Fast pulmonary contour extraction in X-Ray CT images: A methodology and quality assessment

被引:24
|
作者
Silva, A [1 ]
Silva, JS [1 ]
Santos, BS [1 ]
Ferreira, C [1 ]
机构
[1] Univ Aveiro, DET, IEETA, P-3800 Aveiro, Portugal
关键词
image analysis; segmentation; Computed Tomography; pulmonary contours; quantitative evaluation; non-parametric statistics;
D O I
10.1117/12.428139
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Segmentation of thoracic X-Ray Computed Tomography images is a mandatory pre-processing step in many automated or semi-automated analysis tasks such us region identification, densitometric analysis, or even for 3D visualization purposes when a stack of slices has to be prepared for surface or volume rendering. In this work, we present a fully automated and fast method for pulmonary contour extraction and region identification. Our method combines adaptive intensity discrimination, geometrical feature estimation and morphological processing resulting into a fast and flexible algorithm. A complementary but not less important objective of this work consisted on a quality assessment study of the developed contour detection technique. The automatically extracted contours were statistically compared to manually drawn pulmonary outlines provided by two, radiologists. Exploratory data analysis and non-parametric statistical tests were performed on the results obtained using several figures of merit. Results indicate that, besides a strong consistence among all the quality indexes, there is a wider inter-observer variability concerning both radiologists than the variability of our algorithm when compared to each one of the radiologists. As an overall conclusion we claim that the consistence and accuracy of our detection method is more than acceptable for most of the quantitative requirements mentioned by the radiologists.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
  • [21] Sensitivity improvement of automatic pulmonary nodules detection in chest X-ray CT images
    Homma N.
    Shimoyama S.
    Ishibashi T.
    Kawazumi Y.
    Yoshizawa M.
    Artificial Life and Robotics, 2010, 15 (4) : 526 - 529
  • [22] Fast ship contour extraction in SAR images
    Nie, Yuan-Ying
    Fan, Shu-Chen
    Shui, Peng-Lang
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (19): : 5885 - 5888
  • [23] X-ray techniques for quality assessment
    Andersen, K
    QUALITY OF FISH FROM CATCH TO CONSUMER: LABELLING, MONITORING AND TRACEABILITY, 2003, : 283 - 286
  • [24] A FAST METHOD FOR SPINE LOCALIZATION IN X-RAY IMAGES
    Huang, Chao-Hui
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 5091 - 5094
  • [25] Feature Extraction in X-ray Images for Hazelnuts Classification
    Khosa, Ikramullah
    Pasero, Eros
    PROCEEDINGS OF THE 2014 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2014, : 2354 - 2360
  • [26] A Review on CT and X-Ray Images Denoising Methods
    Dang N H Thanh
    Prasath, V. B. Surya
    Le Minh Hieu
    INFORMATICA-AN INTERNATIONAL JOURNAL OF COMPUTING AND INFORMATICS, 2019, 43 (02): : 151 - 159
  • [27] Knot Detection in X-Ray CT Images of Wood
    Kraehenbuehl, A.
    Kerautret, B.
    Debled-Rennesson, I.
    Longuetaud, F.
    Mothe, F.
    ADVANCES IN VISUAL COMPUTING, ISVC 2012, PT II, 2012, 7432 : 209 - 218
  • [28] Accurate lung segmentation for X-ray CT images
    Gao, Qixin
    Wang, ShengJun
    Zhao, Dazhe
    Liu, Jiren
    ICNC 2007: THIRD INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, VOL 2, PROCEEDINGS, 2007, : 275 - +
  • [29] Pulmonary X-Ray Images. A Fractal Analysis
    Nichita, Mihai-Virgil
    Paun, Maria-Alexandra
    Paun, Vladimir-Alexandru
    Paun, Viorel-Puiu
    TIM 19 PHYSICS CONFERENCE, 2020, 2218
  • [30] Fast algorithm for fluorescent x-ray CT reconstruction
    Yuasa, T
    Takeda, T
    Dilmanian, FA
    Akiba, M
    Hyodo, K
    Akatsuka, T
    Itai, Y
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 863 - 866