SuperSonic shear imaging for the differentiation between benign and malignant thyroid nodules: a meta-analysis

被引:6
|
作者
Chen, Y. [1 ]
Dong, B. [2 ]
Jiang, Z. [1 ]
Cai, Q. [1 ]
Huang, L. [1 ]
Huang, H. [1 ]
机构
[1] Fujian Med Univ, Dept Endocrinol, Affiliated Hosp 2, 34 North Zhongshan Rd, Quanzhou 362000, Fujian, Peoples R China
[2] Fujian Med Univ, Dept Ultrasound, Affiliated Hosp 2, Quanzhou, Fujian, Peoples R China
关键词
Thyroid; Diagnostic accuracy; Thyroid nodules; Ultrasound; Elastography; FINE-NEEDLE-ASPIRATION; WAVE ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; DIAGNOSTIC PERFORMANCE; RISK STRATIFICATION; WFUMB GUIDELINES; CLINICAL-USE; RECOMMENDATIONS; PARAMETERS; ACCURACY;
D O I
10.1007/s40618-022-01765-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To assess the diagnostic value of SuperSonic shear imaging (SSI) for the differentiation between benign and malignant thyroid nodules through meta-analysis. Methods Online database searches were performed on PubMed, EMBASE, the Cochrane Library, and the Web of Science until 31 July 2021. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the quality of the included studies. Three measures of diagnostic test performance were used to examine the value of SSI, including the summary area under the receiver operating characteristic curve (AUROC), the summary diagnostic odds ratio (DOR), and the summary sensitivity and specificity. Heterogeneity was explored using meta-regression and subgroup analyses. Results Finally, 21 studies with 3376 patients were included in this study. There were a total of 4296 thyroid nodules, in which 1806 malignant nodules and 2490 benign ones were involved. Thyroid nodules exhibited a malignancy rate of 42.0% (range 5.6-79.8%), 95.1% of which were of papillary variant. SSI showed a summary sensitivity of 74% [95% confidence interval (CI) 67-79%], specificity of 82% (95% CI 77-87%) and AUROC of 0.85 (95% CI 0.82-0.88) for the differentiation between benign and malignant thyroid nodules. The summary positive likelihood ratio (LR), negative LR, and DOR were 4.2 (95% CI 3.3-5.3), 0.32 (95% CI 0.26-0.40), and 13 (95% CI 9-18), respectively. Conclusions SSI showed high accuracy in the diagnostic differentiation between benign and malignant thyroid nodules and can be served as a noninvasive and important adjunct for thyroid nodule evaluation.
引用
收藏
页码:1327 / 1339
页数:13
相关论文
共 50 条
  • [21] Diffusion-weighted MRI in differentiating malignant from benign thyroid nodules: a meta-analysis
    Chen, Lihua
    Xu, Jian
    Bao, Jing
    Huang, Xuequan
    Hu, Xiaofei
    Xia, Yunbao
    Wang, Jian
    BMJ OPEN, 2016, 6 (01):
  • [22] Diagnostic accuracy of S-Detect in distinguishing benign and malignant thyroid nodules: A meta-analysis
    Zhong, Lin
    Wang, Cong
    PLOS ONE, 2022, 17 (08):
  • [23] Systematic review and meta-analysis: diagnostic value of different ultrasound for benign and malignant thyroid nodules
    Wu, Yin
    Zhou, Chunmei
    Shi, Bo
    Zeng, Zhuohua
    Wu, Xinyu
    Liu, Jiakai
    GLAND SURGERY, 2022, 11 (06) : 1067 - 1077
  • [24] Fractal Dimension Differentiation between Benign and Malignant Thyroid Nodules from Ultrasonography
    Yan, Yu
    Zhu, Wei
    Wu, Yi-yun
    Zhang, Dong
    APPLIED SCIENCES-BASEL, 2019, 9 (07):
  • [25] Contrast-Enhanced Ultrasound for Differentiation of Benign and Malignant Thyroid Lesions: Meta-analysis
    Yu, Dongmei
    Han, Yuna
    Chen, Taotao
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2014, 151 (06) : 909 - 915
  • [26] MicroRNAs as novel biomarkers for the differentiation of malignant versus benign thyroid lesions: a meta-analysis
    Zhou, G. J.
    Xiao, M.
    Zhao, L. N.
    Tang, J. G.
    Zhang, L.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (03): : 7279 - 7289
  • [27] Percutaneous laser ablation for benign thyroid nodules: a meta-analysis
    Sui, Wei Fan
    Li, Jian Yun
    Fu, Jian Hua
    ONCOTARGET, 2017, 8 (47) : 83225 - 83236
  • [28] Role of diffusion weighted magnetic resonance imaging in differentiation of benign and malignant thyroid nodules
    Shokry, Ahmed Mohamed
    Hassan, Talaat A.
    Baz, Ahmed A.
    Ahmed, Ahmed Shaaban Owis
    Zedan, Mohamed Hamdallah
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (04): : 1014 - 1021
  • [29] On the Utility of Quantitative Diffusion-Weighted MR Imaging as a Tool in Differentiation between Malignant and Benign Thyroid Nodules
    Wu, Lian-Ming
    Chen, Xiao-Xi
    Li, Yu-Lai
    Hua, Jia
    Chen, Jie
    Hu, Jiani
    Xu, Jian-Rong
    ACADEMIC RADIOLOGY, 2014, 21 (03) : 355 - 363
  • [30] Vascular flow a predictor of malignant thyroid nodules: a meta-analysis
    Khadra, Helmi
    Bakeer, Mohamed
    Hu, Tian
    Kandil, Emad
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (04) : E87 - E88