A New Adaptive Virtual Impedance based Fault Current Limiter for Converters

被引:0
|
作者
Beheshtaein, Siavash [1 ]
Golestan, Saeed [2 ]
Cuzner, Robert [1 ]
Guerrero, Josep M. [2 ]
机构
[1] Univ Wisconsin, Milwaukee, WI 53201 USA
[2] Aalborg Univ, Aalborg, Denmark
关键词
Converter; fault current limiter; moving average filter (MAF); protection; virtual impedance;
D O I
10.1109/ecce.2019.8912505
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Fault current limiter (FCL) can be used to prevent converters from being damaged and miscoordination of the protective relays. FCL must be designed to have high efficiency, fast response, and low implementation cost. Accordingly, this paper proposes an adaptive virtual impedance (VI) based FCL for a four-wire system. In normal condition the exerted additional VI is zero; however, once the fault occurs the VI of the faulty phase will be increased until it limits the output current of the converter to a specific value. In order to have a fast-acting FCL, an adaptive moving average filter phase locked loop has been proposed to measure the output current with the lowest possible time delay. Since the proposed FCL does not use any external device, the implementing cost is almost zero. In addition, it has a very high time response and only limits the current of the distribution generator (DG) faulted phase. This paper also provides real-time simulation results by simulation and experimental results to compare the proposed method with the non-adaptive virtual-impedance-based FCL to validate its effectiveness.
引用
收藏
页码:2439 / 2444
页数:6
相关论文
共 50 条
  • [41] Application of Superconducting Fault Current Limiter as a Virtual Inertia for DC Distribution Systems
    Yehia, Doaa M.
    Taha, Ibrahim B. M.
    IEEE ACCESS, 2021, 9 : 135384 - 135391
  • [42] A circulating current suppression strategy of VSG based on adaptive virtual complex impedance
    Zhang, Mi
    Mu, Longhua
    Chen, Guozhen
    Fang, ChongKai
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
  • [43] Adaptive virtual impedance droop control based on consensus control of reactive current
    Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning
    530004, China
    不详
    CT
    06516, United States
    Energies, 7
  • [44] A new current protection scheme based on a superconducting fault current limiter for a multi-stage feeder
    Chen Y.
    Lü L.
    Li Z.
    Ji H.
    Wan Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (24): : 86 - 94
  • [45] Research on a New Type of Fault Current Limiter Based on High Coupled Split Reactor
    Mo, Wenxiong
    Liu, Junxiang
    Wang, Yong
    Gan, Lin
    Su, Haibo
    Zhu, Lu
    Qiao, Shengya
    Wu, Kaijian
    Yuan, Zhao
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 1513 - 1522
  • [46] Adaptive Virtual Impedance for Reactive Current Control during Fault Conditions in Grid-Forming Inverters
    Shamseh, Mohammad Bani
    Li Haiqing
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 2251 - 2257
  • [47] New Topology of Superconducting Fault Current Limiter with Bypass Resistor
    Baimell, D.
    Barbi, Eli
    Bronstein, S.
    Baimel, N.
    Kuperman, A.
    2022 24TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'22 ECCE EUROPE), 2022,
  • [48] FUNDAMENTAL TEST OF NEW DC SUPERCONDUCTING FAULT CURRENT LIMITER
    ISHIGOHKA, T
    SASAKI, N
    IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) : 2341 - 2344
  • [49] Study of a new fault current limiter (FCL) with series compensation
    Chen, J.X.
    Dong, E.Y.
    Zou, J.Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2001, 16 (01):
  • [50] New Concept for Fault Current Limiter With Voltage Restoration Capability
    Nourmohamadi, Hesam
    Sabahi, Mehran
    Balsara, Poras T.
    Babaei, Ebrahim
    Hosseini, Seyed Hossein
    Fakhim-Babaei, Amir
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (12) : 10001 - 10010