Measuring Cranial Vault Volume With Three-Dimensional Photography: A Method of Measurement Comparable to the Gold Standard

被引:65
|
作者
McKay, Douglas R. [1 ]
Davidge, Kristen M. [2 ]
Williams, Susanne K. [3 ]
Ellis, Lloyd A. [3 ]
Chong, David K. [1 ]
Teixeira, Rodrigo P. [1 ]
Greensmith, Andrew L. [1 ]
Holmes, Anthony D. [1 ]
机构
[1] Royal Childrens Hosp, Dept Plast & Maxillofacial Surg, Melbourne, Vic, Australia
[2] Univ Toronto, Dept Plast Surg, Toronto, ON, Canada
[3] Royal Childrens Hosp, Educ Res Ctr, Melbourne, Vic, Australia
关键词
Cranial vault volume; three-dimensional photography; craniosynostosis; INTRACRANIAL VOLUME; SAGITTAL SYNOSTOSIS; CRANIOSYNOSTOSIS; RELIABILITY; RADIATION; PRESSURE; CHILDREN;
D O I
10.1097/SCS.0b013e3181ebe92a
中图分类号
R61 [外科手术学];
学科分类号
摘要
The gold standard for measuring cranial vault volume is a computed tomography (CT) scan. Computed tomography scans in the pediatric population carry the significant risk of inducing a malignancy later in life. In a novel study, we show that a three-dimensional (3D) photograph can be used to measure and track cranial vault volume changes in craniosynostosis patients. In a study of adequate power as determined by pre hoc analysis, we demonstrate a greater than 0.91 correlation coefficient between volume as measured by CT and 3D photograph in more than 70 patients presenting to a tertiary craniofacial center (P<0.001). Volume above a plane running through the lateral canthus (ex) and tragus (t) sag-ex-t on the digital 3D photograph differs from CT by a mean percentage difference of 31.9% (SD, 14.0%; 95% confidence interval, P<0.0001). A linear regression model was used to determine the equation describing the relationship between volume as measured by 3D photograph and CT; with this equation, the absolute volume of the cranial vault is easily determined using only the 3D image. Interrater reliability is high (>0.99, ICC 2,1). The ability to measure cranial vault volume from the 3D photograph adds an important dimension to the complete and objective analysis of skull growth and postoperative change.
引用
收藏
页码:1419 / 1422
页数:4
相关论文
共 50 条
  • [41] Measurement of intracranial translucency using three-dimensional ultrasound and Volume IT™
    Lee, Mi-Young
    Won, Hye-Sung
    Jeong, Ba-Da
    Hyun, Min-Kyung
    Lee, Hee-Young
    Shim, Jae-Yoon
    Lee, Pil-Ryang
    Kim, Ahm
    PRENATAL DIAGNOSIS, 2012, 32 (05) : 472 - 475
  • [42] Three-dimensional ultrasound measurement of cervical lymph node volume
    Ying, M.
    Pang, B. S. F.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (980): : 617 - +
  • [43] Three-dimensional ultrasound for carotid vessel wall volume measurement
    Chen, Ying-An
    Chen, Pei-Ya
    Lin, Shinn-Kuang
    TZU CHI MEDICAL JOURNAL, 2022, 34 (01): : 88 - 94
  • [44] Volume measurement of a cardiac myxomatous lesion with three-dimensional echocardiography
    Demirkol, Sait
    Arslan, Zekeriya
    Balta, Sevket
    Kucuk, Ugur
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (07): : 651 - 651
  • [45] Three-dimensional photography method for phase distribution measurements in bubbly flows
    Song, Qiang
    Luo, Rui
    Yang, Xianyong
    Wang, Zhou
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2001, 41 (10): : 65 - 68
  • [46] Measurement of three-dimensional displacement fields and shape using electronic speckle photography
    Synnergren, P
    OPTICAL ENGINEERING, 1997, 36 (08) : 2302 - 2310
  • [47] Three-Dimensional Echocardiographic Measurement of Left Ventricular Stroke Volume in Children: Comparison with Doppler Method
    P. Acar
    G.R. Marx
    Z. Saliba
    D. Sidi
    J. Kachaner
    Pediatric Cardiology, 2001, 22 : 116 - 120
  • [48] Three-dimensional echocardiographic measurement of left ventricular stroke volume in children: Comparison with Doppler method
    Acar, P
    Marx, GR
    Saliba, Z
    Sidi, D
    Kachaner, J
    PEDIATRIC CARDIOLOGY, 2001, 22 (02) : 116 - 120
  • [49] A new measurement method of three-dimensional laser scanning for the volume of railway tank car (container)
    Zhang Zhipeng
    MEASUREMENT, 2021, 170
  • [50] Fetal volume measurement using three-dimensional Ultrasonography - Comparison of a disk summation and rotational method
    Fenton, Bradford W.
    Kowalik, Jenifer D.
    OBSTETRICS AND GYNECOLOGY, 2006, 107 (04): : 84S - 85S