Comparison of the Force Required for Dislodgement Between Secured and Unsecured Airways

被引:1
|
作者
Davenport, Curtis [1 ]
Martin-Gill, Christian [2 ]
Wang, Henry E. [3 ]
Mayrose, James [4 ]
Carlson, Jestin N. [2 ,5 ]
机构
[1] Allegheny Hlth Network, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Emergency Med, Pittsburgh, PA USA
[3] Univ Texas Hlth Sci Ctr Houston, Emergency Med, Houston, TX 77030 USA
[4] SUNY Buffalo State, Sch Profess, Buffalo, NY USA
[5] St Vincent Hlth Syst, Emergency Med, Erie, PA USA
关键词
intubation; supraglottic airway; cardiac arrest; CHEST COMPRESSIONS; ENDOTRACHEAL; PARAMEDICS;
D O I
10.1080/10903127.2018.1459979
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Airway device placement and maintenance are of utmost importance when managing critically ill patients. The best method to secure airway devices is currently unknown. Study Objective: We sought to determine the force required to dislodge 4 types of airways with and without airway securing devices. Methods: We performed a prospective study using 4 commonly used airway devices (endotracheal tube [ETT], laryngeal mask airway [LMA], King laryngeal tube [King], and iGel) performed on 5 different mannequin models. All devices were removed twice per mannequin in random order, once unsecured and once secured as per manufacturers' recommendations; Thomas Tube Holder (Laerdal, Stavanger, Norway) for ETT, LMA, and King; custom tube holder for iGel. A digital force measuring device was attached to the exposed end of the airway device and gradually pulled vertically and perpendicular to the mannequin until the tube had been dislodged, defined as at least 4 cm of movement. Dislodgement force was reported as the maximum force recorded during dislodgement. We compared the relative difference in the secured and unsecured force for each device and between devices using a random-effects regression model accounting for variability in the manikins. Results: The median dislodgment forces (interquartile range [IQR]) in pounds for each secured device were: ETT 13.3 (11.6, 14.1), LMA 16.6 (13.9, 18.3), King 21.7 (16.9, 25.1), and iGel 8 (6.8, 8.3). The median dislodgement forces for each unsecured device were: ETT 4.5 (4.3, 5), LMA 8.4 (6.8, 10.7), King 10.6 (8.2, 11.5), and iGel 3.9 (3.2, 4.2). The relative difference in dislodgement forces (95% confidence intervals) were higher for each device when secured: ETT 8.6 (6.2 to 11), LMA 8.8 (4.6 to 13), King 12.1 (7.2 to 16.6), iGel 4 (1.1 to 6.9). When compared to secured ETT, the King required greater dislodgement force (relative difference 8.6 [4.5-12.7]). The secured iGel required less force than the secured ETT (relative difference -4.8 [-8.9 to -0.8]). Conclusion: Compared with a secured device, an unsecured airway device requires only half the force to cause airway dislodgement. The secured King had the highest dislodgement force relative to the other studied devices.
引用
收藏
页码:778 / 781
页数:4
相关论文
共 50 条
  • [41] Comparison between model-based and measured force polytopes: towards isometric force capacity evaluation
    Rezzoug, N.
    Hernandez, V.
    Jacquier-Bret, J.
    Gorce, P.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 172 - 174
  • [42] COMPARISON BETWEEN PATIENTS WITH AND WITHOUT AIRWAYS OBSTRUCTION FROM THE SHEFFIELD COPD STUDY: IMPLICATIONS FOR POPULATION SCREENING
    Darby, A. C.
    Waterhouse, J. C.
    Young, C.
    Aziz, M.
    Wight, J.
    Billings, C. G.
    Billings, C.
    Stevens, V.
    Burton, C. M.
    Barber, C. M.
    Morgan, D.
    Blanc, P. D.
    Fishwick, D.
    THORAX, 2009, 64 : A157 - A157
  • [43] Effects of topical glucocorticoids on in vitro lactoferrin glandular secretion:: Comparison between human upper and lower airways
    Roca-Ferrer, J
    Mullol, J
    Pérez, M
    Xaubet, A
    Molins, L
    de Haro, J
    Shelhamer, J
    Picado, C
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2000, 106 (06) : 1053 - 1062
  • [44] Comparison of the intubation success rate between the intubating catheter and videolaryngoscope in difficult airways: a prospective randomized trial
    Ozdemirkan, Aysun
    Onal, Ozkan
    Ozcan, Irem Gumus
    Aslanlar, Emine
    Saltali, Ali
    Sari, Mehmet
    Ciftci, Cansu
    Bayram, Hasan Huseyin
    BRAZILIAN JOURNAL OF ANESTHESIOLOGY, 2022, 72 (01): : 55 - 62
  • [45] Comparison between spring balancer and gravity balancer in inertia force and performance
    Kobayashi, K
    JOURNAL OF MECHANICAL DESIGN, 2001, 123 (04) : 549 - 555
  • [46] The driving force in trocar insertion - A comparison between disposable and reusable trocars
    Kelty, CJ
    Super, PA
    Stoddard, CJ
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2000, 14 (11): : 1045 - 1046
  • [47] A comparison between the GlideScope® Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways - a pilot study
    Karsli, C.
    Armstrong, J.
    John, J.
    ANAESTHESIA, 2010, 65 (04) : 353 - 357
  • [48] Female labor force participation: A comparison between urban and rural families
    Caiumi, A
    Perali, F
    AMERICAN JOURNAL OF AGRICULTURAL ECONOMICS, 1997, 79 (02) : 595 - 601
  • [49] Comparison of Syringe Compression Force Between ENFit and Legacy Feeding Tubes
    Mundi, Manpreet S.
    Duellman, Wanda
    Epp, Lisa
    Davidson, Jacob
    Hurt, Ryan T.
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2019, 43 (01) : 107 - 117
  • [50] COMPARISON OF THE RELATION BETWEEN INTEGRATED EMG AND FORCE IN SOME LIMB MUSCLES
    HARA, T
    JOURNAL OF THE ANTHROPOLOGICAL SOCIETY OF NIPPON, 1979, 87 (03): : 339 - 345