Restoring euglycemia in the basal state using continuous glucose monitoring in subjects with type 1 diabetes mellitus

被引:6
|
作者
Zisser, Howard C. [1 ]
Bevier, Wendy C. [1 ]
Jovanovic, Lois [1 ]
机构
[1] Sansum Diabet Res Inst, Santa Barbara, CA 93105 USA
关键词
GLYCEMIC CONTROL; THERAPY; SYSTEM; SENSOR; TRIAL; CGMS;
D O I
10.1089/dia.2007.0220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Our objective was to use continuous glucose monitoring to derive the optimal basal insulin infusion rates in adults with type I diabetes and using continuous subcutaneous insulin infusion (CSII) pumps. Methods: In an effort to mimic euglycemia during the basal state, we used a standard protocol to adjust basal insulin infusion rates in 16 subjects with type 1 diabetes mellitus who were using CSII pumps. All subjects wore Continuous Glucose Monitoring System sensors (CGMS((R)), Medtronic Minimed, Northridge, CA) in order to obtain around-the-clock tracings of their glucose measurements. Subjects were asked to skip meals periodically in order to optimize basal insulin infusion rates, defined as the basal infusion rates that maintained glucose levels in the range of 65-120 mg/dL during the fasting state or between meals. Results: In order to demonstrate improved glycemic control, with blunting of glucose excursion, we compared the baseline CGMS area under the curve (AUC) to the AUC obtained after optimizing the basal insulin dosages. We analyzed the curves by determining the AUC for glucose excursions above 110 mg/dL. The AUC for glucose excursions above 110 mg/dL was significantly smaller after optimization (19 +/- 13 mg/dLday) compared to the baseline AUC (50 31 mg/dL-day) (P < 0.001). Conclusions: Using both a standard protocol for initial basal insulin infusion rates and CGMS curves to optimize basal infusion rates, one can improve glycemia in subjects with type 1 diabetes using CSII.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [21] Continuous Glucose Monitoring in Type 1 Diabetes Mellitus during High Altitude Mountaineering
    Mol, Pieter D. E.
    Vries, Suzanna D. E.
    Koning, Eelco D. E.
    Fokkert, Marion
    Dikkeschei, Bert
    Bilo, Henk
    DIABETES, 2009, 58 : A107 - A107
  • [22] Polysomnography and continuous glucose monitoring in children and adolescents with type 1 diabetes mellitus.
    Castronovo, VE
    Salvatoni, A
    Nosetti, L
    Marazzini, C
    Zucconi, M
    Nespoli, L
    Ferini-Strambi, L
    SLEEP, 2002, 25 : A155 - A155
  • [23] How effective is continuous glucose monitoring in intensively treated type 1 diabetes mellitus?
    Wolfsdorf, Joseph I.
    NATURE CLINICAL PRACTICE ENDOCRINOLOGY & METABOLISM, 2009, 5 (03): : 134 - 135
  • [24] Insulin Pumps and Continuous Glucose Monitoring in Pediatric Patients With Type 1 Diabetes Mellitus
    Tamborlane, William V.
    ENDOCRINE PRACTICE, 2012, 18 : 13 - 16
  • [25] Parental Experiences of Continuous Glucose Monitoring in Danish Children with Type 1 Diabetes Mellitus
    Haslund-Thomsen, Helle
    Hasselbalch, Line Aagaard
    Laugesen, Britt
    JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2020, 53 : E149 - E155
  • [26] The Benefits of Using Continuous Glucose Monitoring to Diagnose Type 1 Diabetes
    Ayers, Alessandra T.
    Ho, Cindy N.
    Wong, Jenise C.
    Kerr, David
    Mader, Julia K.
    Klonoff, David C.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [27] Continuous glucose monitoring for the routine care of type 2 diabetes mellitus
    Ajjan, Ramzi
    Battelino, Tadej
    Cos, Xavier
    Del Prato, Stefano
    Philips, Jean-Christophe
    Meyer, Laurent
    Seufert, Jochen
    Seidu, Samuel
    NATURE REVIEWS ENDOCRINOLOGY, 2024, 20 (07) : 426 - 440
  • [28] Impact of the basal/bolus ratio on continuous glucose monitoring parameters in patients with type 1 diabetes
    Gonzalez-Vidal, Tomas
    Rivas-Otero, Diego
    Ramos-Ruiz, Guillermo
    Agueeria-Cabal, Pablo
    Lambert, Carmen
    Ares, Jessica
    Delgado, Elias
    Menendez-Torre, Edelmiro
    DIABETES OBESITY & METABOLISM, 2024, 26 (08): : 3482 - 3485
  • [29] Responses to Continuous Glucose Monitoring in Subjects with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections
    Rodbard, David
    Jovanovic, Lois
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (12) : 757 - 765
  • [30] Effects of Basal Doses of Insulin Treatment in Type 1 Diabetes Evaluated by Continuous Glucose Monitoring on Glucose Variability
    Proietti, Adrian E., Sr.
    Daghero, Andrea V., Sr.
    Panei, Nicolas, Sr.
    Scapuzzi, Maria L., Sr.
    Jokiel, Andrea E., Sr.
    Glesias, Maria Laura, Sr.
    Velazquez, Julieta
    Nogueira, Juan P., Sr.
    DIABETES, 2018, 67