Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

被引:8
|
作者
Erdem, Mehmet [1 ]
Gulabi, Deniz [2 ]
Cecen, Gultekin Sitki [2 ]
Avci, Cem Coskun [3 ]
Asci, Murat [4 ]
Saglam, Fevzi [2 ]
机构
[1] Sakarya Univ, Orthopaed & Traumatol Dept, Fac Med, Sakarya, Turkey
[2] Dr Lutfi Kirdar Kartal Training & Res Hosp, TR-34890 Istanbul, Turkey
[3] Umraniye Training & Res Hosp, Istanbul, Turkey
[4] Tokat State Hosp, Tokat, Turkey
关键词
Knee; Knee prothesis; Alignment; Fibula; CONVENTIONAL TKA; POSTERIOR SLOPE; EXTRAMEDULLARY; REPLACEMENT; NAVIGATION; GUIDES; INSTRUMENTATION; INTRAMEDULLARY; POSITION; SURGERY;
D O I
10.1007/s00167-014-2957-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1A degrees A A +/- A 0.8A degrees. The mean postoperative tibial sagittal angle measurements were 83.3A degrees A A +/- A 1.4A degrees (81A degrees-86A degrees). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5A degrees A A +/- A 3A degrees). The mean postoperative tibial coronal angle was 89.3A degrees A A +/- A 1.5A degrees. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [41] Finite element analysis of the tibial component alignment in a transverse plane in total knee arthroplasty
    Popescu, Roman
    Cristea, Stefan
    Oleksik, Valentin
    Pascu, Adrian Marius
    Haritinian, Emil George
    JOURNAL OF APPLIED BIOMEDICINE, 2021, 19 (04) : 234 - 239
  • [42] A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty
    Kawaguchi, Kohei
    Inui, Hiroshi
    Yamagami, Ryota
    Kenichi, Kono
    Sameshima, Shin
    Kage, Tomofumi
    Taketomi, Shuji
    Tanaka, Sakae
    KNEE, 2021, 29 : 323 - 331
  • [43] Tibial component positioning in total knee arthroplasty: Bone coverage and extensor apparatus alignment
    Lemaire P.
    Pioletti D.P.
    Meyer F.-M.
    Meuli R.
    Dörfl J.
    Leyvraz P.-F.
    Knee Surgery, Sports Traumatology, Arthroscopy, 1997, 5 (4) : 251 - 257
  • [44] Alignment evaluation using different distal reference points after total knee arthroplasty
    Ishii, Yoshinori
    Noguchi, Hideo
    Sato, Junko
    Takahashi, Ikuko
    Ishii, Hana
    Ishii, Ryo
    Ishii, Kei
    Toyabe, Shin-ichi
    JOURNAL OF ORTHOPAEDICS, 2021, 25 : 186 - 190
  • [45] Can Isolated Tibial Component Revision Be an Alternative to Isolated Aseptic Loosening of the Tibial Component in Total Knee Arthroplasty?
    Rodriguez-Merchan, E. Carlos
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (02): : 136 - 138
  • [46] Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle-trochlear groove can be an aid
    Zhang, He
    Cao, Chengming
    Zhang, Han
    Han, Shoujiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [47] Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty
    Stephen M. Howell
    Justin Chen
    Maury L. Hull
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2288 - 2295
  • [48] Different rotational alignment of tibial component should be selected for varied tibial tubercle locations in total knee arthroplasty
    Yike, Dai
    Tianjun, Ma
    Heyong, Yin
    Chongyang, Xu
    Hongrui, Zhang
    Ai, Guo
    Naicheng, Diao
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (09) : 3061 - 3067
  • [49] Different rotational alignment of tibial component should be selected for varied tibial tubercle locations in total knee arthroplasty
    Dai Yike
    Ma Tianjun
    Yin Heyong
    Xu Chongyang
    Zhang Hongrui
    Guo Ai
    Diao Naicheng
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 3061 - 3067
  • [50] Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty
    Howell, Stephen M.
    Chen, Justin
    Hull, Maury L.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2288 - 2295