Measurement of Resistive Plantar Flexion Torque of the Ankle during Passive Stretch in Healthy Subjects and Patients with Poststroke Hemiplegia

被引:4
|
作者
Mizuno, Shiho [1 ]
Sonoda, Shigeru [1 ]
Takeda, Kotaro [2 ]
Maeshima, Shinichiro [1 ]
机构
[1] Fujita Hlth Univ, Dept Rehabil Med 2, Sch Med, 424-1 Ohtori Cho, Tsu, Mie 5141295, Japan
[2] Fujita Hlth Univ, Fujita Mem Nanakuri Inst, Tsu, Mie, Japan
来源
关键词
Quantitative evaluation; increased muscle tone; stroke; spasticity; MODIFIED ASHWORTH SCALE; MODIFIED TARDIEU SCALE; SPINAL-CORD-INJURY; INTERRATER RELIABILITY; BRAIN-INJURY; CHRONIC HEMIPARESIS; STIFFNESS; SPASTICITY; STROKE; RESISTANCE;
D O I
10.1016/j.jstrokecerebrovasdis.2015.12.036
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Quantification of increased muscle tone for patients with spasticity has been performed to date using various devices to replace the manual scales, such as the modified Ashworth scale or the Tardieu scale. We developed a device that could measure resistive plantar flexion (PF) torque of the ankle during passive dorsiflexion (DF) as an indicator of muscle tone of ankle plantar flexors. Methods: The primary objective was to explore the test-retest intrarater reliability of a custom-built device. Participants were 11 healthy subjects (7 men, 4 women; mean age 47.0 years) and 22 patients with poststroke hemiplegia (11 hemorrhagic, 11 ischemic; 14 men, 8 women; mean age 57.2 years). The device was affixed to the ankle. Subjects were seated with knees either flexed or extended. The ankle was passively dorsiflexed from 20 degrees of PF to more than 10 degrees of DF at 5 degrees/second (slow stretch) or 90 degrees/second (fast stretch). Angle and torque were measured twice during the stretches. The intraclass correlation coefficients (ICCs) of torque at 10 degrees of DF (T10) in the 4 conditions-slow and fast stretches with knee flexed or extended-were calculated. Results: The T10 ICCs of the 4 conditions were .95-.99 in both groups. The healthy subjects showed significantly higher T10 of knee extension than of knee flexion during slow and fast stretches. The patients showed increased velocity-dependent torque during fast stretches. Conclusions: Excellent reliability was observed. The device is suitable for measuring resistive PF torque during passive stretch in a flexed knee condition.
引用
收藏
页码:946 / 953
页数:8
相关论文
共 37 条
  • [21] Assessment of lower leg muscle force distribution during isometric ankle dorsi and plantar flexion in patients with diabetes: a preliminary study
    Blazkiewicz, Michalina
    Sundar, Lakshmi
    Healy, Aoife
    Ramachandran, Ambady
    Chockalingam, Nachiappan
    Naemi, Roozbeh
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2015, 29 (02) : 282 - 287
  • [22] Effect of a rigid ankle foot orthosis and an ankle foot orthosis with an oil damper plantar flexion resistance on pelvic and thoracic movements of patients with stroke during gait
    Ling, Hua
    Guo, Hui
    Zhou, Hao
    Chang, Xiao-Qian
    Guo, Zi-Yang
    Yamamoto, Sumiko
    Cai, Li-Fei
    Zhao, Jun
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [23] Effect of a rigid ankle foot orthosis and an ankle foot orthosis with an oil damper plantar flexion resistance on pelvic and thoracic movements of patients with stroke during gait
    Hua Ling
    Hui Guo
    Hao Zhou
    Xiao-Qian Chang
    Zi-Yang Guo
    Sumiko Yamamoto
    Li-Fei Cai
    Jun Zhao
    BioMedical Engineering OnLine, 22
  • [24] Relationship of EMG/SMG features and muscle strength level: an exploratory study on tibialis anterior muscles during plantar-flexion among hemiplegia patients
    Li, Huihui
    Zhao, Guoru
    Zhou, Yongjin
    Chen, Xin
    Ji, Zhen
    Wang, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [25] Relationship of EMG/SMG features and muscle strength level: an exploratory study on tibialis anterior muscles during plantar-flexion among hemiplegia patients
    Huihui Li
    Guoru Zhao
    Yongjin Zhou
    Xin Chen
    Zhen Ji
    Lei Wang
    BioMedical Engineering OnLine, 13
  • [26] Evaluation of a novel elbow joint torque measurement device in healthy subjects and stroke patients: a randomized trial
    Qingqin Xu
    Mengxuan Hu
    Lei Li
    Shi Chen
    Bo Liu
    Jianwei Lu
    Hemu Chen
    Scientific Reports, 15 (1)
  • [27] Reliability of stiffness measurement device during passive isokinetic spastic wrist movements of healthy subjects and hemiplegics
    Orand, Abbas
    Miyasaka, Hiroyuki
    Takeda, Kotaro
    Tanino, Genichi
    Chihara, Takeshi
    Beppu, Hidehiko
    Sonoda, Shigeru
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2017, 37 (01) : 114 - 123
  • [28] Input-output properties of the soleus stretch reflex in spastic stroke patients and healthy subjects during walking
    Nielsen, JF
    Andersen, JB
    Barbeau, H
    Sinkjaer, T
    NEUROREHABILITATION, 1998, 10 (02) : 151 - 166
  • [29] Ankle-foot orthosis with dorsiflexion resistance using spring-cam mechanism increases knee flexion in the swing phase during walking in stroke patients with hemiplegia
    Sekiguchi, Yusuke
    Owaki, Dai
    Honda, Keita
    Fukushi, Kenichiro
    Hiroi, Noriyoshi
    Nozaki, Takeo
    Izumi, Shin-ichi
    GAIT & POSTURE, 2020, 81 : 27 - 32
  • [30] A comparison of eccentric isokinetic torque production and velocity of knee flexion angle during step down in patellofemoral pain syndrome patients and unaffected subjects
    Anderson, G
    Herrington, L
    CLINICAL BIOMECHANICS, 2003, 18 (06) : 500 - 504