A description of the portable CO, Non-dispersive infrared detector (NDIR) is presented. The apparatus system principle and structure, experimental test technique including the circuit design and a method for calculating the sensor output data are discussed. The total uncertainty (99% confidence limits) obtained is +/-10 ppm at concentration range from 10 to 2000ppm of CO2.
引用
收藏
页码:675 / 685
页数:11
相关论文
共 50 条
  • [21] Self Powered Non-Dispersive Infra-Red CO2 Gas Sensor
    Gibson, D. R.
    MacGregor, C.
    SENSORS & THEIR APPLICATIONS XVI, 2011, 307
  • [22] Temperature compensation model for non-dispersive infrared CO2 gas sensor based on WOA-BP algorithm
    Su, Maoyuan
    Chen, Yumin
    Li, Qian
    Wei, Yang
    Liu, Jiansheng
    Chang, Zhengwei
    Liu, Xueyuan
    Zhang, Anan
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [23] Limitations of gas filter correlation: A case study on carbon monoxide non-dispersive infrared analyzer
    Dinh, Trieu-Vuong
    Ahn, Ji-Won
    Choi, In-Young
    Song, Kyu-Yong
    Chung, Chang-Ho
    Kim, Jo-Chun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 684 - 689
  • [24] Non-Dispersive Infrared Gas Sensing Technology: A Review
    Jha, Ravindra Kumar
    IEEE SENSORS JOURNAL, 2022, 22 (01) : 6 - 15
  • [25] PROCESS GAS ANALYZERS USING NON-DISPERSIVE INFRARED
    DURHAM, RM
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 411 : 72 - 79
  • [26] Concentration calculation model for calibration of non-dispersive infrared gas detection system
    Kim, Kum-Dong
    Song, Kil-Song
    Hwang, Hyon-Ung
    Choe, Chol-Min
    Im, Song-Jin
    Pae, Ji-Song
    Ri, Chol-Song
    Ho, Kum-Song
    AIP ADVANCES, 2024, 14 (10)
  • [27] Measuring Regional Atmospheric CO2 Concentrations in the Lower Troposphere with a Non-Dispersive Infrared Analyzer Mounted on a UAV, Ogata Village, Akita, Japan
    Chiba, Takashi
    Haga, Yumi
    Inoue, Makoto
    Kiguchi, Osamu
    Nagayoshi, Takeshi
    Madokoro, Hirokazu
    Morino, Isamu
    ATMOSPHERE, 2019, 10 (09)
  • [28] PORTABLE CO2 ANALYZER
    不详
    MER-MARINE ENGINEERS REVIEW, 1995, : 52 - 52
  • [29] Development of High-Precision NO2 Gas Sensor Based on Non-Dispersive Infrared Technology
    Zhao, Yongmin
    Zhang, Congchun
    Ci, Guangteng
    Zhao, Xiaoguang
    Lv, Jinguang
    Liang, Jingqiu
    Ming, Anjie
    Wei, Feng
    Mao, Changhui
    SENSORS, 2024, 24 (13)
  • [30] Development of a bioreactor with an integrated non-dispersive infrared CO2 sensor for rapid and sensitive detection of Cr(VI) toxicity in water
    Phan, Thanh-Truc H.
    Nguyen, Hoang-Duy P.
    Nguyen, Nguyen-Phuong
    Nguyen, Hong-Nhung
    Duong, Thanh-Linh H.
    Tran, Boi-An
    Quang, Tang Ba
    Duy, Nguyen Phuc Thanh
    Khoa, Ta Dang
    Pham, Thuy-Phuong T.
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 486