A Simple Monitor for Tracking NBTI in Integrated Systems

被引:2
|
作者
Strong, Matthew [1 ]
Bhatheja, Kushagra [1 ]
Yang, Ruohan [1 ]
Chen, Degang [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
关键词
reliability; ageing; NBTI; on-chip monitor; NBTI monitor;
D O I
10.1109/MWSCAS47672.2021.9531715
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
NBTI is one of the primary concerns for long-term reliability in systems using deep submicron technologies. In this paper, we propose a simple on-chip sensor architecture that monitors degradation due to NBTI through pseudo-static measurements of the relative shift in threshold voltage. A representative pMOSFET is stressed to intentionally induce NBTI and then compared to a reference pMOSFET that is ideally unaffected by ageing. The proposed architecture can be used to measure degradation in multiple devices that are stressed under a variety of conditions with minimal additional overhead. The use of pseudo-static measurements reduces the measurement error introduced by the ageing of devices in supporting circuitry, and it allows for measurements to be completed in relatively few clock cycles.
引用
收藏
页码:1112 / 1115
页数:4
相关论文
共 50 条
  • [1] A simple tracking system to monitor solar PV panels
    Bentaher, H.
    Kaich, H.
    Ayadi, N.
    Ben Hmouda, M.
    Maalej, A.
    Lemmer, U.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 872 - 875
  • [2] On-Chip NBTI and PBTI Tracking through an All-Digital Aging Monitor Architecture
    Alidash, Hossein Karimiyan
    Calimera, Andrea
    Macii, Alberto
    Macii, Enrico
    Poncino, Massimo
    INTEGRATED CIRCUIT AND SYSTEM DESIGN: POWER AND TIMING MODELING, OPTIMIZATION AND SIMULATION, 2013, 7606 : 155 - 165
  • [3] SIMPLE PRESSURE MONITOR FOR CPAP SYSTEMS
    DAMIA, G
    PELIZZOLA, A
    BETTALE, L
    SOLCA, M
    ACUTE CARE, 1985, 11 (3-4) : 205 - 207
  • [4] Waveform tracking monitor for power distribution systems
    Gou, B
    Luo, C
    Ponci, F
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 2341 - 2345
  • [5] A novel waveform tracking monitor for power systems
    Gou, Bei
    Luo, Cheng
    Ponci, Ferdinanda
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (04) : 1874 - 1882
  • [6] A simple integrated ratiometric wavelength monitor based on a directional coupler
    Hatta, A. M.
    Farrell, G.
    Semenova, Y.
    Wang, Q.
    OPTIK, 2014, 125 (02): : 795 - 798
  • [7] ERROR MONITOR FOR PHOTO-ELECTRIC TRACKING SYSTEMS
    GULGAZARYAN, KA
    SARKISYAN, ST
    MEASUREMENT TECHNIQUES, 1978, 21 (08) : 1105 - 1107
  • [8] An On-Chip Sensor to Monitor NBTI Effects in SRAMs
    Ceratti, A.
    Copetti, T.
    Bolzani, L.
    Vargas, F.
    Fagundes, R.
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2014, 30 (02): : 159 - 169
  • [9] An On-Chip Sensor to Monitor NBTI Effects in SRAMs
    A. Ceratti
    T. Copetti
    L. Bolzani
    F. Vargas
    R. Fagundes
    Journal of Electronic Testing, 2014, 30 : 159 - 169
  • [10] A simple integrated ratiometric wavelength monitor based on multimode interference structure
    Hatta, Agus Muhamad
    Farrell, Gerald
    Wang, Qian
    OPTICAL DESIGN AND ENGINEERING III, PTS 1 AND 2, 2008, 7100