Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1

被引:10
|
作者
Mack, A
Mack, G
Scheib, S
Czempiel, H
Kreiner, HJ
Lomax, NJ
Gianolini, S
Rieker, M
Weltz, D
Wolff, R
Muacevic, A
Wowra, B
Böttcher, HD
Seifert, V
机构
[1] GKF GmbH, Gamma Knife Zentrum, DE-60528 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Radiotherapy, Frankfurt, Germany
[3] Univ Hosp Frankfurt, Dept Neurosurg, Frankfurt, Germany
[4] Univ Tubingen, Dept Expt Phys, Tubingen, Germany
[5] PTGR GmbH, Tubingen, Germany
[6] GKS GmbH, Munich, Germany
[7] Univ Hosp Munich, Dept Neurosurg, Munich, Germany
[8] Gamma Knife Ctr Munich, Munich, Germany
[9] Klin Pk, Dept Med Radiat Phys, Zurich, Switzerland
关键词
quality assurance; stereotactic radiosurgery; sterotactic radiotherapy; system test; DIN; 6875-1;
D O I
10.1159/000083175
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The new DIN (' Deutsche Industrie- Norm') 6875- 1, which is currently being finalised, deals with quality assurance ( QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/ radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4- mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in- house, the use of commercially available tools facilitated the QA according to the DIN 6875- 1 with which our results complied. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 50 条
  • [21] A quality assurance program for stereotactic radiosurgery using a miniature multileaf collimator
    Kim, CS
    Schella, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1343 - 1343
  • [22] Stereotactic radiosurgery in India: A nationwide survey of technology and quality assurance practices
    Patwe, Parimal T.
    Deshpande, Sudesh
    Chaudhari, Suresh
    Mahajan, Gajanan R.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (03) : 1013 - 1019
  • [23] Automated Quality Assurance Test for MLC-Based Stereotactic Radiosurgery
    Mamalui-Hunter, M.
    Drzymala, R.
    Low, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [24] Quality Assurance for GammaPod: A Novel Dedicated Breast Stereotactic Radiosurgery Device
    Becker, S.
    Niu, Y.
    Mutaf, Y.
    Prado, K.
    Yu, C.
    Yi, B.
    MEDICAL PHYSICS, 2017, 44 (06) : 2950 - 2950
  • [25] A quality assurance program in stereotactic radiosurgery using the gamma knife unit
    Stuecklschweiger, GE
    Feichtinger, K
    STRAHLENTHERAPIE UND ONKOLOGIE, 1998, 174 : 43 - 46
  • [26] Comparison of Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy of Acoustic Neurinomas According to 3-D Tumor Volume Shrinkage and Quality of Life
    Henzel, Martin
    Hamm, Klaus
    Sitter, Helmut
    Gross, Markus W.
    Surber, Gunnar
    Kleinert, Gabriele
    Engenhart-Cabillic, Rita
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (09) : 567 - 573
  • [27] Machine-related quality assurance in extracranial stereotactic radiotherapy
    Blank, H.
    Csere, P.
    Geyer, P.
    Alheit, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 125 - 126
  • [28] Comparison of quality of life - after stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic schwannomas
    Henzel, M.
    Hamm, K.
    Sitter, H.
    Surber, G.
    Kleinert, G.
    Gross, M. W.
    Engenhart-Cabillic, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 75 - 75
  • [29] Evaluation of a novel patient-specific quality assurance phantom for robotic single-isocentre, multiple-target stereotactic radiosurgery, and stereotactic radiotherapy
    Xu, Qianyi
    Vinogradskiy, Yevgeniy
    Grimm, Jimm
    Nie, Wei
    Dupre, Pamela
    Chawla, Ashish K.
    Bajaj, Gopal
    Yang, Haihua
    Lacouture, Tamara
    Fan, Jiajin
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1155): : 660 - 667
  • [30] Quality Assurance of Image-Guidance for Pediatric Patients in Frameless Stereotactic Radiosurgery
    Dieterich, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S786 - S787