Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography

被引:53
|
作者
Dalbert, Adrian [1 ]
Huber, Alexander
Veraguth, Dorothe
Roosli, Christof
Pfiffner, Flurin
机构
[1] Univ Zurich Hosp, Dept Otorhinolaryngol Head & Neck Surg, Frauenklinikstr 24, CH-8091 Zurich, Switzerland
关键词
Cochlear implant; Cochlear implantation; Electrocochleography; Hearing preservation; Residual hearing; ROUND WINDOW ELECTROCOCHLEOGRAPHY; HUMAN TEMPORAL BONES; HEARING PRESERVATION; ELECTRODE ARRAY; INTRACOCHLEAR ELECTROCOCHLEOGRAPHY; RESIDUAL HEARING; ELECTROPHYSIOLOGICAL PROPERTIES; DAMAGE; POSITION; OUTCOMES;
D O I
10.1097/MAO.0000000000000998
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To assess cochlear trauma during cochlear implantation by electrocochleography (ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative cochlear trauma with postoperative loss of residual hearing. Methods: ECoG recordings to tone bursts at 250, 500, 750, and 1000 Hz and click stimuli were recorded before and after insertion of the cochlear implant electrode array, using an extracochlear recording electrode. CBCTs were conducted within 6 weeks after surgery. Changes of intraoperative ECoG recordings and CBCT findings were correlated with postoperative threshold shifts in pure-tone audiograms. Results: Fourteen subjects were included. In three subjects a decrease of low-frequency ECoG responses at 250, 500, 750, and 1000 Hz occurred after insertion of the electrode array. This was associated with no or minimal residual hearing 4 weeks after surgery. ECoG responses to click stimuli were present in six subjects and showed a decrease after insertion of the electrode array in three. This was associated with a mean hearing loss of 21 dB in postoperative pure-tone audiograms. Scalar dislocation of the electrode array was assumed in one subject because of CBCT findings and correlated with a decrease of low-frequency ECoG responses and a complete loss of residual hearing. Conclusion: Hearing loss of <= 11 dB is not associated with detectable decrease in ECoG recordings during cochlear implantation. However, in a majority of patients with threshold shifts of >11 dB or complete hearing loss, an intraoperative decrease of high-or low-frequency ECoG signals occurs, suggesting acute cochlear trauma.
引用
收藏
页码:446 / 453
页数:8
相关论文
共 50 条
  • [1] Assessing Cochlear Length Using Cone Beam Computed Tomography in Adults With Cochlear Implants
    Alnafjan, Fadwa F.
    Allan, Stuart M.
    McMahon, Catherine M.
    da Cruz, Melville J.
    OTOLOGY & NEUROTOLOGY, 2018, 39 (09) : E757 - E764
  • [2] Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography
    Dalbert, Adrian
    Pfiffner, Flurin
    Hoesli, Marco
    Koka, Kanthaiah
    Veraguth, Dorothe
    Roosli, Christof
    Huber, Alexander
    FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [3] Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear Implantation
    Ruivo, Joana
    Mermuys, Koen
    Bacher, Klaus
    Kuhweide, Rudolf
    Offeciers, Erwin
    Casselman, Jan W.
    OTOLOGY & NEUROTOLOGY, 2009, 30 (03) : 299 - 303
  • [4] Intracochlear Electrocochleography During Cochlear Implantation
    Calloway, Nathan H.
    Fitzpatrick, Douglas C.
    Campbell, Adam P.
    Iseli, Claire
    Pulver, Stephen
    Buchman, Craig A.
    Adunka, Oliver F.
    OTOLOGY & NEUROTOLOGY, 2014, 35 (08) : 1451 - 1457
  • [5] Electrocochleography during Cochlear Implantation for Hearing Preservation
    Mandala, Marco
    Colletti, Liliana
    Tonoli, Giovanni
    Colletti, Vittorio
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2012, 146 (05) : 774 - 781
  • [6] Performing Intracochlear Electrocochleography during Cochlear Implantation
    Schuerch, Klaus
    Waser, Manuel
    Mantokoudis, Georgios
    Anschuetz, Lukas
    Wimmer, Wilhelm
    Caversaccio, Marco
    Weder, Stefan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (181):
  • [7] Cochlear length determination using Cone Beam Computed Tomography in a clinical setting
    Wuerfel, Waldemar
    Lanfermann, Heinrich
    Lenarz, Thomas
    Majdani, Omid
    HEARING RESEARCH, 2014, 316 : 65 - 72
  • [8] Establishing Reproducibility and Correlation of Cochlear Microphonic Amplitude to Implant Electrode Position Using Intraoperative Electrocochleography and Postoperative Cone Beam Computed Tomography
    Soulby, Andrew
    Connor, Steve
    Jiang, Dan
    Nunn, Terry
    Boyle, Patrick
    Pai, Irumee
    EAR AND HEARING, 2021, 42 (05): : 1263 - 1275
  • [9] Imaging of the human cochlea using micro-computed tomography before and after cochlear implantation: comparison with cone-beam computed tomography
    Karkas, Alexandre
    Boureille, Pierre
    Laroche, Norbert
    Vico, Laurence
    Bergandi, Florian
    Marotte, Hubert
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (07) : 3131 - 3140
  • [10] Imaging of the human cochlea using micro-computed tomography before and after cochlear implantation: comparison with cone-beam computed tomography
    Alexandre Karkas
    Pierre Boureille
    Norbert Laroche
    Laurence Vico
    Florian Bergandi
    Hubert Marotte
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 3131 - 3140