LMC modified electrode exhibits efficiently electrochemical activity for L-dopa oxidation in 0.1 M PBS (pH = 7.4), and the quantitative determination of L-dopa is unperturbed by the ascorbic acid (AA). Amperometry results depict that the proposed sensor provides excellent performance towards the determination of L-dopa with a low detection limit of 1.7 x 10(-8) M in the wide concentration range from 1.0 x 10(-7) to 1.9 x 10(-3) M at +0.20 V versus Ag/AgCl. Moreover, the studied composite electrode exhibits a good reproducibility and long-term stability. Determination of L-dopa in commercial tablets and human blood serum with satisfying results was also investigated by the proposed composite electrode. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 50 条
  • [21] Highly sensitive simultaneous determination of L-dopa and paracetamol using a glassy carbon electrode modified with a composite of nickel hydroxide nanoparticles/multi-walled carbon nanotubes
    Babaei, Ali
    Sohrabi, Masoud
    Taheri, Ali Reza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 698 : 45 - 51
  • [22] Electrocatalytic determination of thiols using hybrid copper cobalt hexacyanoferrate modified glassy carbon electrode
    Sharma, Vivek Vishal
    Guadagnini, Lorella
    Giorgetti, Marco
    Tonelli, Domenica
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 16 - 24
  • [23] Review. Electrochemical sensors used in the determination of L-Dopa
    State, Ramona Georgescu
    van Staden, Jacobus Frederick
    ELECTROCHEMICAL SCIENCE ADVANCES, 2022, 2 (01):
  • [24] Electrochemical sensor for tryptophan determination based on copper-cobalt hexacyanoferrate film modified graphite electrode
    Liu, Yingju
    Xu, Li
    SENSORS, 2007, 7 (10) : 2446 - 2457
  • [25] Electrochemical determination of antioxidant activity of blood plasma using glassy carbon modified with cobalt hexacyanoferrate
    A. K. Evseev
    V. N. Andreev
    E. S. Kondratueva
    M. M. Goldin
    Protection of Metals and Physical Chemistry of Surfaces, 2015, 51 : 310 - 312
  • [26] Electrochemical determination of antioxidant activity of blood plasma using glassy carbon modified with cobalt hexacyanoferrate
    Evseev, A. K.
    Andreev, V. N.
    Kondratueva, E. S.
    Goldin, M. M.
    PROTECTION OF METALS AND PHYSICAL CHEMISTRY OF SURFACES, 2015, 51 (02) : 310 - 312
  • [27] Electrochemical Determination of L-Dopa in Mucuna pruriens Seeds, Leaves and Commercial Siddha Product Using Gold Modified Pencil Graphite Electrode
    Kalachar, H. C. B.
    Basavanna, S.
    Viswanatha, R.
    Naik, Y. Arthoba
    Raj, D. Ananda
    Sudhad, P. N.
    ELECTROANALYSIS, 2011, 23 (05) : 1107 - 1115
  • [28] Selective Electrochemical Determination of L-Cysteine by a Cobalt Carbon Nanotube (CNT)-Modified Glassy Carbon Electrode (GCE)
    Kivrak, Hilal
    Selcuk, Kadir
    Caglar, Aykut
    Aktas, Nahit
    ANALYTICAL LETTERS, 2024, 57 (17) : 2798 - 2812
  • [29] Electrochemical behavior of L-dopa at single-wall carbon nanotube-modified glassy carbon electrodes
    Yan, XX
    Pang, DW
    Lu, ZX
    Lü, HQ
    Tong, H
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 569 (01) : 47 - 52