Magnetic core-shell fluorescent pH ratiometric nanosensor using a Stober coating method

被引:24
|
作者
Lapresta-Fernandez, A. [1 ,2 ]
Doussineau, T. [2 ,3 ]
Moro, A. J. [2 ,4 ]
Dutz, S. [5 ]
Steiniger, F. [6 ]
Mohr, G. J. [7 ]
机构
[1] Univ Seville, CSIC, Ctr Mixto, Inst Ciencia Mat Sevilla, Seville 41092, Spain
[2] Univ Jena, Inst Phys Chem, D-07743 Jena, Germany
[3] Univ Lyon 1, CNRS, UMR 5579, LASIM, F-69622 Villeurbanne, France
[4] Univ Nova Lisboa, Fac Ciencias & Tecnol, Dept Quim, REQUIMTE, P-2829516 Caparica, Portugal
[5] Inst Photon Technol, Dept Nano Biophoton, Jena, Germany
[6] Fac Med, Ctr Electron Microscopy, Jena, Germany
[7] Fraunhofer Res Inst Modular Solid State Technol, Dept Polytron Syst, Workgrp Sensor Mat, D-93053 Regensburg, Germany
关键词
Nanosensor; Stober method; Iron oxide nanoparticles; Fluorescence; Ratiometric pH measurements; DOPED SILICA NANOPARTICLES; IRON-OXIDE NANOPARTICLES; SINGLE LIVING CELLS; POLYMER NANOPARTICLES; OPTICAL NANOSENSORS; CHEMICAL-ANALYSIS; PEBBLE SENSORS; DELIVERY; FUNCTIONALIZATION; NANOCOMPOSITES;
D O I
10.1016/j.aca.2011.09.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the use of a modified Stober method for coating maghemite (gamma-Fe2O3) nanocrystals with silica shells in order to built magnetic fluorescent sensor nanoparticles in the 50-70 nm diameter range. In detail, the magnetic cores were coated by two successive silica shells embedding two fluorophores (two different silylated dye derivatives), which allows for ratiometric pH-measurements in the pH range 5-8. Silica coated magnetic nanoparticles were prepared using maghemite nanocrystals as cores (5-10 nm in diameter) coated by tetraethoxyorthosilicate via hydrolysis/condensation in ethanol, catalyzed by ammonia. In the inner shell was covalently attached a sulforhodamine B, which was used as a reference dye; while a pH-sensitive fluorescein was incorporated into the outer shell. Once synthesized, the particles were characterized in terms of morphology, size, composition and magnetization, using dynamic light scattering (DLS), transmission electron microscopy (TEM), X-ray diffraction (XRD) and vibrating sample magnetometry (VSM). TEM analysis showed the nanoparticles to be very uniform in size. Wide-angle X-ray diffractograms showed, for uncoated as well as coated nanoparticles, typical peaks for the spinel structure of maghemite at the same diffraction angle, with no structural changes after coating. When using VSM, we obtained the magnetization curves of the resulting nanoparticles and the typical magnetization parameters as saturation magnetization (M-s), coercivity (H-c). and remanent magnetization (M-r). The dual-dye doped magnetic-silica nanoparticles showed a satisfactory magnetization that could be suitable for nanoparticle separation and localized concentration of them. Changes in fluorescence intensity of the pH indicator in the different pH buffered solutions were observed within few seconds indicating an easy accessibility of the embedded dye by protons through the pores of the silica shell. The relationship between the ratio in fluorescence (sensor/reference dyes) and pH was adjusted to a sigmoidal fit using a Boltzmann type equation. Finally, the proposed method was statistically validated against a reference procedure using samples of water and physiological buffer with 2% (w/v) of horse serum added, indicating that there are no significant statistical differences at a 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 50 条
  • [1] Magnetic and fluorescent core-shell nanoparticles for ratiometric pH sensing
    Lapresta-Fernandez, Alejandro
    Doussineau, Tristan
    Dutz, Silvio
    Steiniger, Frank
    Moro, Artur J.
    Mohr, Gerhard J.
    NANOTECHNOLOGY, 2011, 22 (41)
  • [2] Ratiometric pH Sensor Based on Fluorescent Core-Shell Nanoparticles
    Atabaev, Timur Sh.
    Vu, Hong Ha Thi
    Hwang, Yoon-Hwae
    Kim, Hyung-Kook
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2017, 17 (11) : 8313 - 8316
  • [3] A fluorescent magnetic core-shell nanosensor for detection of copper ions in natural waters
    Namikuchi, Eliane A.
    Gaspar, Rafael D. L.
    Raimundo Jr, Ivo M.
    Mazali, Italo O.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 300
  • [4] Core-shell type dually fluorescent polymer nanoparticles for ratiometric pH-sensing
    Allard, Emmanuel
    Larpent, Chantal
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2008, 46 (18) : 6206 - 6213
  • [5] An efficient core-shell fluorescent silica nanoprobe for ratiometric fluorescence detection of pH in living cells
    Fu, Jingni
    Ding, Changqin
    Zhu, Anwei
    Tian, Yang
    ANALYST, 2016, 141 (15) : 4766 - 4771
  • [6] Biocompatible fluorescent core-shell nanoparticles for ratiometric oxygen sensing
    Wang, Xiao-Hui
    Peng, Hong-Shang
    Ding, He
    You, Fang-Tian
    Huang, Shi-Hua
    Teng, Feng
    Dong, Biao
    Song, Hong-Wei
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (31) : 16066 - 16071
  • [7] Synthesis of monodisperse fluorescent core-shell silica particles using a modified Stober method for imaging individual particles in dense colloidal suspensions
    Lee, MH
    Beyer, FL
    Furst, EM
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 288 (01) : 114 - 123
  • [8] Uniform multifunctional porous core-shell structures from a simple Stober method
    Li, Wei
    Zhao, Dongyuan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [9] Core-shell polymeric nanoparticles comprising BODIPY and fluorescein as ultra-bright ratiometric fluorescent pH sensors
    Grazon, Chloe
    Si, Yang
    Placial, Jean-Pierre
    Rieger, Jutta
    Meallet-Renault, Rachel
    Clavier, Gilles
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2019, 18 (05) : 1156 - 1165
  • [10] Preparation of novel core-shell silica particles for pH sensing using ratiometric fluorescence approach
    Ye, Ting-xiu
    Du, Yan-yan
    He, Chun-yan
    Qiu, Bin
    Wang, Yi-ru
    Chen, Xi
    ANALYTICAL METHODS, 2012, 4 (04) : 1001 - 1004