Determination of elemental impurities in pharmaceutical products and related matrices by ICP-based methods: a review

被引:79
|
作者
Barin, Juliano S. [1 ]
Mello, Paola A. [2 ]
Mesko, Marcia F. [3 ]
Duarte, Fabio A. [2 ]
Flores, Erico M. M. [2 ]
机构
[1] Univ Fed Santa Maria, Dept Tecnol & Ciencia Alimentos, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[3] Univ Fed Pelotas, Ctr Ciencias Quim Farmaceut & Alimentos, BR-96160000 Pelotas, RS, Brazil
关键词
Determination of elemental impurities; Pharmacopoeia; Atomic spectrometry; Sample preparation; Heavy metals; Pharmaceutical analysis; PLASMA-MASS SPECTROMETRY; ATOMIC-ABSORPTION-SPECTROMETRY; MICROWAVE-INDUCED COMBUSTION; CHEMICAL-VAPOR GENERATION; RAY-FLUORESCENCE TXRF; HYDRIDE GENERATION; SAMPLE PREPARATION; SPECIATION ANALYSIS; OPTICAL-EMISSION; IODINE DETERMINATION;
D O I
10.1007/s00216-016-9471-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Interest in the determination of elemental impurities in pharmaceuticals has increased in recent years because of changes in regulatory requirements and the need for changing or updating the current limit tests recommended in pharmacopeias. Inductively coupled plasma (ICP) optical emission spectrometry and ICP mass spectrometry are suitable alternatives to perform multielemental analysis for this purpose. The main advantages and limitations of these techniques are described, covering the applications reported in the literature in the last 10 years mainly for active pharmaceutical ingredients, raw materials, and pharmaceutical dosage forms. Strategies used for sample preparation, including dissolution in aqueous or organic solvents, extraction, wet digestion and combustion methods are described, as well as direct solid analysis and ICP-based systems applied for speciation analysis. Interferences observed during the analysis of pharmaceutical products using ICP-based methods are discussed. Methods currently recommended by pharmacopeias for elemental impurities are also covered, showing that the use of ICP-based methods could be considered as a trend in the determination of these impurities in pharmaceuticals. However, the development of a general method that is accurate for all elemental impurities and the establishment of an official method are still challenges. In this regard, the main drawbacks and suitable alternatives are discussed.
引用
收藏
页码:4547 / 4566
页数:20
相关论文
共 50 条
  • [31] ICP-MS method development and validation for determination of trace elemental impurities in caustic potash
    Patidar, Rajesh
    Rebary, Babulal
    Bhadu, Gopala Ram
    Patel, Govind
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 454
  • [32] Greening microwave-assisted digestion method using hydrogen peroxide for determination of elemental impurities by ICP-OES in antihypertensive active pharmaceutical ingredients
    Senger, Caroline M.
    Dornelles, Isadora S.
    Queiroz, Jennefer M.
    Mello, Paola A.
    Muller, Edson I.
    Muller, Aline L. H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 238
  • [33] ANALYTICAL METHODS FOR RESIDUAL SOLVENTS DETERMINATION IN PHARMACEUTICAL PRODUCTS
    Grodowska, Katarzyna
    Parczewski, Andrzej
    ACTA POLONIAE PHARMACEUTICA, 2010, 67 (01): : 13 - 26
  • [34] Spectrofluorimetric determination of selected genotoxic impurities in pharmaceutical raw materials and final products
    Shallan, Aliaa, I
    Abdel-Hakim, Ali
    Hammad, Mohamed A.
    Abou El-Alamin, Maha M.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [35] Spectrofluorimetric determination of selected genotoxic impurities in pharmaceutical raw materials and final products
    Aliaa I. Shallan
    Ali Abdel-Hakim
    Mohamed A. Hammad
    Maha M. Abou El-Alamin
    Scientific Reports, 12
  • [36] Measurement Uncertainty Estimation for the Quantitative Determination of Elemental Impurities in Active Pharmaceutical Ingredients Using Microwave Digestion Followed by ICP-OES According to USP and Specifications
    Satyanarayana, G. N., V
    Subrahanyam, S. Bala
    Silpa, N. Y. S.
    Rao, T. N.
    Sharma, M. T.
    Mudiam, M. K. R.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2022, 37 (02): : 269 - 283
  • [37] Erratum to: Analytical methods for determination of new fluoroquinolones in biological matrices and pharmaceutical formulations by liquid chromatography: a review
    Joana Sousa
    Gilberto Alves
    João Abrantes
    Ana Fortuna
    Amílcar Falcão
    Analytical and Bioanalytical Chemistry, 2012, 403 : 1459 - 1459
  • [38] Development and and validation of an ICP-MS method for the determination of elemental impurities in TP-6076 active pharmaceutical ingredient (API) according to USP ⟨232⟩/⟨233⟩
    Chahrour, Osama
    Malone, John
    Collins, Mark
    Salmon, Vrushali
    Greenan, Catherine
    Bombardier, Amy
    Ma, Zhongze
    Dunwoody, Nick
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 84 - 90
  • [39] Determination of age, isotopic ratios, and elemental impurities in nuclear materials by single quadrupole ICP-MS
    A. Serban
    F. Albota
    E. Ionuz
    C. S. Tuta
    M. Virgolici
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 165 - 173
  • [40] Determination of age, isotopic ratios, and elemental impurities in nuclear materials by single quadrupole ICP-MS
    Serban, A.
    Albota, F.
    Ionuz, E.
    Tuta, C. S.
    Virgolici, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (01) : 165 - 173