Triple Leads Programmed to Perform as Longitudinal Guarded Cathodes in Spinal Cord Stimulation: A Modeling Study

被引:17
|
作者
Sankarasubramanian, Vishwanath [1 ]
Buitenweg, Jan R. [1 ]
Holsheimer, Jan [1 ]
Veltink, Peter [1 ]
机构
[1] Univ Twente, Inst Biomed Technol & Tech Med, MIRA, NL-7500 AE Enschede, Netherlands
来源
NEUROMODULATION | 2011年 / 14卷 / 05期
关键词
Constant anodal current ratio; guarded cathodes; low-thoracic; paresthesia; spinal cord stimulation; variable anodal current ratio; LOW-BACK-PAIN; PERCUTANEOUS ELECTRODES; MYELINATED NERVE; COLUMN FIBERS; DORSAL; SYSTEM; SUPERIORITY; EXCITATION; MANAGEMENT; GEOMETRY;
D O I
10.1111/j.1525-1403.2011.00383.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: In spinal cord stimulation, neurosurgeons increasingly tend to implant dual leads. Dual leads (longitudinal bipole/tripole) provide medio-lateral control over the recruited dorsal column (DC) area by steering the injected cathodal currents. However, the DC recruited area is suboptimal when dual aligned leads straddling the midline programmed as longitudinal guarded cathodes (+-+) are used instead of a single lead placed over the spinal cord midline with the same configuration. As a potential improvement, an additional third lead between the two aligned leads is modeled to maximize the medio-lateral extent of the DCs at the low-thoracic vertebral region (T10-T12). Methods and Materials: The University of Twente Spinal Cord Stimulation software (UT-SCS) is used in this modeling study. Longitudinal guarded cathodes were modeled on the low-thoracic vertebral region (T10-T12) using percutaneous triple lead configurations. The central lead was modeled over the spinal cord midline and the two lateral leads were modeled at several transverse distances to the midline lead. Medio-lateral field steering was performed with the midline lead and the second lead on each side to achieve constant anodal current ratios and variable anodal current ratios. Results: Reducing the transverse lead separation resulted in increasing the depths and widths of the recruited DC area. The triple lead configuration with the least transverse separation had the largest DC recruited area and usage range. The maximum DC recruited area (in terms of both depth and width) was always found to be larger under variable anodal current ratio than constant anodal current ratio conditions. Conclusions: Triple leads programmed to perform as longitudinal guarded cathodes provide more postoperative flexibility than single and dual leads in covering a larger width of the low-thoracic DCs. The transverse separation between the leads is a major determinant of the area and distribution of paresthesia.
引用
收藏
页码:401 / 410
页数:10
相关论文
共 50 条
  • [1] Triple Leads Programmed to Perform as Longitudinal Guarded Cathodes in Spinal Cord Stimulation: A Modeling Study COMMENTS
    Slavin, Konstantin V.
    Richter, Erich O.
    Alo, Kenneth M.
    NEUROMODULATION, 2011, 14 (05): : 411 - 411
  • [2] Numerical Analysis of Spinal Cord Stimulation with Triple Leads with Guarded Cathode
    Durlu, Caglayan
    Zengin, Reyhan
    Gencer, Nevzat Guneri
    Kucukdeveci, Fikret
    2015 19TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2015,
  • [3] Technical performance of percutaneous leads for spinal cord stimulation: A modeling study
    Manola, L
    Holsheimer, J
    Veltink, P
    NEUROMODULATION, 2005, 8 (02): : 88 - 99
  • [4] Spinal Cord Stimulation: A Triple Threat Therapy?
    Cao, Michael
    Saxon, Leslie A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (05) : 541 - 542
  • [5] Cervical Spinal Cord Stimulation: Percutaneous and Paddle Leads
    Owusu-Sarpong, Stephane
    Haider, Sameah
    Peris-Celda, Maria
    Wilock, Meghan
    Prusik, Julia
    Pilitsis, Julie
    JOURNAL OF NEUROSURGERY, 2016, 124 (04) : A1198 - A1198
  • [6] Technological Innovation in Spinal Cord Stimulation: Use of a Newly Developed Delivery Device for Introduction of Spinal Cord Stimulation Leads
    Loge, David
    De Coster, Olivier
    Washburn, Stephanie
    NEUROMODULATION, 2012, 15 (04): : 392 - 401
  • [7] Techniques for Safe Removal of Spinal Cord Stimulation Paddle Leads
    Topp, Gregory
    Harland, Tessa
    Spurgas, Morgan
    Rock, Andrew
    Pilitsis, Julie G.
    OPERATIVE NEUROSURGERY, 2022, 23 (06) : E348 - E352
  • [8] Factors affecting impedance of percutaneous leads in spinal cord stimulation
    Alò, K
    Varga, C
    Krames, E
    Prager, J
    Holsheimer, J
    Manola, L
    Bradley, K
    NEUROMODULATION, 2006, 9 (02): : 128 - 135
  • [9] Importance of Axial Migration of Spinal Cord Stimulation Trial Leads with Position
    Kim, Chong H.
    Green, Adam W.
    Rodgers, Drew E.
    Issa, Mohammed A.
    Ata, Monica A.
    PAIN PHYSICIAN, 2013, 16 (06) : E763 - E768
  • [10] Predictors of Skip Laminotomy for Placement of Paddle Leads for Spinal Cord Stimulation
    Harland, Tessa A.
    Staudt, Michael D.
    Bandlamuri, Sruti
    Juneja, Ankit
    Pilitsis, Julie G.
    Sukul, Vishad V.
    NEUROMODULATION, 2024, 27 (01): : 183 - 187