Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes

被引:104
|
作者
Salimi, A [1 ]
Hallaj, R [1 ]
Khayatian, GR [1 ]
机构
[1] Kurdistan Univ, Fac Sci, Dept Chem, Sanandaj, Iran
关键词
glassy carbon; modified electrode; multiwall carbon nanotubes; morphine; amperometry; codeine;
D O I
10.1002/elan.200403166
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and fast responding sensor for the determination of morphine is described. The multiwall carbon nanotubes immobilize on preheated glassy carbon electrode (5 min at 50 degrees C) by gently rubbing of electrode surface on a filter paper supporting the carbon nanotubes. The results indicated that carbon nanotubes(CNTs) modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for morphine with relatively high sensitivity, stability and long life. Under conditions of cyclic voltammetry, the potential for oxidation of morphine is lowered by approximately 100 mV and the current is enhanced significantly (10 times) in comparison to the bare glassy carbon electrode at wide pH range (2-9). The electrocatalytic behavior is further exploited as a sensitive detection scheme for morphine determination by hydrodynamic amperometry. Under the optimized conditions the calibration plots are linear in the concentration range 0.5-150 mu M with the calculated detection limit (S/N=3) of 0.2 mu M and sensitivity of 10 nA/mu M and a relative standard deviation (RSD) of 2.5% (n=10). The amperometric response is extremely stable, with no loss in sensitivity over a continual 30 min operation. Such attractive ability of multiwall carbon nanotubes (MWCNTs) modified GC electrode, suggests great promise for a morphine amperometric sensor. Finally the ability of the modified electrode was evaluated for simultaneous determination of morphine and codeine.
引用
收藏
页码:873 / 879
页数:7
相关论文
共 50 条
  • [31] Electrochemical determination of diphenols and their mixtures at the multiwall carbon nanotubes/poly (3-methylthiophene) modified glassy carbon electrode
    Zhang, He
    Zhao, Jinsheng
    Liu, Houting
    Liu, Renmin
    Wang, Huaisheng
    Liu, Jifeng
    MICROCHIMICA ACTA, 2010, 169 (3-4) : 277 - 282
  • [32] Electrochemical Behavior and Voltammetric Determination of Chlorpheniramine Maleate by Means of Multiwall Carbon Nanotubes-Modified Glassy Carbon Electrode
    Pourghobadi, Z.
    Pourghobadi, R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09): : 7241 - 7250
  • [33] Electrochemical determination of diphenols and their mixtures at the multiwall carbon nanotubes/poly (3-methylthiophene) modified glassy carbon electrode
    He Zhang
    Jinsheng Zhao
    Houting Liu
    Renmin Liu
    Huaisheng Wang
    Jifeng Liu
    Microchimica Acta, 2010, 169 : 277 - 282
  • [34] Electrooxidation of DNA at glassy carbon electrodes modified with multiwall carbon nanotubes dispersed in chitosan
    Bollo, Soledad
    Ferreyra, Nancy F.
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2007, 19 (7-8) : 833 - 840
  • [35] Electrooxidation of DNA at glassy carbon electrodes modified with multiwall carbon nanotubes dispersed in polyethylenimine
    Luque, Guillermina L.
    Ferreyra, Nancy F.
    Granero, Adrian
    Bollo, Soledad
    Rivas, Gustavo A.
    ELECTROCHIMICA ACTA, 2011, 56 (25) : 9121 - 9126
  • [36] Multi-walled Carbon Nanotubes-Modified Glassy Carbon Electrode for the Detection of Anthracene
    Mwazighe, Fredrick M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11058 - 11069
  • [37] Amperometric Detection of Isoprenaline Based on Glassy Carbon Electrode Modified by Iridium Oxide Nanoparticles
    Roushani, Mahmoud
    Farokhi, Somayeh
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (05) : 1034 - 1042
  • [38] Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2015, 133 : 134 - 141
  • [39] Amperometric xanthine biosensors based on chitosan-Co3O4-multiwall carbon nanotube modified glassy carbon electrode
    Dalkiran, Berna
    Kacar, Ceren
    Erden, Pinar Esra
    Kilic, Esma
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 200 : 83 - 91
  • [40] Amperometric thrombin aptasensor using a glassy carbon electrode modified with polyaniline and multiwalled carbon nanotubes tethered with a thiolated aptamer
    Zhaohong Su
    Xiaolin Xu
    Haitao Xu
    Yi Zhang
    Chaorong Li
    Yan Ma
    Dongcheng Song
    Qingji Xie
    Microchimica Acta, 2017, 184 : 1677 - 1682