Comparative studies of glycoprotein Ib in heparin coated and nonheparin coated extracorporeal circulation circuits

被引:1
|
作者
Hioki, I
Yada, I
Nishikawa, M
Shomura, Y
Cruz, BP
Onoda, K
Tani, K
Shimono, T
Shinpo, H
机构
[1] Mie Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Tsu, Mie 5148507, Japan
[2] Mie Univ, Sch Med, Dept Internal Med 2, Tsu, Mie 5148507, Japan
关键词
D O I
10.1097/00002480-199809000-00014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contact between blood and artificial materials has various effects on blood. Impairment of platelet function is an especially important and well known effect, but its precise mechanism is not clearly understood. The authors constructed a circulation model to investigate the effect of extracorporeal circulation on platelet membrane glycoproteins (CPs), especially GP Ib, and to compare the changes in CP Ib in heparin coated (group C) and nonheparin coated (group N) circuits. As determined by flow cytometry, CP Ib in both groups decreased on initiating circulation, but the decrease in group N was significantly larger than that in group C. There was no observed change in GP IIb/IIIa levels in either group. The extent of shear stress induced platelet aggregation significantly decreased during circulation in both groups. Decreases in the extent of shear stress induced platelet aggregation were significantly less with the use of heparin coated circuits. In addition, the amount of CP Ib in the high speed pellet decreased progressively during circulation in both groups. In contrast, the amount of GP Ib in the Triton insoluble (low speed) pellet increased dramatically during circulation. However, expression of CP Ib in the Triton soluble platelet fraction was low in both groups. From the results, it was concluded that the cause of the decrease in platelet function during extracorporeal circulation is attributable to the internalization of CP Ib from the platelet surface inside the platelet. It also can be said that a heparin coated circuit is one effective means of controlling this change.
引用
收藏
页码:M397 / M400
页数:4
相关论文
共 50 条
  • [1] Comparative studies of glycoprotein Ib in heparin coated and nonheparin coated extracorporeal circulation circuits
    Hioki, Iwao
    Yada, Isao
    Nishikawa, Masakatsu
    Shomura, Yu
    Cruz, Bayardo Pagoada
    Onoda, Koji
    Tani, Kazuhiro
    Shimono, Takatsugu
    Shinpo, Hideto
    ASAIO Journal, 44 (05):
  • [2] Biocompatibility in heparin-coated extracorporeal circuits
    Hsu, Li-Chien
    PERFUSION-UK, 1996, 11 (03): : 256 - 263
  • [3] BIOCOMPATIBILITY OF EXTRACORPOREAL-CIRCULATION - INVITRO COMPARISON OF HEPARIN-COATED AND UNCOATED OXYGENATOR CIRCUITS
    VIDEM, V
    MOLLNES, TE
    GARRED, P
    SVENNEVIG, JL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 101 (04): : 654 - 660
  • [4] Clinical evaluation of Duraflo(R) II heparin treated extracorporeal circulation circuits (2nd version) - The European working group on heparin coated extracorporeal circulation circuits
    Wildevuur, CRH
    Jansen, PGM
    Bezemer, PD
    Kuik, DJ
    Eijsman, L
    Bruins, P
    DeJong, AP
    VanHardevelt, FWJ
    Biervliet, JD
    Hasenkam, JM
    Kure, HH
    Knudsen, L
    Bellaiche, L
    Ahlburg, P
    Loisance, DY
    Baufreton, C
    LeBesnerais, P
    Bajan, G
    Matta, A
    VanDyck, M
    Renotte, MT
    PonlotLois, A
    Baele, P
    McGovern, EA
    McCarthy, J
    McCarthy, A
    ODonnell, A
    Fosse, E
    Moen, O
    Dregelid, E
    Brockmeier, V
    Anderson, C
    Pomar, JL
    Ranucci, M
    Conti, D
    Cirri, S
    Conti, E
    Ditta, A
    VonSegesser, LK
    Tkebuchava, T
    Weiss, BM
    Turina, MI
    Svennevig, JL
    Mohr, B
    Videm, V
    Karlsen, H
    Pedersen, TH
    Thelin, S
    Halden, E
    Hagman, L
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (04) : 616 - 623
  • [5] Descending thoracic aortic aneurysm repair with the aid of partial cardiopulmonary bypass: Heparin-coated circuits versus nonheparin-coated circuits
    Morishita, K
    Kawaharada, N
    Fukada, J
    Hachiro, Y
    Kurimoto, Y
    Fujisawa, Y
    Saito, T
    Abe, T
    ARTIFICIAL ORGANS, 2005, 29 (04) : 300 - 305
  • [6] HEPARIN-COATED VERSUS NON-COATED SURFACES FOR EXTRACORPOREAL-CIRCULATION
    MOTTAGHY, K
    OEDEKOVEN, B
    POPPEL, K
    KOVACS, B
    KIRSCHFINK, M
    BRUCHMULLER, K
    KASHEFI, A
    GEISEN, C
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11): : 721 - 728
  • [7] Specific complement inhibition with heparin-coated extracorporeal circuits
    Velthuis, HT
    Jansen, PGM
    Hack, CE
    Eijsman, L
    Wildevuur, CRH
    ANNALS OF THORACIC SURGERY, 1996, 61 (04): : 1153 - 1157
  • [8] Impact of Heparin- or Nonheparin-Coated Circuits on Platelet Function in Pediatric Cardiac Surgery
    Giorni, Chiara
    Pezzella, Chiara
    Bojan, Mirela
    Ricci, Zaccaria
    Pouard, Philippe
    Raisky, Olivier
    Tourneur, Laurent
    La Salvia, Ondina
    Favia, Isabella
    Borgel, Delphine
    Cogo, Paola
    Carotti, Adriano
    Lasne, Dominique
    ANNALS OF THORACIC SURGERY, 2019, 107 (04): : 1241 - 1247
  • [9] Activation of the clotting system:: heparin-coated versus non coated systems for extracorporeal circulation
    Urlesberger, B
    Zobel, G
    Rödl, S
    Dacar, D
    Friehs, I
    Leschnik, B
    Muntean, W
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (12): : 708 - 712
  • [10] Activity of anticoagulant proteins on the polymer-coated and heparin-coated membranes in an extracorporeal circulation circuit
    Tagaya, Masashi
    Murataka, Takuo
    Okano, Shinya
    Handa, Hiroki
    Tanaka, Yuri
    Takahashi, Shunsuke
    PERFUSION-UK, 2023, 38 (03): : 600 - 608