Measuring Cranial Vault Volume With Three-Dimensional Photography: A Method of Measurement Comparable to the Gold Standard

被引:65
|
作者
McKay, Douglas R. [1 ]
Davidge, Kristen M. [2 ]
Williams, Susanne K. [3 ]
Ellis, Lloyd A. [3 ]
Chong, David K. [1 ]
Teixeira, Rodrigo P. [1 ]
Greensmith, Andrew L. [1 ]
Holmes, Anthony D. [1 ]
机构
[1] Royal Childrens Hosp, Dept Plast & Maxillofacial Surg, Melbourne, Vic, Australia
[2] Univ Toronto, Dept Plast Surg, Toronto, ON, Canada
[3] Royal Childrens Hosp, Educ Res Ctr, Melbourne, Vic, Australia
关键词
Cranial vault volume; three-dimensional photography; craniosynostosis; INTRACRANIAL VOLUME; SAGITTAL SYNOSTOSIS; CRANIOSYNOSTOSIS; RELIABILITY; RADIATION; PRESSURE; CHILDREN;
D O I
10.1097/SCS.0b013e3181ebe92a
中图分类号
R61 [外科手术学];
学科分类号
摘要
The gold standard for measuring cranial vault volume is a computed tomography (CT) scan. Computed tomography scans in the pediatric population carry the significant risk of inducing a malignancy later in life. In a novel study, we show that a three-dimensional (3D) photograph can be used to measure and track cranial vault volume changes in craniosynostosis patients. In a study of adequate power as determined by pre hoc analysis, we demonstrate a greater than 0.91 correlation coefficient between volume as measured by CT and 3D photograph in more than 70 patients presenting to a tertiary craniofacial center (P<0.001). Volume above a plane running through the lateral canthus (ex) and tragus (t) sag-ex-t on the digital 3D photograph differs from CT by a mean percentage difference of 31.9% (SD, 14.0%; 95% confidence interval, P<0.0001). A linear regression model was used to determine the equation describing the relationship between volume as measured by 3D photograph and CT; with this equation, the absolute volume of the cranial vault is easily determined using only the 3D image. Interrater reliability is high (>0.99, ICC 2,1). The ability to measure cranial vault volume from the 3D photograph adds an important dimension to the complete and objective analysis of skull growth and postoperative change.
引用
收藏
页码:1419 / 1422
页数:4
相关论文
共 50 条
  • [1] Objectification of cranial vault correction for craniosynostosis by three-dimensional photography
    Wilbrand, Jan-Falco
    Szczukowski, Alexander
    Blecher, Joerg-Christoph
    Pons-Kuehnemann, Joern
    Christophis, Petros
    Howaldt, Hans-Peter
    Schaaf, Heidrun
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) : 726 - 730
  • [2] Automated Measurement of Intracranial Volume Using Three-Dimensional Photography
    Tu, Liyun
    Porras, Antonio R.
    Enquobahrie, Andinet
    Buck, Graham C.
    Tsering, Deki
    Horvath, Samantha
    Keating, Robert
    Oh, Albert K.
    Rogers, Gary F.
    George Linguraru, Marius
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (03) : 314E - 323E
  • [3] Discussion: Automated Measurement of Intracranial Volume Using Three-Dimensional Photography
    Taylor, Jesse A.
    Shakir, Sameer
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (03) : 324E - 325E
  • [4] Three-dimensional versus two-dimensional ultrasound measurement of follicular volume: are they comparable?
    Ahmed Amer
    Mohamad Eid Hammadeh
    Mohamed Kolkailah
    Abdel-Al Ghandour
    Archives of Gynecology and Obstetrics, 2003, 268 (3) : 155 - 157
  • [5] Three-dimensional volume measurement
    Schwartz, G
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 4 - 5
  • [6] Three-dimensional shape measurement of strawberries by volume intersection method
    Imou, K
    Kaizu, Y
    Morita, M
    Yokoyama, S
    TRANSACTIONS OF THE ASABE, 2006, 49 (02): : 449 - 456
  • [7] Three-Dimensional Reconstruction Volume: A Novel Method for Volume Measurement in Kidney Cancer
    Durso, Timothy A.
    Carnell, Jonathan
    Turk, Thomas T.
    Gupta, Gopal N.
    JOURNAL OF ENDOUROLOGY, 2014, 28 (06) : 745 - 750
  • [8] Three-dimensional measurement method of structured light based on three measuring triangles
    Liu, Zhao
    Zhou, Changhe
    Li, Chao
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS VIII, 2018, 10818
  • [9] A Standard Three-dimensional Imaging Protocol Must Be Established for Breast Volume Measurement
    Wang, Chenglong
    Liu, Chunjun
    AESTHETIC PLASTIC SURGERY, 2019, 43 (02) : 556 - 556
  • [10] A Standard Three-dimensional Imaging Protocol Must Be Established for Breast Volume Measurement
    Chenglong Wang
    Chunjun Liu
    Aesthetic Plastic Surgery, 2019, 43 : 556 - 556