Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

被引:13
|
作者
Pang, Yong [1 ]
Xie, Zhentian [1 ]
Li, Ye [1 ]
Xu, Duan [1 ]
Vigneron, Daniel [1 ,2 ,3 ,4 ]
Zhang, Xiaoliang [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] UCSF UC Berkeley Joint Grad Grp Bioengn, San Francisco, CA 94720 USA
[3] UCSF UC Berkeley Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[4] Calif Inst Quantitat Biosci QB3, San Francisco, CA 94158 USA
来源
MATERIALS | 2011年 / 4卷 / 08期
关键词
Finite-Difference Time-Domain; common-mode; microstrip; Magnetic Resonance Imaging; high field; PHASED-ARRAY COIL; BIRDCAGE COIL; SURFACE COIL; HUMAN HEAD; PARALLEL EXCITATION; HUMAN BRAIN; 7; TESLA; DESIGN; MRI; FREQUENCY;
D O I
10.3390/ma4081333
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF) field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintain the homogeneity of the RF field. To investigate the design method, the common-mode resonator was realized by using a microstrip line which was split along the central to become a pair of parallel transmission lines within which common-mode currents exist. Eight common-mode resonators were placed equidistantly along the circumference of a low loss dielectric cylinder to form a volume coil. Theoretical analysis and comparison between the 16-strut common-mode volume coil and a conventional 16-strut volume coil in terms of RF field homogeneity and efficiency was performed using Finite-Difference Time-Domain (FDTD) method at 298.2 MHz. MR imaging experiments were performed by using a prototype of the common-mode volume coil on a whole body 7 Tesla scanner. FDTD simulation results showed the reduced number of resonant modes of the common-mode volume coil over the conventional volume coil, while the RF field homogeneity of the two type volume coils was kept at the same level. MR imaging of a water phantom and a kiwi fruit showing the feasibility of the proposed method for simplifying the volume coil design is also presented.
引用
收藏
页码:1333 / 1344
页数:12
相关论文
共 50 条
  • [21] Ultrahigh field magnetic resonance imaging: new frontiers and possibilities in human imaging
    Zubkov, M. A.
    Andreychenko, A. E.
    Kretov, E., I
    Solomakha, G. A.
    Melchakova, I., V
    Fokin, V. A.
    Simovski, C. R.
    Belov, P. A.
    Slobozhanyuk, A. P.
    PHYSICS-USPEKHI, 2019, 62 (12) : 1214 - 1232
  • [22] Comparison of Submucosal Resection and Radiofrequency Turbinate Volume Reduction for Inferior Turbinate Hypertrophy: Evaluation by Magnetic Resonance Imaging
    Ercan C.
    Imre A.
    Pinar E.
    Erdoğan N.
    Umut Sakarya E.
    Oncel S.
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2014, 66 (3) : 281 - 286
  • [23] Oval gradient coils for an open magnetic resonance imaging system with a vertical magnetic field
    Matsuzawa, Koki
    Abe, Mitsushi
    Kose, Katsumi
    Terada, Yasuhiko
    JOURNAL OF MAGNETIC RESONANCE, 2017, 278 : 51 - 59
  • [24] Trap Design for Insertable Second-Nuclei Radiofrequency Coils for Magnetic Resonance Imaging and Spectroscopy
    Dabirzadeh, Arash
    McDougall, Mary Preston
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (03) : 121 - 132
  • [25] Dual-Channel Transverse Fields Radiofrequency Coils for 1.5 T Magnetic Resonance Imaging
    Giovannetti, Giulio
    Burov, Denis
    Alecci, Marcello
    Rollo, Rocco
    Galante, Angelo
    SENSORS, 2024, 24 (07)
  • [26] Magnetic Resonance Imaging at Ultrahigh Fields
    Ugurbil, Kamil
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (05) : 1364 - 1379
  • [27] REDUCTION OF CORTICAL VOLUME IN SCHIZOPHRENIA ON MAGNETIC-RESONANCE-IMAGING
    HARVEY, I
    RON, MA
    DUBOULAY, G
    WICKS, D
    LEWIS, SW
    MURRAY, RM
    PSYCHOLOGICAL MEDICINE, 1993, 23 (03) : 591 - 604
  • [28] Sodium Radiofrequency Coils for Magnetic Resonance: From Design to Applications
    Giovannetti, Giulio
    Flori, Alessandra
    Martini, Nicola
    Francischello, Roberto
    Aquaro, Giovanni Donato
    Pingitore, Alessandro
    Frijia, Francesca
    ELECTRONICS, 2021, 10 (15)
  • [29] Micro structured planar gradient coils for low field magnetic resonance Imaging
    Ellersiek, Dennis
    Dura, Georg
    Mokwa, Wilfried
    Schnakenberg, Uwe
    Harms, Silke
    Casanova, Federico
    Blftmich, Bernhard
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 896 - 899
  • [30] Multiple slot modules for high field magnetic resonance imaging array coils
    Alkandari, Dheyaa
    Bosshard, John C.
    Huang, Chung-Huan
    Wright, Steven M.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2485 - 2498