Effect of platform switching on peri-implant bone levels: a randomized clinical trial

被引:67
|
作者
Enkling, Norbert [1 ]
Joehren, Peter [2 ]
Klimberg, Victoria
Bayer, Stefan [3 ]
Mericske-Stern, Regina
Jepsen, Soren [4 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Witten Herdecke, Dept Oral Surg, Witten, Germany
[3] Univ Bonn, Dept Prosthet Dent Propaedeut & Mat Sci, D-5300 Bonn, Germany
[4] Univ Bonn, Dept Periodontol Operat & Prevent Dent, D-5300 Bonn, Germany
关键词
bacteria; bone level; bone loss; dental implants; implant design; platform switching; SUBMERGED TITANIUM IMPLANTS; HISTOMETRIC EVALUATION; DENTAL IMPLANTS; RELIABILITY; MICROGAP; DOGS; RESTORATIONS; RADIOGRAPHY; DENTISTRY; ACCURACY;
D O I
10.1111/j.1600-0501.2010.02090.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The concept of platform switching has been introduced to implant dentistry based on observations of reduced peri-implant bone loss. However, randomized clinical trials are still lacking. This study aimed to test the hypothesis that platform switching has a positive impact on crestal bone-level changes. Material and methods: Two implants with diameters of 4mm were inserted epicrestally into one side of the posterior mandibles of 25 subjects. After 3 months of submerged healing, the reentry surgery was performed. On the randomly placed test implant, an abutment 3.3mm in diameter was mounted, resulting in a horizontal circular step of 0.35mm (platform switching). The control implant was straight, with an abutment 4mm in diameter. Single-tooth crowns were cemented provisionally. All patients were monitored at short intervals over the course of 1 year. Standardized radiographs and microbiological samples from the implants' inner spaces were obtained at baseline (implant surgery), and after 3, 4, and 12 months. Results: After 1 year, the mean radiographic vertical bone loss at the test implants was 0.53 +/- 0.35mm and at the control implants, it was 0.58 +/- 0.55 mm. The mean intraindividual difference was 0.05 +/- 0.56 mm, which is significantly <0.35mm (P = 0.0093, post hoc power 79.9%). The crestal bone-level changes depended on time (P<0.001), but not on platform switching (P = 0.4). The implants' internal spaces were contaminated by bacteria, with no significant differences in the total counts between the test and the control at any time point (P = 0.98). Conclusions: The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant bone loss at implants restored according to the concept of platform switching.
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 50 条
  • [31] Multivariate analysis of the effect of keratinized mucosa on peri-implant tissues with platform switching: A retrospective study
    Suzuki, Azusa
    Nakano, Tamaki
    Inoue, Masaki
    Isigaki, Shoichi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (03) : 592 - 603
  • [32] Erythritol powder airflow for the treatment of peri-implant mucositis: A randomized controlled clinical trial
    Corbella, Stefano
    Radaelli, Katherine
    Alberti, Alice
    Francetti, Luca
    Taschieri, Silvio
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2024, 22 (04) : 982 - 990
  • [33] Treatment of peri-implant mucositis with a chitosan brush-A pilot randomized clinical trial
    Wohlfahrt, Johan Caspar
    Aass, Anne M.
    Koldsland, Odd C.
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2019, 17 (02) : 170 - 176
  • [34] Randomized Controlled Study on Effect of Concentrated Growth Factors on Crestal Bone Levels and Peri-implant Bone Density in Dental Implants
    Karthik, V. C.
    Prabhu, K.
    Bharath, N.
    Shobana, P.
    Indhu, K.
    Abraham, Sonia
    Arunalakshmi, K.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 68 - 77
  • [35] Reconstruction of Peri-implant Osseous Defects: A Multicenter Randomized Trial
    Jepsen, K.
    Jepsen, S.
    Laine, M. L.
    Moin, D. Anssari
    Pilloni, A.
    Zeza, B.
    Sanz, M.
    Ortiz-Vigon, A.
    Roos-Jansaker, A. M.
    Renvert, S.
    JOURNAL OF DENTAL RESEARCH, 2016, 95 (01) : 58 - 66
  • [36] Influence of the abutment height and connection timing in early peri-implant marginal bone changes: A prospective randomized clinical trial
    Borges, Tiago
    Leitao, Bruno
    Pereira, Miguel
    Carvalho, Agata
    Galindo-Moreno, Pablo
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 907 - 914
  • [37] MicroRNAs in Peri-implant Crevicular Fluid Can Predict Peri-implant Bone Resorption: Clinical Trial with a 5-Year Follow-up
    Menini, Maria
    Pesce, Paolo
    Pera, Francesco
    Baldi, Domenico
    Pulliero, Alessandra
    Izzotti, Alberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (06) : 1148 - 1157
  • [38] Effect of surgical techniques on primary implant stability and peri-implant bone
    Fanuscu, Mete I.
    Chang, Ting-Ling
    Akca, Kivanc
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (12) : 2487 - 2491
  • [39] Effect of implant surface roughness and loading on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Sloten, Jozef Vander
    Puers, Robert
    Duyck, Joke
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 150 - 157
  • [40] Comparative clinicoradiographical evaluation of effect of aminobisphosphonate (sodium alendronate) on peri-implant bone status: Controlled clinical trial
    Aggarwal, Rajni
    Babaji, Prashant
    Nathan, S. Senthil
    Attokaran, George
    Kumar, S. M. Santosh
    Sathnoorkar, Sharanpriya
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (04): : 285 - 290