Thermal performance of a pump-driven loop heat pipe as an air-to-air energy recovery device

被引:27
|
作者
Zhou, Feng [1 ]
Duan, Wei [1 ]
Ma, Guoyuan [1 ]
机构
[1] Beijing Univ Technol, Coll Environm & Energy Engn, Beijing 100124, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Pump; Loop heat pipe; Energy recovery; Refrigerant; Mass flow rate; COOLING LOOP; DATA CENTERS; SYSTEM; EXCHANGERS;
D O I
10.1016/j.enbuild.2017.06.057
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A pump-driven loop heat pipe (PLHP) was proposed for energy recovery from exhaust air to reduce fresh air handling energy consumption of air conditioning systems. The influences of working fluid, mass flow rate, heat exchanging area and facing air velocity on heat transfer capacity, temperature effectiveness and coefficient of performance (COP) were studied experimentally under different working conditions. The optimum working fluid and value were obtained, respectively. Results indicate that the heat transfer capacity and COP increase with the temperature difference between indoor and outdoor air while the temperature effectiveness decreases. The general performance for R32 as working fluid was better than R22 and R152a. For summer condition, the heat transfer capacity was 4.09 kW and the COP was 9.26 when the mass flow rate was 250 kg h(-1), the heat exchanging area was 58.0 m(2) and the facing air velocity was 1.8 ms(-1). For winter condition, the heat transfer capacity was 6.63 kW and the COP was 14.20 while the mass flow rate was 300 kg h(-1), the heat exchanging area was 58.0 m(2) and the facing air velocity was 1.8 m s(-1). The tested device could meet the energy recovery need with remarkable energy savings. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 216
页数:11
相关论文
共 50 条
  • [41] MODELING AND CONTROL OF AN AIR-TO-AIR HEAT-RECOVERY SYSTEM
    ZAHEERUDDIN, M
    WANG, JCY
    HEAT RECOVERY SYSTEMS & CHP, 1994, 14 (02): : 143 - 152
  • [42] Enhancing the performance of a greenhouse dryer with natural dolomite powder-embedded latent heat thermal energy storage unit and air-to-air heat recovery system
    Selimefendigil, Fatih
    Sirin, Ceylin
    SOLAR ENERGY, 2023, 262
  • [43] PRACTICAL THERMAL DESIGN OF RUN-AROUND AIR-TO-AIR HEAT-RECOVERY SYSTEM
    WANG, JCY
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1985, 5 (06): : 493 - 501
  • [44] AIR-TO-AIR HEAT-RECOVERY SYSTEMS FOR RESEARCH LABORATORIES
    CARNES, L
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1984, 26 (05): : 56 - 56
  • [45] Design of heat pump-driven liquid desiccant air conditioning systems for residential building
    Lee, Jae-Hee
    Ko, Jin-Young
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2021, 183
  • [46] Dynamic modeling of an integrated air-to-air heat pump using Modelica
    Mortada, S.
    Zoughaib, A.
    Clodic, D.
    Arzano-Daurelle, C.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (05): : 1335 - 1348
  • [47] Transient mass flow rate of a residential air-to-air heat pump
    Belth, M.I.
    Grzymala, T.E.
    Tree, D.R.
    International Journal of Refrigeration, 1988, 11 (05) : 298 - 304
  • [48] Thermal performance of a fixed-plate air-to-air energy recovery system for building application in hot and humid environment
    Mansur, Fatin Zafirah
    Keling, Nor Amalin
    Ang, Jia Hui
    Salehabadi, Ali
    Riffat, Saffa
    Yusup, Yusri
    Ahmad, Mardiana Idayu
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (06) : 8900 - 8918
  • [49] Comparison and analysis on air-to-air and air-to-water heat pump heating systems
    Xiao, Biao
    He, Lin
    Zhang, Shihang
    Kong, Tingting
    Hu, Bin
    Wang, R. Z.
    RENEWABLE ENERGY, 2020, 146 : 1888 - 1896
  • [50] Investigation of thermal performance of an air-to-air thermosyphon heat exchanger using ε-NTU method
    Noie, SH
    APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) : 559 - 567