Methodology of a dynamic test bench to test ultra-high-frequency transponder ear tags in motion

被引:4
|
作者
Hammer, Nora [1 ]
Adrion, Felix [1 ]
Jezierny, Dagmar [1 ]
Gallmann, Eva [1 ]
Jungbluth, Thomas [1 ]
机构
[1] Univ Hohenheim, Inst Agr Engn, Livestock Syst Engn, D-70593 Stuttgart, Germany
关键词
Radio-frequency identification; Ultra-high-frequency; Test bench; Ear tags; Transponder; Animal identification; ELECTRONIC IDENTIFICATION; TRACEABILITY; PATTERNS; SYSTEMS; PIGS; SOWS;
D O I
10.1016/j.compag.2015.02.003
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The electronic identification of sheep and goats has been obligatory in the European Union since 2010 by means of low-frequency radio-frequency identification systems. The identification of pigs and cattle is currently based on a visual ear tag, but electronic animal identification is gaining in importance. The European Union already offers the additional use of electronic identification systems for cattle in their council regulation. Besides the low-frequency radio-frequency identification, an ultra-high-frequency ear tag is a possibility for electronic animal identification. The benefits of the latter frequency band are the high range, the possibility of quasi-simultaneous reading and a high data transmission rate. First systematic laboratory tests were carried out before testing the ear tags in practice. Therefore, a dynamic test bench was built. The aim of the experiments presented in this study was to compare different ear tags under standardised conditions and select the most suitable for practical use. The influence of different parameters was tested and a standard test procedure to evaluate the quality of the transponder ear tag was developed. The experiments showed that neither the transponder holder material (polyvinyl chloride vs. extruded polystyrene) nor the reader settings examined (triggered read vs. presence sensing) had a significant influence on the average of readings of the different transponder types. The parameter number of rounds' (10 vs. 15 vs. 20) did not show a significant effect either. However, significant differences between speed (1.5 m s(-1), 3.0 m s(-1)), transponder orientation and the fourteen transponder types were found. The two most suitable transponder ear tags for cattle and pigs have been determined by comparison. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:81 / 92
页数:12
相关论文
共 50 条
  • [31] High and Low Temperature Performance Test of Asphalt Based on Dynamic Shear Time and Frequency Scanning
    Lin J.
    Liang H.
    Fan L.
    2018, Tongji University (21): : 516 - 522
  • [32] Optical High Frequency Test Structure and Test Bench definition for on Wafer Silicon Integrated Noise Source characterization up to 110 GHz based on Germanium-on-Silicon Photodiode
    Oeuvrard, S.
    Lampin, J. -F.
    Ducournau, G.
    Virot, L.
    Fedeli, J. M.
    Hartmann, J. M.
    Danneville, F.
    Morandini, Y.
    Gloria, D.
    2013 IEEE INTERNATIONAL CONFERENCE ON MICROELECTRONIC TEST STRUCTURES (ICMTS), 2013, : 73 - 76
  • [33] Bench test assessment of dosage accuracy and measurement inaccuracy in nitric oxide inhalational therapy during high frequency oscillatory ventilation
    Markhorst, DG
    Leenhoven, T
    van Genderingen, HR
    Uiterwijk, JW
    van Vught, AJ
    JOURNAL OF CLINICAL MONITORING, 1997, 13 (06) : 349 - 355
  • [34] Bench Test Assessment of Dosage Accuracy and Measurement Inaccuracy in Nitric Oxide Inhalational Therapy During High Frequency Oscillatory Ventilation
    Department of Pediatrics, University Hospital Vrije Universiteit, Amsterdam, Netherlands
    不详
    不详
    不详
    J. Clin. Monit. Comput., 6 (349-355):
  • [35] High-Frequency Time Domain Source Path Contribution: From Engine Test Bench Data to Cabin Interior Sounds
    Bogema, David
    Schuhmacher, Andreas
    Newton, Gary
    Vanhaaften, Frederick
    Abe, Takeshi
    Tcherniak, Dmitri
    Cheng, Ming
    Lee, Ming-Ran
    SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS, 2013, 6 (02): : 1293 - 1299
  • [36] Bench Test Assessment of Dosage Accuracy and Measurement Inaccuracy in Nitric Oxide Inhalational Therapy During High Frequency Oscillatory Ventilation
    Dick G. Markhorst
    Tom Leenhoven
    Huib R. van Genderingen
    Jan W. Uiterwijk
    A. Johannes van Vught
    Journal of Clinical Monitoring, 1997, 13 : 349 - 355
  • [37] Design and Simulation Analysis of Dynamic State Test Bench of Shaft Tip Earthing Device in High-Speed Railway Vehicle
    Luo, Qi
    Zheng, Zhiwei
    Liu, Shihui
    Chen, Rong
    Shi, Zheyu
    Xu, Guan
    CONFERENCE PROCEEDINGS OF 2019 5TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND ROBOTICS (ICCAR), 2019, : 673 - 677
  • [38] Ultra-high frequency lung ultrasound in preterm neonates: a test validation study on interpretation agreement and reliability
    Sartorius, Victor
    Loi, Barbara
    Vivalda, Laura
    Regiroli, Giulia
    Ortega, Sofia de la Rubia
    Centorrino, Roberta
    De Luca, Daniele
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2023, 108 (06): : F607 - F611
  • [39] The Effects of Item Composition, Tag Inlay Design, Reader Antenna Polarization, Power and Transponder Orientation on the Dynamic Coupling Efficiency of Backscatter Ultra-High Frequency Radio Frequency Identification
    Mc Carthy, Ultan
    Ayalew, Gashaw
    Butler, Francis
    McDonnell, Kevin
    Ward, Shane
    PACKAGING TECHNOLOGY AND SCIENCE, 2009, 22 (04) : 241 - 248
  • [40] Computer modelling and vegetable bench test of a bipolar electrode array intended for use in high frequency irreversible electroporation treatment of skin cancer
    Gonzalez-Suarez, Ana
    Kerrigan, Cian
    McNamara, Jason
    Kinsella, Sean
    Duffy, Maeve
    BIOMEDICAL ENGINEERING LETTERS, 2025, 15 (01) : 69 - 79