An observational study of the Baska® mask: a novel supraglottic airway

被引:50
|
作者
Alexiev, V. [1 ,2 ,3 ]
Salim, A. [1 ,2 ,3 ]
Kevin, L. G. [1 ,2 ,3 ]
Laffey, J. G. [1 ,2 ,3 ]
机构
[1] Galway Univ Hosp, Dept Anaesthesia & Intens Care Med, Galway, Ireland
[2] Natl Univ Ireland, Sch Med, Inst Clin Sci, Galway, Ireland
[3] Natl Univ Ireland, Galway HRB Clin Res Facil, Galway, Ireland
关键词
CERVICAL-SPINE IMMOBILIZATION; TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPES; I-GEL; NOVICE PERSONNEL; AIRTRAQ(R); AIRWAYSCOPE(R); TRIAL; ADEPT;
D O I
10.1111/j.1365-2044.2012.07140.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Baska mask is a novel supraglottic airway device. We conducted an initial observational study to assess this device in 30 low-risk female patients. All Baska masks were inserted by a single investigator. The overall success rate for device insertion was 96.7% (95% CI 82.899.9%), while the success rate for the first insertion attempt was 76.7% (95% CI 57.790.1%). The device was easy to insert, with a mean (SD) difficulty score of 0.9 (1.6) on a 10-cm scale. The mean (SD) airway leak pressure was 35.7 (13.3) cmH2O. The incidence of throat pain, dysphonia and dysphagia was low. We conclude that the Baska mask demonstrates a level of utility as an alternative supraglottic airway that is worthy of further clinical study.
引用
收藏
页码:640 / 645
页数:6
相关论文
共 50 条
  • [31] Does Baska mask deserve its own niche among extraglottic airway devices? A prospective, single-arm study
    Shah, Vinisha
    Sharma, Kailash S.
    Kulkarni, Atul P.
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (07) : 603 - 608
  • [32] Comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway
    Xue, F. S.
    Wang, Q.
    Yuan, Y. J.
    Xiong, J.
    Liao, X.
    RESUSCITATION, 2010, 81 (07) : 910 - 911
  • [33] A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway
    Janakiraman, C.
    Chethan, D. B.
    Wilkes, A. R.
    Stacey, M. R.
    Goodwin, N.
    ANAESTHESIA, 2009, 64 (06) : 674 - 678
  • [34] Comparison of the Baska® mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery
    Alexiev, V.
    Ochana, A.
    Abdelrahman, D.
    Coyne, J.
    McDonnell, J. G.
    O'Toole, D. P.
    Neligan, P.
    Laffey, J. G.
    ANAESTHESIA, 2013, 68 (10) : 1026 - 1032
  • [35] An Ultrasound Evaluation of Laryngeal Mask Airway Position in Pediatric Patients: An Observational Study
    Kim, Jeongmin
    Kim, Ji Young
    Kim, Won Oak
    Kil, Hae Keum
    ANESTHESIA AND ANALGESIA, 2015, 120 (02): : 427 - 432
  • [36] Novel tubeless supraglottic ventilation in a difficult paediatric airway
    Ng, Ruth
    Budiman, Maryam
    Azman, Mawaddah
    Goh, Bee-See
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2018, 34 (01) : 43 - 46
  • [37] A new supraglottic airway, the Elisha Airway Device: A preliminary study
    Vaida, SJ
    Gaitini, D
    Ben-David, B
    Somri, M
    Hagberg, CA
    Gaitini, LA
    ANESTHESIA AND ANALGESIA, 2004, 99 (01): : 124 - 127
  • [38] Repair of damaged supraglottic airway devices: A novel method
    Singh, Manpreet
    Bharti, Ritu
    Kapoor, Dheeraj
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2010, 18
  • [39] AZ Airway: a novel interchangeable supraglottic and tracheal device
    Avitsian, R.
    Zura, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 (03) : E43 - E44
  • [40] Repair of damaged supraglottic airway devices: A novel method
    Manpreet Singh
    Ritu Bharti
    Dheeraj Kapoor
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 18