Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography

被引:53
|
作者
Dalbert, Adrian [1 ]
Huber, Alexander
Veraguth, Dorothe
Roosli, Christof
Pfiffner, Flurin
机构
[1] Univ Zurich Hosp, Dept Otorhinolaryngol Head & Neck Surg, Frauenklinikstr 24, CH-8091 Zurich, Switzerland
关键词
Cochlear implant; Cochlear implantation; Electrocochleography; Hearing preservation; Residual hearing; ROUND WINDOW ELECTROCOCHLEOGRAPHY; HUMAN TEMPORAL BONES; HEARING PRESERVATION; ELECTRODE ARRAY; INTRACOCHLEAR ELECTROCOCHLEOGRAPHY; RESIDUAL HEARING; ELECTROPHYSIOLOGICAL PROPERTIES; DAMAGE; POSITION; OUTCOMES;
D O I
10.1097/MAO.0000000000000998
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To assess cochlear trauma during cochlear implantation by electrocochleography (ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative cochlear trauma with postoperative loss of residual hearing. Methods: ECoG recordings to tone bursts at 250, 500, 750, and 1000 Hz and click stimuli were recorded before and after insertion of the cochlear implant electrode array, using an extracochlear recording electrode. CBCTs were conducted within 6 weeks after surgery. Changes of intraoperative ECoG recordings and CBCT findings were correlated with postoperative threshold shifts in pure-tone audiograms. Results: Fourteen subjects were included. In three subjects a decrease of low-frequency ECoG responses at 250, 500, 750, and 1000 Hz occurred after insertion of the electrode array. This was associated with no or minimal residual hearing 4 weeks after surgery. ECoG responses to click stimuli were present in six subjects and showed a decrease after insertion of the electrode array in three. This was associated with a mean hearing loss of 21 dB in postoperative pure-tone audiograms. Scalar dislocation of the electrode array was assumed in one subject because of CBCT findings and correlated with a decrease of low-frequency ECoG responses and a complete loss of residual hearing. Conclusion: Hearing loss of <= 11 dB is not associated with detectable decrease in ECoG recordings during cochlear implantation. However, in a majority of patients with threshold shifts of >11 dB or complete hearing loss, an intraoperative decrease of high-or low-frequency ECoG signals occurs, suggesting acute cochlear trauma.
引用
收藏
页码:446 / 453
页数:8
相关论文
共 50 条
  • [31] Automatic analysis of cochlear response using electrocochleography signals during cochlear implant surgery
    Wijewickrema, Sudanthi
    Bester, Christofer
    Gerard, Jean-Marc
    Collins, Aaron
    O'Leary, Stephen
    PLOS ONE, 2022, 17 (07):
  • [32] Cochlear implants: Insertion assessment by computed tomography
    Menegatti Pavan, Ana Luiza
    Fattori Alves, Allan Felipe
    Giacomini, Guilherme
    Carrasco Altemani, Joao Mauricio
    Castilho, Arthur Menino
    Lauria, Raquel Andrade
    Rodrigues da Silva, Vagner Antonio
    Guimaraes, Alexandre Caixeta
    de Pina, Diana Rodrigues
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2018, 39 (04) : 431 - 435
  • [33] Classification of Acoustic Hearing Preservation After Cochlear Implantation Using Electrocochleography
    Sijgers, Leanne
    Sorensen, Torquil
    Soulby, Andrew
    Boyle, Patrick
    Dalbert, Adrian
    Roeoesli, Christof
    Jablonski, Greg Eigner
    Hamacher, Volkmar
    Greisiger, Ralf
    Jiang, Dan
    Huber, Alexander
    Pfiffner, Flurin
    TRENDS IN HEARING, 2023, 27
  • [34] Objective evaluation, using computed tomography, of round window access for cochlear implantation
    Radomska, Katarzyna
    Mielnik, Michal
    Gostynski, Marcin
    Dzieciolowska-Baran, Edyta
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (12) : 6367 - 6376
  • [35] Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
    Alahmadi, Asma
    Hamed, Nezar
    Abdelsamad, Yassin
    Sharif, Tahir
    Alshalan, Afrah
    Alzhrani, Farid
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2025, (215):
  • [36] Computed Tomography Estimation of Cochlear Duct Length Can Predict Full Insertion in Cochlear Implantation
    Johnston, James D. A.
    Scoffings, Daniel
    Chung, Mark
    Baguley, David
    Donnelly, Neil P.
    Axon, Patrick R.
    Gray, Roger F.
    Tysome, James R.
    OTOLOGY & NEUROTOLOGY, 2016, 37 (03) : 223 - 228
  • [37] Electrocochleography in cochlear implantation: Development, applications, and future directions
    Barnes, Jason H.
    Yin, Linda X.
    Saoji, Aniket A.
    Carlson, Matthew L.
    WORLD JOURNAL OF OTORHINOLARYNGOLOGY-HEAD & NECK SURGERY, 2021, 7 (02): : 94 - 100
  • [38] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [39] Accuracy of high-resolution computed tomography in cochlear implantation
    Langman, AW
    Quigley, SM
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1996, 114 (01) : 38 - 43
  • [40] Is Characteristic Frequency Limiting Real-Time Electrocochleography During Cochlear Implantation?
    Walia, Amit
    Shew, Matthew A.
    Lefler, Shannon M.
    Kallogjeri, Dorina
    Wick, Cameron C.
    Holden, Timothy A.
    Durakovic, Nedim
    Ortmann, Amanda J.
    Herzog, Jacques A.
    Buchman, Craig A.
    FRONTIERS IN NEUROSCIENCE, 2022, 16