In situ measurements of optical film parameters and plasma monitoring during reactive sputtering for advanced in-line process control

被引:3
|
作者
Richter, U. [1 ]
Hentsch, W. [2 ]
Liepack, H. [2 ]
Kruse, R. [3 ]
Dittrich, R. [4 ]
机构
[1] SENTECH Instruments GmbH, D-12489 Berlin, Germany
[2] FHR Anlagenbau GmbH, D-01458 Ottendorf Okrilla, Germany
[3] Steag ETA Opt GmbH, D-52525 Heinsberg, Germany
[4] IfU GmbH, D-09244 Gottfried Schenker, Germany
关键词
inline; ellipsometry; reflectometry; sputtering;
D O I
10.1016/j.tsf.2007.05.094
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work the spectroscopic ellipsometry and the reflectometry/transmission measurements together with an advanced plasma monitor were used for inline measurements. All systems were installed in an inline sputtering equipment which enables a continuous deposition process-the condition for a direct feedback to the deposition parameters. The metrology tools were connected by a framework software which used an XML over TCP/IP connection. The setup allowed to control the multilayer deposition using a deposition script and to use the metrology tools for measuring the thicknesses and to correct the deposition rates. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:4541 / 4545
页数:5
相关论文
共 21 条
  • [1] Dynamic process control of rf reactive sputtering by monitoring plasma emission intensity
    Inoue, S
    Uchida, H
    Ohba, T
    Koterazawa, K
    Chayahara, A
    Terasawa, M
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1997, 61 (10) : 1108 - 1114
  • [2] Optical coherence tomography as a novel tool for in-line monitoring of a pharmaceutical film-coating process
    Markl, Daniel
    Hannesschlaeger, Guenther
    Sacher, Stephan
    Leitner, Michael
    Khinast, Johannes G.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 55 : 58 - 67
  • [3] Process monitoring during AlNxOy deposition by reactive magnetron sputtering and correlation with the film's properties
    Borges, Joel
    Martin, Nicolas
    Vaz, Filipe
    Marques, Luis
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2014, 32 (02):
  • [4] Reflectance infrared spectroscopy for in-line monitoring of nicotine during a coating process for an oral thin film
    Hammes, Florian
    Hille, Thomas
    Kissel, Thomas
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 176 - 182
  • [5] The Efficiency Evaluation of the Reactive Extrusion Process for Polyethylene Terephthalate (PET). Monitoring of the Industrial Foil Manufacturing Process by In-Line Rheological Measurements
    Szymczak, Piotr
    Dziadowiec, Damian
    Andrzejewski, Jacek
    Szostak, Marek
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [6] Ensuring long-term stability of process and film parameters during target lifetime in reactive magnetron sputtering
    Bartzsch, H
    Frach, R
    Goedicke, K
    Böcher, B
    Gottfried, C
    SURFACE & COATINGS TECHNOLOGY, 2002, 150 (01): : 88 - 94
  • [7] In situ optical monitoring and process control: Measuring transmittance and reflectance of optical coatings during deposition
    Gaebler, Johannes
    Stenzel, Olaf
    Wilbrandt, Steffen
    Kaiser, Norbert
    VAKUUM IN FORSCHUNG UND PRAXIS, 2013, 25 (06) : 22 - 28
  • [8] Control of plasma flux composition incident on TiN films during reactive magnetron sputtering and the effect on film microstructure
    Muratore, C
    Walton, SG
    Leonhardt, D
    Fernsler, RF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2006, 24 (01): : 25 - 29
  • [9] Real-time In-situ Plasma Etch Process Monitoring for Sensor Based-Advanced Process Control
    Ahn, Jong Hwan
    Gu, Ja Myong
    Han, Seung-Soo
    Hong, Sang Jeen
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2011, 11 (01) : 1 - 5
  • [10] Development of a Process Analytical Technology (PAT) for in-line monitoring of film thickness and mass of coating materials during a pan coating operation
    Gendre, Claire
    Genty, Muriel
    Boiret, Mathieu
    Julien, Marc
    Meunier, Loic
    Lecoq, Olivier
    Baron, Michel
    Chaminade, Pierre
    Pean, Jean Manuel
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 43 (04) : 244 - 250