Chromoionophoric ligand impregnated mesoporous polymeric optical sensors for the colorimetric quantification of Cu2+in water samples

被引:8
|
作者
Sivaraman, Sushmitha Pedugu [1 ]
Mohan, Akhila Maheswari [1 ]
机构
[1] Vellore Inst Technol VIT, Sch Adv Sci, Dept Chem, Vellore 632014, Tamil Nadu, India
关键词
Porous polymer; Monoliths; Optical sensors; Colorimetry; Copper; COPPER IONS; WASTE-WATER; SENSITIVE DETECTION; CU2+ IONS; REMOVAL; CHEMOSENSOR; CU(II); NANOPARTICLES; FLUORESCENT; FUNCTIONALIZATION;
D O I
10.1016/j.micromeso.2021.111390
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In this work, we demonstrate the use of simple, low-cost, benign, and portable solid-state optical sensor material constructed through direct immobilization of chromoionophoric probe onto a porous polymer monolithic template. The fabricated polymer template depicts superior sensing properties such as a high surface area with uniform porous networks, which is suitable for the homogenous dispersion of chromoionophoric probe onto the voluminous cavity of the polymer template. The surface morphological features and the structural analysis of the polymer template are characterized using p-XRD, TEM, SEM, SAED, EDAX, XPS, and N2 isotherm analysis. The impregnation of the probe, 2-(4-(dimethylamino)benzylidene)-N-phenylhydrazine-1-carbothioamide (DABNC) onto the pore surface of the polymer monolith renders superior sensing performance in capturing ultra-trace concentration of Cu(2+ )ions, which is inferred from a series of visual color transitions (dull white to sap green). The selective naked-eye color recognition is associated with the formation of stable charge-transfer complexes with the chelating sites of the probe molecules with Cu2+ ions. To ensure the effectiveness of ionsensing, analytical parameters such as solution pH, probe concentration, sensor dosage, temperature, response kinetics, and ion-selectivity amidst matrix ions are systematically optimized. The range of linear response signal is found to be 0-100 mu g/L, with a limit of detection and quantification values of 0.15 and 0.56 mu g/L, respectively. The used sensor material can be regenerated to its original state, without any loss of its sensing efficacy, up to six regenerative cycles. The practical applicability of the developed sensor is tested using various real water samples, and the analytical data obtained are reliable and reproducible (RSD <= 1.12%, n = 3).
引用
收藏
页数:11
相关论文
共 36 条
  • [31] Azocalix[4]pyrrole Amberlite XAD-2: New polymeric chelating resins for the extraction, preconcentration and sequential separation of Cu(II), Zn(II) and Cd(II) in natural water samples
    Jain, Vinod K.
    Mandalia, Hiren C.
    Gupte, Hrishikesh S.
    Vyas, Disha J.
    TALANTA, 2009, 79 (05) : 1331 - 1340
  • [32] Solid-phase extraction based on mesoporous Fe3O4@mSiO(2)@Cu2+ magnetic nanoparticles coupled with high performance liquid chromatography for the determination of microcystins in water samples
    Sun Hong
    Lou Dawei
    Lian Lili
    Han Xue
    Guo Tingxiu
    Chen Huijun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (05) : 449 - 454
  • [33] Monodisperse magnetic ion imprinted polymeric microparticles prepared by RAFT polymerization based on γ-Fe2O3@meso-SiO2 nanospheres for selective solid-phase extraction of Cu(II) in water samples
    Liu, Zhanchao
    Hu, Zhaoyong
    Liu, Yan
    Meng, Minjia
    Ni, Liang
    Meng, Xiangguo
    Zhong, Guoxing
    Liu, Fangfang
    Gao, Yanmin
    RSC ADVANCES, 2015, 5 (65) : 52369 - 52381
  • [34] A "Turn-Off" Pyrene-Based Ligand as a Fluorescent Sensor for the Detection of Cu2+ and Fe2+ Ions: Synthesis and Application in Real Water Samples, Logic Gate Construction, and Bio-Imaging
    Gowda, Bhavana G.
    Iqbal, Muzaffar
    Kollur, Shiva Prasad
    CHEMOSENSORS, 2024, 12 (06)
  • [35] Separation and preconcentration of inorganic arsenic species in natural water samples with 3-(2-aminoethylamino) propyltrimethoxysilane modified ordered mesoporous silica micro-column and their determination by inductively coupled plasma optical emission spectrometry
    Chen, Dahui
    Huang, Chaozhang
    He, Man
    Hu, Bin
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 164 (2-3) : 1146 - 1151
  • [36] Micro-column preconcentration/separation using thiacalix[4]arene tetracarboxylate derivative modified mesoporous TiO2 as packing materials on-line coupled to inductively coupled plasma optical emission spectrometry for the determination of trace heavy metals in environmental water samples
    Chen, Dahui
    Hu, Bin
    He, Man
    Huang, Chaozhang
    MICROCHEMICAL JOURNAL, 2010, 95 (01) : 90 - 95