摘要
Introduction The pad test is an assessment tool for urinary incontinence (UI) severity classification and therapeutic response monitoring. However, the reliability and reproducibility of this test have been questioned. Objectives To summarize the evidence regarding the accuracy measures and reproducibility of different pad test protocols for assessing UI. Methods A systematic review of the diagnostic accuracy of this tool was performed (CRD42020219392). Eligibility criteria: Studies reporting data on the accuracy measures and reproducibility of the pad test when used for detecting UI in adult men and women. Data sources: MEDLINE, Science Direct, Cochrane, Web of Science, LILACS, and Pedro. Data extraction and synthesis: Two reviewers independently screened the articles, extracted the data, and evaluated the risk of bias (RoB) using the QUADAS-2 tool. Results From 1048 studies, 18 studies were included. Eight of these reported accuracy data, and 12 reported reproducibility properties. A total of 1070 individuals were analyzed, whose mean age ranged from 20 to 90 years. The accuracy of the long-duration protocols was generally moderate to high (sensitivity, 60%-93%; specificity, 60%-84%). The 1-h protocols obtained higher accuracy values. The overall reproducibility was moderate to high (kappa >= 0.66). Limitations The RoB was high and, due to different cutoff points adopted by studies, the bivariate model was not satisfied to perform a meta-analysis. Discussion The 1-h pad test was more accurate but less reproducible when compared to the long-duration tests. Pad test results should be used with caution in clinical practice.
引用
收藏
页码:696 / 709
页数:14
相关论文
共 50 条
  • [21] The diagnostic test accuracy of rectal examination for prostate cancer diagnosis in symptomatic patients: a systematic review
    Daniel Jones
    Charlotte Friend
    Andreas Dreher
    Victoria Allgar
    Una Macleod
    BMC Family Practice, 19
  • [22] Systematic Reviews of Diagnostic Test Accuracy
    Leeflang, Mariska M. G.
    Deeks, Jonathan J.
    Gatsonis, Constantine
    Bossuyt, Patrick M. M.
    ANNALS OF INTERNAL MEDICINE, 2008, 149 (12) : 889 - +
  • [23] PAD TEST WITH FIXED BLADDER VOLUME IN URINARY STRESS-INCONTINENCE
    KINN, AC
    LARSSON, B
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1987, 66 (04) : 369 - 371
  • [24] PAD WEIGHING TEST - A SIMPLE METHOD TO QUANTITATE URINARY-INCONTINENCE
    VICTOR, A
    ANNALS OF MEDICINE, 1990, 22 (06) : 443 - 447
  • [25] 1-hour pad test has low predictive value in the diagnosis of women with urinary incontinence
    Lazzeri, Massimo
    Costantini, Elisabetta
    Giannantoni, Antonella
    Del Zingaro, Michele
    Bini, Vittorio
    Porena, Massimo
    JOURNAL OF UROLOGY, 2008, 179 (04): : 512 - 512
  • [26] ONE-HOUR WARD TEST VS 24-HOUR HOME PAD WEIGHING TEST IN THE DIAGNOSIS OF URINARY-INCONTINENCE
    THIND, P
    GERSTENBERG, TC
    NEUROUROLOGY AND URODYNAMICS, 1991, 10 (03) : 241 - 245
  • [27] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [28] Diagnostic Test Accuracy of Genetic Tests in Diagnosing Psoriasis: A Systematic Review
    Mirghani, Hyder
    Alharfy, Abdulrahman Arshed N.
    Alanazi, Abeer Mohammed M.
    Aljohani, Jomanah Khalid M.
    Aljohani, Raghad Abdulrahman A.
    Albalawi, Raghad Hamdan A.
    Aljohani, Raneem Abdulrahman A.
    Albalawi, Danah Mohsen Alqasmi
    Albalawi, Rahaf Hamdan A.
    Mostafa, Mohamed, I
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [29] Molecular Tools for Diagnosis of Visceral Leishmaniasis: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy
    de Ruiter, C. M.
    van der Veer, C.
    Leeflang, M. M. G.
    Deborggraeve, S.
    Lucas, C.
    Adams, E. R.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (09) : 3147 - 3155
  • [30] Comparison of 20-minute pad test versus 1-hour pad test in women with stress urinary incontinence
    Wu, Wen-Yih
    Sheu, Bor-Ching
    Lin, Ho-Hsiung
    UROLOGY, 2006, 68 (04) : 764 - 768