Estimation of Blood Pressure by Using Electrocardiogram(ECG) and Photo-plethysmogram(PPG)

被引:12
|
作者
Kumar, Sarvesh [1 ]
Ayub, Shahanaz [1 ]
机构
[1] Bundelkhand Inst Engn & TechnologyJhansi, Dept Elect & Commun Engn, Jhansi 284128, Uttar Pradesh, India
关键词
ECG; PPG; Blood Pressure; Pulse Transit time (PTT); PULSE;
D O I
10.1109/CSNT.2015.99
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the current study, we found the relationship between blood pressure (BP) and pulse transit time (PTT). After measuring ECG and photoplethysmogram, the PTT was calculated from the acquired signals. Blood pressure (BP), the pressure exerted by circulating blood upon the walls of blood vessels, is an important physiological parameter and can provide some information forpersonal healthcare. Pulse transit time is the time taken for the arterial pulse Pressure wave to travel from the aortic valve to a peripheral site. It is usually measured from the R wave on the electrocardiogram to a photoplethysmography signal. PTT is inversely proportional to blood pressure. The mean error are 0.29 mmHg for SBP and 0.1mmHg for DBP. These results are satisfied with the regulation of ANSI/AAMI for certification of sphygmomanometer that real measurement error valueshould be within the mean error of +/- 5mmHg.
引用
收藏
页码:521 / 524
页数:4
相关论文
共 50 条
  • [31] Continuous Blood Pressure Prediction from Pulse Transit Time Using ECG and PPG Signals
    Ghosh, Shrimanti
    Banerjee, Ankur
    Ray, Nilanjan
    Wood, Peter W.
    Boulanger, Pierre
    Padwal, Raj
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 188 - 191
  • [32] Continuous Peripheral Blood Pressure Measurement with ECG and PPG Signals at Fingertips
    Lee, Kar Mun
    Qian, Zhengyang
    Yabuki, Ryosuke
    Du, Bang
    Kino, Hisashi
    Fukushima, Takafumi
    Kiyoyama, Koji
    Tanaka, Tetsu
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 471 - 474
  • [33] The influence of physiological characteristics on blood pressure estimation using only PPG signals
    Sen, Yang
    Morgan, Stephen P.
    Cho, Siu-Yeung
    Zhang Yaping
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 1694 - 1700
  • [34] Continuous Blood Pressure Estimation from PPG Signal
    Slapnicar, Gasper
    Lustrek, Mitja
    Marinko, Matej
    INFORMATICA-JOURNAL OF COMPUTING AND INFORMATICS, 2018, 42 (01): : 33 - 42
  • [35] Continuous blood pressure estimation from PPG signal
    2018, Slovene Society Informatika (42):
  • [36] Electrocardiogram-Assisted Blood Pressure Estimation
    Ahmad, Saif
    Chen, Silu
    Soueidan, Karen
    Batkin, Izmail
    Bolic, Miodrag
    Dajani, Hilmi
    Groza, Voicu
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (03) : 608 - 618
  • [37] Estimation of Beat-by-Beat Blood Pressure and Heart Rate From ECG and PPG Using a Fine-Tuned Deep CNN Model
    Yen, Chih-Ta
    Chang, Sheng-Nan
    Liao, Cheng-Hong
    IEEE ACCESS, 2022, 10 : 85459 - 85469
  • [38] Improved PPG-based estimation of the blood pressure using latent space features
    Hassani, Atefe
    Foruzan, Amir Hossein
    SIGNAL IMAGE AND VIDEO PROCESSING, 2019, 13 (06) : 1141 - 1147
  • [39] Improved PPG-based estimation of the blood pressure using latent space features
    Atefe Hassani
    Amir Hossein Foruzan
    Signal, Image and Video Processing, 2019, 13 : 1141 - 1147
  • [40] ECG-AI FOR BLOOD PRESSURE ESTIMATION
    Karabayir, Ibrahim
    Davis, Robert
    Chinthala, Lokesh
    Butler, Liam
    Celik, Turgay
    Kilic, Ugur
    Akbilgic, Oguz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 2646 - 2646