Visualization of Middle Ear Ossicles in Elder Subjects with Ultra-short Echo Time MR Imaging

被引:3
|
作者
Naganawa, Shinji [1 ]
Nakane, Toshiki [1 ]
Kawai, Hisashi [1 ]
Taoka, Toshiaki [1 ]
Suzuki, Kojiro [1 ]
Iwano, Shingo [1 ]
Satake, Hiroko [1 ]
Grodzki, David [2 ]
机构
[1] Nagoya Univ, Dept Radiol, Grad Sch Med, Shouwa Ku, 65 Tsurumai Cho, Nagoya, Aichi 4668550, Japan
[2] Siemens Healthcare GmbH, Magnet Resonance Imaging, Erlangen, Germany
关键词
magnetic resonance imaging; ossicles; temporal bone disease; RADIAL ACQUISITION PETRA; CORTICAL BONE; FEASIBILITY; REDUCTION; SEQUENCE; POROSITY; WATER;
D O I
10.2463/mrms.mp.2015-0171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the visualization of middle ear ossicles by ultra-short echo time magnetic resonance (MR) imaging at 3T in subjects over 50 years old. Materials and Methods: Sixty ears from 30 elder patients that underwent surgical or interventional treatment for neurovascular diseases were included (ages: 50-82, median age: 65; 10 men, 20 women). Patients received follow-up MR imaging including routine T1-and T2-weighted images, time-of-flight MR angiography, and ultra-short echo time imaging (PETRA, pointwise encoding time reduction with radial acquisition). All patients underwent computed tomography (CT) angiography before treatment. Thin-section source CT images were correlated with PETRA images. Scan parameters for PETRA were: TR 3.13, TE 0.07, flip angle 6 degrees, 0.83 x 0.83 x 0.83 mm resolution, 3 min 43 s scan time. Two radiologists retrospectively evaluated the visibility of each ossicular structure as positive or negative using PETRA images. The structures evaluated included the head of the malleus, manubrium of the malleus, body of the incus, long process of the incus, and the stapes. Signal intensity of the ossicles was classified as: between labyrinthine fluid and air, similar to labyrinthine fluid, between labyrinthine fluid and cerebellar parenchyma, or higher than cerebellar parenchyma. Results: In all ears, the body of the incus was visible. The head of the malleus was visualized in 36/60 ears. The manubrium of the malleus and long process of the incus was visualized in 1/60 and 4/60 ears, respectively. The stapes were not visualized in any ear. Signal intensity of the visible structures was between labyrinthine fluid and air in all ears. Conclusion: The body of the incus was consistently visualized with intensity between air and labyrinthine fluid on PETRA images in aged subjects. Poor visualization of the manubrium of the malleus, long process of the incus, and the stapes limits clinical significance of middle ear imaging with current PETRA methods.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 50 条
  • [21] MRI of the brain with ultra-short echo-time pulse sequences
    Waldman, A
    Rees, JH
    Brock, CS
    Robson, MD
    Gatehouse, PD
    Bydder, GM
    NEURORADIOLOGY, 2003, 45 (12) : 887 - 892
  • [22] Characterization of the ultra-short echo time magnetic resonance (UTE MR) collagen signal associated with myocardial fibrosis
    Adrienne G Siu
    Andrew Ramadeen
    Xudong Hu
    Lily Morikawa
    Li Zhang
    Justin Lau
    Garry Liu
    Mihaela Pop
    Kim A Connelly
    Paul Dorian
    Graham A Wright
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [23] Ultra-short echo time images quantify high liver iron
    Doyle, Eamon K.
    Toy, Kristin
    Valdez, Bertin
    Chia, Jonathan M.
    Coates, Thomas
    Wood, John C.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1579 - 1585
  • [24] Ultra-short echo time spectroscopic imaging in rats:: implications for monitoring lipids in glioma gene therapy
    Liimatainen, Timo
    Hakumaeki, Juhana
    Tkac, Ivan
    Groehn, Olli
    NMR IN BIOMEDICINE, 2006, 19 (05) : 554 - 559
  • [25] MRI of the brain with ultra-short echo-time pulse sequences
    A. Waldman
    J. H. Rees
    C. S. Brock
    M. D. Robson
    P. D. Gatehouse
    G. M. Bydder
    Neuroradiology, 2003, 45 : 887 - 892
  • [26] Quantitative Assessment of Tracheomalacia Using Ultra-Short Echo Time MRI
    Hysinger, E.
    Bates, A.
    Higano, N. S.
    Hart, C. K.
    Benscoter, D.
    de Alacron, A.
    Fain, S. B.
    Kingma, P. S.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [27] Acquisition-weighted stack of spirals for fast high-resolution three-dimensional ultra-short echo time MR imaging
    Qian, Yongxian
    Boada, Fernando E.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 135 - 145
  • [28] Quantification of Calcifications in Endarterectomy Samples by Means of High-Resolution Ultra-Short Echo Time Imaging
    Sharma, Sonu
    Boujraf, Said
    Bornstedt, Axel
    Hombach, Vinzenz
    Ignatius, Anita
    Oberhuber, Alexander
    Rasche, Volker
    INVESTIGATIVE RADIOLOGY, 2010, 45 (03) : 109 - 113
  • [29] Viability of Oxygen-enhanced Ventilation Imaging of the Lungs Using Ultra-short Echo Time MRI
    Sasaki, Tomoaki
    Takahashi, Koji
    Obara, Makoto
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 259 - 261
  • [30] MR imaging of ultra-short T2 species in the brain
    Gold, GE
    Nayak, K
    Pauly, JM
    Nishimura, DG
    RADIOLOGY, 2000, 217 : 250 - 250