Assessment and improvement of the thermal performance of a polycarbonate micro continuous flow polymerase chain reactor (CFPCR)

被引:0
|
作者
Chen, Pin-Chuan [1 ]
Mitchell, Michael W. [1 ]
Nikitopoulos, Dimitris E. [1 ]
Soper, Steven A.
Murphy, Michael C. [1 ]
机构
[1] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
BioMEMS are compact devices that use microfabrication to miniaturize benchtop instrumentation. Due to the requirement for uniform temperature distributions over restricted areas, thermal isolation, and faster heating and cooling rates in a limited space, thermal management is a key to ensuring successful performance of BioMEMS devices. The continuous flow polymerase chain reactor (CFPCR) is a compact BioMEMS device that is used to amplify target DNA fragments using repeated thermal cycling. The temperature distribution on the backside of a micro CFPCR was measured using thermochromic liquid crystals and an infrared camera. In the liquid crystal experiment, the performance of a 5 mm thick polycarbonate micro CFPCR with thin film heaters attached directly to the bottom polycarbonate surface over each temperature zone was studied. Natural convection was used as a cooling mechanism. The temperature distribution in the renaturation zone was dependent on the positions of the feedback thermocouples in each zone. Three different thermocouple configurations were assessed and the liquid crystal images showed that a best case 3.86 degrees C temperature difference across the zone, leading to a 20% amplification efficiency compared to a commercial thermal cycler [5]. The device was modified to improve the temperature distribution: a thinner substrate, 2 trim, reduced the thermal capacitance; grooves were micro-milled in the backside to isolate each temperature zone; and three separate copper heating stages, combining the thin film heaters with copper plates, applied uniform temperatures to each zone [10]. Infrared camera images showed that the temperature distributions were distinct and uniform with a +/- 0.3 degrees C variations in each temperature zone, improving amplification efficiency to 72%. Good thermal management for PCR amplification can't only increase its reliability and yield efficiency, but also accelerate the entire analytical process.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [31] Thermal control of micro reverse transcription-polymerase chain reaction systems
    Tsai, Nan-Chyuan
    Sue, Chung-Yang
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 136 (01) : 178 - 183
  • [32] The improvement of temperature uniformity for polymerase chain reaction chip with a micro-hotplate (Nickel)
    Mao, Chao-Yang
    Chen, Rong-Sheng
    Chen, Yung-Shieng
    ESTC 2006: 1ST ELECTRONICS SYSTEMINTEGRATION TECHNOLOGY CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2006, : 1242 - +
  • [33] Molecular imprinting in hydrogels using reversible addition-fragmentation chain transfer polymerization and continuous flow micro-reactor
    Kadhirvel, Porkodi
    Machado, Carla
    Freitas, Ana
    Oliveira, Tania
    Dias, Rolando C. S.
    Costa, Mario R. P. F. N.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (09) : 1552 - 1564
  • [34] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    WANG ShiYing1 & WANG Wei2
    2 Institute of Microelectronics
    3 National Key Laboratory of Science and Technology on Micro/Nano Fabrication
    Science China(Technological Sciences), 2010, (07) : 1967 - 1972
  • [35] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    WANG ShiYing WANG Wei School of Physics Peking University Beijing China Institute of Microelectronics Peking University Beijing China National Key Laboratory of Science and Technology on MicroNano Fabrication Beijing China
    Science China(Technological Sciences), 2010, 53 (07) : 1967 - 1972
  • [36] Multi-objective optimisation of polymerase chain reaction continuous flow systems
    Foteini Zagklavara
    Peter K. Jimack
    Nikil Kapur
    Osvaldo M. Querin
    Harvey M. Thompson
    Biomedical Microdevices, 2022, 24
  • [37] Performance evaluation of a continuous flow photocatalytic reactor for wastewater treatment
    Mohammad Rezaei
    Fariborz rashidi
    Sayed Javid Royaee
    Morteza Jafarikojour
    Environmental Science and Pollution Research, 2014, 21 : 12505 - 12517
  • [38] Multi-objective optimisation of polymerase chain reaction continuous flow systems
    Zagklavara, Foteini
    Jimack, Peter K.
    Kapur, Nikil
    Querin, Osvaldo M.
    Thompson, Harvey M.
    BIOMEDICAL MICRODEVICES, 2022, 24 (02)
  • [39] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    Wang ShiYing
    Wang Wei
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (07) : 1967 - 1972
  • [40] Kinetic characteristics of continuous flow polymerase chain reaction chip: A numerical investigation
    ShiYing Wang
    Wei Wang
    Science China Technological Sciences, 2010, 53 : 1967 - 1972