Restoring euglycemia in the basal state using continuous glucose monitoring in subjects with type 1 diabetes mellitus

被引:6
|
作者
Zisser, Howard C. [1 ]
Bevier, Wendy C. [1 ]
Jovanovic, Lois [1 ]
机构
[1] Sansum Diabet Res Inst, Santa Barbara, CA 93105 USA
关键词
GLYCEMIC CONTROL; THERAPY; SYSTEM; SENSOR; TRIAL; CGMS;
D O I
10.1089/dia.2007.0220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Our objective was to use continuous glucose monitoring to derive the optimal basal insulin infusion rates in adults with type I diabetes and using continuous subcutaneous insulin infusion (CSII) pumps. Methods: In an effort to mimic euglycemia during the basal state, we used a standard protocol to adjust basal insulin infusion rates in 16 subjects with type 1 diabetes mellitus who were using CSII pumps. All subjects wore Continuous Glucose Monitoring System sensors (CGMS((R)), Medtronic Minimed, Northridge, CA) in order to obtain around-the-clock tracings of their glucose measurements. Subjects were asked to skip meals periodically in order to optimize basal insulin infusion rates, defined as the basal infusion rates that maintained glucose levels in the range of 65-120 mg/dL during the fasting state or between meals. Results: In order to demonstrate improved glycemic control, with blunting of glucose excursion, we compared the baseline CGMS area under the curve (AUC) to the AUC obtained after optimizing the basal insulin dosages. We analyzed the curves by determining the AUC for glucose excursions above 110 mg/dL. The AUC for glucose excursions above 110 mg/dL was significantly smaller after optimization (19 +/- 13 mg/dLday) compared to the baseline AUC (50 31 mg/dL-day) (P < 0.001). Conclusions: Using both a standard protocol for initial basal insulin infusion rates and CGMS curves to optimize basal infusion rates, one can improve glycemia in subjects with type 1 diabetes using CSII.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [1] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    DIABETOLOGE, 2019, 15 (08): : 744 - 746
  • [2] Continuous glucose monitoring in type 1 diabetes mellitus
    Tamborlane, William V.
    Beck, Roy W.
    LANCET, 2009, 373 (9677): : 1744 - 1746
  • [3] Continuous glucose monitoring systems for type 1 diabetes mellitus
    Langendam, Miranda W.
    Luijf, Yoeri M.
    Hooft, Lotty
    DeVries, J. Hans
    Mudde, Aart H.
    Scholten, Rob J. P. M.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (01):
  • [4] Professional Continuous Glucose Monitoring for the Identification of Type 1 Diabetes Mellitus Among Subjects With Insulin Therapy
    Chen, Yin-Chun
    Huang, Yu-Yao
    Li, Hung-Yuan
    Liu, Shih-Wei
    Hsieh, Sheng-Hwu
    Lin, Chia-Hung
    MEDICINE, 2015, 94 (03) : e421
  • [5] Continuous Glucose Monitoring in Pregnancies Complicated by Type 1 Diabetes Mellitus
    Herrero, Tiffany
    Coleman, Todd
    Laurent, Louise
    Moore, Thomas
    Ramos, Gladys
    OBSTETRICS AND GYNECOLOGY, 2018, 131 : 125S - 125S
  • [6] Continuous Glucose Monitoring Improves Glycemic Control in Subjects With Type 2 Diabetes on Basal Insulin
    Manning, James P.
    Halford, Jean R.
    Liljenquist, David R.
    Sulik, Mark B.
    Sulik, Rebecca T.
    DIABETES, 2012, 61 : A587 - A587
  • [7] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Vokounova-Honsova, Sarka
    Navratil, Tomas
    Kohlikova, Eva
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1659 - 1669
  • [8] Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
    Lin, Rose
    Brown, Fran
    James, Steven
    Jones, Jessica
    Ekinci, Elif
    DIABETIC MEDICINE, 2021, 38 (05)
  • [9] Continuous glucose monitoring for the evaluation of gravid women with Type 1 diabetes mellitus
    Yogev, Y
    Chen, R
    Ben-Haroush, A
    Peled, Y
    Jovanovic, L
    Phillip, M
    Hod, M
    DIABETOLOGIA, 2002, 45 : A296 - A296
  • [10] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Šárka Vokounová-Honsová
    Tomáš Navrátil
    Eva Kohlíková
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1659 - 1669