Parafoveal Retinal Vessel Density Assessment by Optical Coherence Tomography Angiography in Healthy Eyes

被引:22
|
作者
Arya, Malvika [1 ]
Rebhun, Carl B. [1 ]
Alibhai, A. Yasin [1 ]
Chen, Xuejing [1 ]
Moreira-Neto, Carlos [2 ]
Baumal, Caroline R. [1 ]
Reichel, Elias [1 ]
Witkin, Andre J. [1 ]
Duker, Jay S. [1 ]
Sadda, SriniVas R. [3 ]
Waheed, Nadia K. [1 ]
机构
[1] Tufts Med Ctr, New England Eye Ctr, 260 Tremont St,Biewend Bldg,9-11th Floor, Boston, MA 02116 USA
[2] Hosp Olhos Parana, Curitiba, Parana, Brazil
[3] Univ Calif Los Angeles, David Geffen Sch Med, Doheny Eye Inst, Los Angeles, CA 90095 USA
来源
关键词
FOVEAL AVASCULAR ZONE; SWEPT-SOURCE; CHOROIDAL NEOVASCULARIZATION; QUANTITATIVE-ANALYSIS; CAPILLARY DENSITY; RETINOPATHY; REPRODUCIBILITY; OCCLUSION; IMPACT;
D O I
10.3928/23258160-20180814-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To assess variability in vessel density (VD) measurements across three optical coherence tomography angiography (OCTA) devices to identify a methodology that offers the least amount of variation in VD, and to assess the effect of averaging of multiple scans on VD variability. PATIENTS AND METHODS: Fifteen eyes of eight healthy individuals were imaged consecutively on three OCTA devices. Segmentations at the superficial, deep, and full retinal layers were generated. Repeat scans for each retinal layer were registered and averaged to generate one OCTA image. Two different automated thresholding techniques were used to calculate vessel area density (VAD) from binarized images and vessel skeleton density (VSD) from skeletonized images. Vessel length, a linear measure of the combined lengths of vessels, was calculated. Foveal avascular zone (FAZ) area was measured. RESULTS: All three OCTA devices were significantly different (P < .0001). This finding remained after averaging images (P < .0001). VSD was more repeatable within a device but less reproducible across devices. Conversely, VAD demonstrated less repeatability but greater reproducibility. Differences in VSD between devices were systematic and attributable to differences in resolution. Vessel length, unaffected by resolution, demonstrated no significant differences between the devices (P > .107). There was no significant difference in FAZ area across devices (P = .51). After averaging images, VD was significantly different from the single images for each device and plexus (P < .05) but remained within 1% of the value of a single scan. CONCLUSIONS: OCTA devices show variability in VD for healthy individuals. With greater repeatability, VSD appeared useful for following a patient on one device. VAD and vessel length seemed ideal for comparing vessel parameters between OCTA devices. After averaging multiple scans, VSD remained within 1% of a single scan, for which clinical significance remains to be determined. Caution is advised when comparing quantitative analyses across OCTA devices.
引用
收藏
页码:S5 / S17
页数:13
相关论文
共 50 条
  • [41] Measurements of the superficial retinal capillary net in healthy eyes using Optical Coherence Tomography Angiography
    Neves, Catarina A.
    Soares, Mario
    An, Lin
    Alves, Dalila
    Laron, Michal
    Santos, Torcato
    Durbin, Mary K.
    Cunha-Vaz, Jose G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [42] IMPACT OF PUPIL DILATION ON RETINAL MICROVASCULATURE IN HEALTHY EYES USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY
    Villatoro, George
    Manalastas, Patricia Isabel C.
    Hasenstab, Kyle
    Khoa Dinh Nguyen
    Bowd, Christopher
    Hou, Huiyuan
    Li, Andrew J.
    Penteado, Rafaella
    Moghimi, Sasan
    Ghahari, Elham
    Weinreb, Robert N.
    Zangwill, Linda M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [43] A Method for Quantitative Assessment of Retinal Vessel Tortuosity Imaged by Optical Coherence Tomography Angiography
    Khansari, Maziyar M.
    Lim, Jennifer I.
    Shahidi, Mahnaz
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [44] PARAFOVEAL MICROVASCULAR FEATURES ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN EYES WITH CIRCUMSCRIBED CHOROIDAL HEMANGIOMA
    Sioufi, Kareem
    Say, Emil A. T.
    Ferenczy, Sandor C.
    Shields, Carol L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (06): : 1091 - 1099
  • [45] Deep Learning Image Analysis of Optical Coherence Tomography Angiography Measured Vessel Density Improves Classification of Healthy and Glaucoma Eyes
    Bowd, Christopher
    Belghith, Akram
    Zangwill, Linda M.
    Christopher, Mark
    Goldbaum, Michael H.
    Fan, Rui
    Rezapour, Jasmin
    Moghimi, Sasan
    Kamalipour, Alireza
    Hou, Huiyuan
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 236 : 298 - 308
  • [46] Inter-eye Asymmetry of Optical Coherence Tomography Angiography Vessel Density in Bilateral Glaucoma, Glaucoma Suspect, and Healthy Eyes
    Hou, Huiyuan
    Moghimi, Sasan
    Zangwill, Linda M.
    Shoji, Takuhei
    Ghahari, Elham
    Manalastas, Patricia Isabel C.
    Penteado, Rafaella C.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 190 : 69 - 77
  • [47] Topographic Variation of Retinal Vascular Density in Normal Eyes Using Optical Coherence Tomography Angiography
    Park, Michael M.
    Young, Benjamin K.
    Shen, Liangbo L.
    Adelman, Ron A.
    Del Priore, Lucian, V
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (12):
  • [48] Optical coherence tomography angiography changes in the three parafoveal retinal plexuses in response to hyperoxia
    Hagag, Ahmed M.
    Pechauer, Alex David
    Liu, Liang
    Wang, Jie
    Miao, Zhang
    Jia, Yali
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [49] Impact of image averaging on vessel detection using optical coherence tomography angiography in eyes with macular oedema and in healthy eyes
    Le Boite, Hugo
    Chetrit, Mardoche
    Erginay, Ali
    Bonnin, Sophie
    Lavia, Carlo
    Tadayoni, Ramin
    Couturier, Aude
    PLOS ONE, 2021, 16 (10):
  • [50] Assessment of superficial and deep retinal vessel density in systemic lupus erythematosus patients using optical coherence tomography angiography
    Arfeen, Shaimaa A.
    Bahgat, Nermeen
    Adel, Nehal
    Eissa, Mervat
    Khafagy, Mohamed M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (06) : 1261 - 1268