A PDA-based research platform for cochlear implants

被引:12
|
作者
Lobo, Arthur P. [1 ]
Loizou, Philip C. [1 ]
Kehtarnavaz, Nasser [1 ]
Torlak, Murat [1 ]
Lee, Hoi [1 ]
Sharma, Anu [2 ]
Gilley, Phillip [2 ]
Peddigari, Venkat [1 ]
Ramanna, Lakshmish [1 ]
机构
[1] Univ Texas, Dept Elect Engn, Richardson, TX 75080 USA
[2] Univ Colorado, Dept Speech Language & Hearing Sci, Boulder, CO 80309 USA
关键词
D O I
10.1109/CNE.2007.369603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently researchers interested in developing new signal processing algorithms for commercially available cochlear implants must rely on coding these algorithms in low-level assembly language. We propose a Personal Digital Assistant (PDA) based research platform for developing and testing in real-time new signal processing strategies for cochlear implants. Software development can be done either in C or in LabVIEW. The C implementation can be further optimized using Intel's primitive routines. In this paper, we report on the real-time implementation of a 16-channel noise-band vocoder algorithm, which is a similar algorithm used in commercially available implant processors. We further report on EEG recordings on the PDA acquired through a compact-flash data acquisition card.
引用
收藏
页码:28 / +
页数:2
相关论文
共 50 条
  • [31] Wireless PDA-based electrocardiogram transmission system for telemedicine
    Zhu Qiang
    Wang Mingshi
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3807 - 3809
  • [32] Feasibility of direct patient use of PDA-based surveys
    Afrin, LB
    Hannah, S
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2001, : 846 - 846
  • [33] A PDA-based electrcardiogram/blood pressure telemonitor for telemedicine
    Bolaños, M
    Nazeran, H
    Gonzalez, I
    Parra, R
    Martinez, C
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2169 - 2172
  • [34] Research in and implementation of mobile agent platform based on pda
    Cao, Xiedong
    Li, Yang
    Jie, Li
    Wei, Fang
    Xin, Ying
    2007 International Symposium on Computer Science & Technology, Proceedings, 2007, : 1136 - 1138
  • [35] PDA-Based research in Design and development of pretreatment operation system on field data collection results
    Wang Li
    He Dongcai
    FIFTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2013), 2013, 8878
  • [36] A PDA-Based Modular and Multipurpose System for Intelligent Ubiquitous Monitoring
    Presedo, J.
    Tarasco, M.
    Teijeiro, T.
    Castro, D.
    Felix, P.
    WISP 2009: 6TH IEEE INTERNATIONAL SYMPOSIUM ON INTELLIGENT SIGNAL PROCESSING, PROCEEDINGS, 2009, : 223 - 228
  • [37] A PDA-based wireless liosensor using industry standard components
    Sommers, DR
    Stubbs, DD
    Hunt, WD
    IEEE SENSORS JOURNAL, 2004, 4 (05) : 551 - 558
  • [38] Design of a PDA-based Asthma Peak Flow Monitor System
    Wu, C. -M.
    Su, C. -W.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 501 - 504
  • [39] A PDA-based ECG beat detector for home cardiac care
    Goh, K. W.
    Lavanya, J.
    Kim, Y.
    Tan, E. K.
    Soh, C. B.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 375 - 378
  • [40] PDA-based Boolean function simplification: a useful educational tool
    Bitincka, L
    Antoniou, GE
    INFORMATICA, 2004, 15 (03) : 329 - 336