Detection of drugs in urine by ambient direct ionization mass spectrometry

被引:3
|
作者
Xiong Shiling [1 ]
Hong Huanhuan [1 ,2 ]
Wen Luhong [1 ,2 ]
Hu Shundi [1 ,2 ]
Chen Anqi [1 ,2 ]
Xiong Wei [1 ,2 ]
Chen La [1 ,2 ]
机构
[1] Ningbo Univ, Res Inst Adv Technol, Ningbo 315211, Peoples R China
[2] China Innovat Instrument Co Ltd, Ningbo 315100, Peoples R China
关键词
ambient direct ionization; portable mass spectrometer; drug; urine; rapid detection; RAPID DETECTION; SULFONAMIDES;
D O I
10.3724/SP.J.1123.2022.01013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
According to the Report of Drug Situation in China (2020), the growth rate of the number of drug abusers in China has decreased, but the number of drug abusers is still large. An efficient screening method is necessary for controlling drug abuse. As an important type of biological sample, urine is widely used for the rapid screening of drug addicts. However, because of the complex composition, low content, and strong interference from the body' s metabolism, the detection of drugs in urine remains a challenge. Traditional rapid screening techniques such as immunocolloidal gold analysis have a high false positive rate and insufficient quantitative capability. In addition, laboratory mass spectrometry methods require complicated time. consuming sample pre. processing and strict environmental conditions, and hence, are un. suitable for on. site rapid analysis. In recent years, various direct ionization mass spectrometry techniques such as direct analysis in real time (DART), desorption electrospray ionization (DESI), and dielectric barrier discharge ionization (DBDI) have advanced rapidly. These tech. niques have been applied to public safety, food safety, environmental detection, etc. In con. trast to traditional ionization mass spectrometry methods, these direct ionization techniques allow for the in situ analysis of samples with simple or no pretreatment; moreover, they have the advantages of high analytical efficiency and sensitivity. In particular, pulsed electrospray ionization has the characteristics of less sample demand, compact, lightweight equipment, and no carrier gas. This paper presents a rapid method based on pulsed electrospray ionization mass spectrometry for the detection of urine samples. A rapid detection platform comprising a probe electrospray ionization source, a portable linear ion trap mass spectrometer (MS), and their coupling interface is adopted. The probe electrospray ion source includes a conducting metal wire, plastic handle, and silica glass capillary, whose tip has an inner diameter of 50 mu m. The guide rail at the coupling interface is used to align the probe with the sample inlet of the porta. ble mass spectrometer and maintain a distance of 10 mm between the probe tip and the sample inlet of the MS. The spray voltage of the probe electrospray ion source and the temperature of the MS inlet capillary are optimized at 1.8 kV and 205 degrees C, respectively. In addition, rapid and efficient pretreatment techniques for urine samples have been developed. Buffer salts used for pH regulation and liquid.liquid extraction based on ethyl acetate were adopted for the pretreat. ment process. The linearity of the detection ability and the linear ranges of various drug.spiked solutions were also investigated. The results showed that the correlation coefficients for the quantitative detection of methamphetamine, ketamine, methylenedioxymethamphetamine (MDMA), and cocaine were greater than 0.99 at concentrations ranging from 1 to 100 ng / mL. Moreover, the limits of detection (LODs) for the five conventional drug. spiked urine were 0.5-30 ng / mL. The spiked recoveries ranged from 56.1% to 103.7%, with relative standard devia. tions (RSDs) of 9.0% - 27.8%, implying that the combination of the instruments and the pre. treatment method can lead to good accuracy. To validate the performance of the rapid detection method, 40 positive and 110 negative urine samples were tested and analyzed. The overall accu. racy was over 99%, and the five conventional drugs in urine samples could be detected within 20 s. The research findings of this work could promote the development of rapid detection tech. nology, accelerate the popularization and application of ambient direct ionization mass spec. trometry, and improve the services of on. site law enforcement.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 19 条
  • [1] Influence of Inlet Capillary Temperature on the Microdroplet Chemistry Studied by Mass Spectrometry
    Banerjee, Shibdas
    Zare, Richard N.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 2019, 123 (36): : 7704 - 7709
  • [2] Practical implications of some recent studies in electrospray ionization fundamentals
    Cech, NB
    Enke, CG
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (06) : 362 - 387
  • [3] [陈思媛 Chen Siyuan], 2017, [应用化工, Applied Chemical Industry], V46, P2441
  • [4] Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current ElectroSpray Ionization Tandem Mass Spectrometry
    Fu, Xian
    Liang, Hengxing
    Xia, Bing
    Huang, Chunyan
    Ji, Baocheng
    Zhou, Yan
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (37) : 8256 - 8263
  • [5] Rapid Detection of Medicine Based on New Dielectric Barrier Discharge Ionization Mass Spectrometry
    Hong Huan-Huan
    Zhao Peng
    Ning Lu-Sheng
    Wen Lu-Hong
    Xu Tie-Feng
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (10) : 1529 - 1534
  • [6] ELECTROSPRAY: FROM IONS IN SOLUTION TO IONS IN THE GAS PHASE, WHAT WE KNOW NOW
    Kebarle, Paul
    Verkerk, Udo H.
    [J]. MASS SPECTROMETRY REVIEWS, 2009, 28 (06) : 898 - 917
  • [7] Li P, 2015, FORENSIC SCI TECHNOL, V40, P305
  • [8] [梁晨 Liang Chen], 2010, [质谱学报, Journal of Chinese Mass Spectrometry Society], V31, P224
  • [9] 解吸电喷雾电离质谱技术在天然药物分析中的应用进展
    刘龙婵
    李依璠
    张方丽
    李林楠
    王峥涛
    杨莉
    [J]. 药学学报, 2021, (08) : 2204 - 2216
  • [10] [Liu Min 刘敏], 2021, [分析测试学报, Journal of Instrumental Analysis], V40, P171