Navigated reduction for transverse fracture of the acetabulum.: A precision analysis

被引:0
|
作者
Hüfner, T
Citak, M
Tarte, S
Gänsslen, A
Pohlemann, T
Geerling, J
Krettek, C
机构
[1] Hannover Med Sch, Unfallchirurg Klin, D-30625 Hannover, Germany
[2] Maurice Muller Inst Biomech, Bern, Switzerland
[3] Univ Saarland, Abt Unfallchirurg, D-66421 Homburg, Germany
来源
UNFALLCHIRURG | 2003年 / 106卷 / 11期
关键词
acetabulum; fracture; navigation; reduction; laboratory;
D O I
10.1007/s00113-003-0679-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Up to now navigated reduction control based on computed tomography (CT) image data could not be used commercially. With newly developed software, a transverse fracture of the acetabulum was reduced with navigation control in a laboratory test. The results were compared to visual and tactile control in a foam pelvis and specimen. Measurements were done with another magnet-based navigation system. The residual dislocation was measured with translation (mm) and rotation (degrees). Compared with visually controlled reduction, navigated reduction led to a residual dislocation of 0.7 mm and 0.9degrees. Navigated reduction based on CT image data is also accurate for reduction of joint fractures under laboratory conditions. Further improvements of the software are planned for later in vivo use.
引用
收藏
页码:968 / 974
页数:7
相关论文
共 50 条
  • [21] Precision control in surgical procedures: Force feedback control technology for fracture reduction robots
    Ma, Ping
    Miao, Gen-yuan
    Zhang, Qin-He
    Bi, Jian-Ping
    ASIAN JOURNAL OF SURGERY, 2025, 48 (02) : 1083 - 1084
  • [22] Finite Element Analysis of Postoperative Stability of Transverse Scaphoid Waist Fracture
    Srivastav, Ayush
    Behera, Prateek
    Dwivedi, Ravi Kumar
    Santoshi, John Ashutosh
    INDIAN JOURNAL OF ORTHOPAEDICS, 2024, 58 (06) : 785 - 793
  • [23] Open reduction and posterior instrumentation of Type 3 high transverse sacral fracture-dislocation
    Starantzis, Konstantinos A.
    Mirzashahi, Babak
    Behrbalk, Eyal
    Sadat, Mirmostafa
    Shafafy, Masood
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 21 (02) : 286 - 291
  • [24] Precision of Ci-navigated extension and flexion gap balancing in total knee arthroplasty and analysis of potential predictive variables
    Fickert, S.
    Jawhar, A.
    Sunil, P.
    Scharf, H. -P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (04) : 565 - 574
  • [25] Analysis of lens fracture in precision glass molding with the finite element method
    Liu, Yue
    Xing, Yintian
    Li, Chuang
    Yang, Chao
    Xue, Changxi
    APPLIED OPTICS, 2021, 60 (26) : 8022 - 8030
  • [26] Precision of Ci-navigated extension and flexion gap balancing in total knee arthroplasty and analysis of potential predictive variables
    S. Fickert
    A. Jawhar
    P. Sunil
    H.-P Scharf
    Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 565 - 574
  • [27] Precision reduction of femoral neck fractures: a novel strategy based on the femoral neck fracture morphology
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Lin, Fengfei
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [28] Atomic analysis of cleavage fracture in nickel crystal under tension with transverse constraint
    Yashiro, Kisaragi
    Kitamura, Takayuki
    Ohtani, Ryuichi
    Nippon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 1997, 63 (615): : 2380 - 2386
  • [29] Biomechanical Analysis of a Transverse Olecranon Fracture Model Using Tension Band Wiring
    Hammond, James
    Ruland, Robert
    Hogan, Christopher
    Rose, David
    Belkoff, Stephen
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (12): : 2506 - 2511
  • [30] DYNAMIC FRACTURE-ANALYSIS OF A TRANSVERSE WEDGE-LOADED COMPACT SPECIMEN
    URABE, Y
    FUNADA, T
    HOJO, K
    BABA, K
    NUCLEAR ENGINEERING AND DESIGN, 1986, 94 (03) : 291 - 296