Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1

被引:10
|
作者
Mack, A
Mack, G
Scheib, S
Czempiel, H
Kreiner, HJ
Lomax, NJ
Gianolini, S
Rieker, M
Weltz, D
Wolff, R
Muacevic, A
Wowra, B
Böttcher, HD
Seifert, V
机构
[1] GKF GmbH, Gamma Knife Zentrum, DE-60528 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Radiotherapy, Frankfurt, Germany
[3] Univ Hosp Frankfurt, Dept Neurosurg, Frankfurt, Germany
[4] Univ Tubingen, Dept Expt Phys, Tubingen, Germany
[5] PTGR GmbH, Tubingen, Germany
[6] GKS GmbH, Munich, Germany
[7] Univ Hosp Munich, Dept Neurosurg, Munich, Germany
[8] Gamma Knife Ctr Munich, Munich, Germany
[9] Klin Pk, Dept Med Radiat Phys, Zurich, Switzerland
关键词
quality assurance; stereotactic radiosurgery; sterotactic radiotherapy; system test; DIN; 6875-1;
D O I
10.1159/000083175
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The new DIN (' Deutsche Industrie- Norm') 6875- 1, which is currently being finalised, deals with quality assurance ( QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/ radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4- mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in- house, the use of commercially available tools facilitated the QA according to the DIN 6875- 1 with which our results complied. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 50 条
  • [1] Quality assurance in stereotactic radiosurgery and fractionated stereotactic radiotherapy
    Solberg, T.
    Shepard, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2513 - 2514
  • [2] Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy
    Shepard, D.
    Solberg, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy
    Shepard, D.
    Solberg, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Clearance assurance for stereotactic radiosurgery and radiotherapy
    Furhang, EE
    Hanley, J
    Chiu-Tsao, ST
    Toner, S
    Fan, P
    Gliedman, P
    Harrison, LB
    MEDICAL PHYSICS, 2002, 29 (01) : 45 - 50
  • [5] Quality assurance in stereotactic radiosurgery (QUASIR)
    Mack, A
    Scheib, S
    Weltz, D
    Czempiel, H
    Kreiner, HJ
    Mack, G
    MEDICAL PHYSICS, 2003, 30 (06) : 1522 - 1522
  • [6] Quality Assurance in Stereotactic Radiosurgery (QUASIR)
    Mack, A
    Scheib, S
    Weltz, D
    Czempiel, H
    Kreiner, HJ
    Mack, G
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S50 - S50
  • [7] Comprehensive quality assurance for stereotactic radiosurgery treatments
    Ramaseshan, R
    Heydarian, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14): : N199 - N205
  • [8] MRI quality assurance for gamma knife stereotactic radiosurgery
    Damyanovich, A. Z.
    Zhang, B.
    Mikulis, D.
    Bissonnette, J-P.
    Bernstein, M.
    Menard, C.
    Jaffray, D. A.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S2 - S2
  • [9] Evaluation of Delivery Quality Assurance of Cyberknife Stereotactic Radiosurgery
    Li, J.
    Zhang, X.
    Zhuang, H.
    Yang, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Development and evaluation of quality assurance phantom for stereotactic radiosurgery
    Park, Soah
    Yoon, Jai-Woong
    Kim, Me young
    Cheong, Kwang-Ho
    Kang, Sei-Kwon
    Kim, Kyoung Ju
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (06) : 488 - 495