Standardization of anal sphincter electromyography: Utility of motor unit potential parameters

被引:21
|
作者
Podnar, S [1 ]
Vodusek, DB [1 ]
机构
[1] Univ Ljubljana, Med Ctr, Div Neurol, Inst Clin Neurophysiol, SI-1525 Ljubljana, Slovenia
关键词
external anal sphincter muscle; motor unit potentials; needle electromyography; quantification; sensitivity;
D O I
10.1002/mus.1093.abs
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Advanced electromyography systems offer quantitative analysis of a number of motor unit potential (MUP) parameters. However, only limited data are available on the diagnostic usefulness of these parameters. In the present study, we compared the sensitivities of MUP parameters in revealing "neuropathic" changes in the external anal sphincter (EAS) muscles in 56 patients examined 5-240 months after damage to the cauda equina or conus medullaris. Using multi-MUP analysis, 20 MUPs were obtained from patients' EAS muscles. Their MUP parameters were compared with normative data from 64 controls. The diagnostic sensitivities of mean values/"outliers" of MUP parameters for detecting neuropathic EAS muscles were calculated (area 25%/30%; number of turns 18%/29%; size index 13%/ 24%; thickness 18%/18%; amplitude 17%/17%; spike duration 20%/9%; duration 15%/12%, number of phases 15%/11%; and their combination 51%/ 52%), Altogether, the cumulative sensitivity of multi-MUP analysis using both mean values and "outliers" was 62%. The combination of MUP parameters improves the diagnostic yield of MUP analysis, but the influence on specificity remains unknown. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:946 / 951
页数:6
相关论文
共 50 条
  • [21] Electromyography of the anal sphincter: Which muscle to examine?
    Podnar, S
    MUSCLE & NERVE, 2003, 28 (03) : 377 - 379
  • [22] The external anal sphincter and the role of surface electromyography
    Enck, P
    Hinninghofen, H
    Merletti, R
    Azpiroz, F
    NEUROGASTROENTEROLOGY AND MOTILITY, 2005, 17 : 60 - 67
  • [23] EMG of the External Anal Sphincter: Reference Values of Motor Unit Potentials
    Kittel, Martin
    Jost, Wolfgang H.
    COLOPROCTOLOGY, 2006, 28 (03) : 155 - 162
  • [24] MOTOR UNIT NUMBER ESTIMATION OF THE EXTERNAL ANAL SPHINCTER OF FEMALE RATS
    Zhang, C.
    Peng, Y.
    Munoz, A.
    Boone, T.
    Zhang, Y.
    NEUROUROLOGY AND URODYNAMICS, 2016, 35 : S415 - S416
  • [25] RELATION BETWEEN ELECTROMYOGRAPHY AND ANAL MANOMETRY OF THE EXTERNAL ANAL-SPHINCTER
    SORENSEN, M
    TETZSCHNER, T
    RASMUSSEN, OO
    CHRISTIANSEN, J
    GUT, 1991, 32 (09) : 1031 - 1034
  • [26] RELATION BETWEEN ELECTROMYOGRAPHY AND ANAL MANOMETRY OF THE EXTERNAL ANAL-SPHINCTER
    PAPACHRYSOSTOMOU, M
    BINNIE, NR
    SMITH, AN
    GUT, 1992, 33 (05) : 718 - 718
  • [27] Diagnostic significance of urethral sphincter electromyography and external anal sphincter electromyography in patients with multiple system atrophy
    Qiu, F.
    Qi, X.
    Li, L.
    Liu, J.
    EUROPEAN JOURNAL OF NEUROLOGY, 2012, 19 : 127 - 127
  • [28] External anal sphincter electromyography in the differential diagnosis of parkinsonism
    Rodi, Z
    Denislic, M
    Vodusek, DB
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1996, 60 (04): : 460 - 461
  • [29] Criteria for neuropathic abnormality in quantitative anal sphincter electromyography
    Podnar, S
    MUSCLE & NERVE, 2004, 30 (05) : 596 - 601
  • [30] ANAL SPHINCTER ELECTROMYOGRAPHY IN FIRST 2 YEARS OF LIFE
    WAYLONIS, GW
    ASEFF, JN
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1973, 54 (11): : 525 - 527