Effect of platform switching on peri-implant bone levels: a randomized clinical trial

被引:67
|
作者
Enkling, Norbert [1 ]
Joehren, Peter [2 ]
Klimberg, Victoria
Bayer, Stefan [3 ]
Mericske-Stern, Regina
Jepsen, Soren [4 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Witten Herdecke, Dept Oral Surg, Witten, Germany
[3] Univ Bonn, Dept Prosthet Dent Propaedeut & Mat Sci, D-5300 Bonn, Germany
[4] Univ Bonn, Dept Periodontol Operat & Prevent Dent, D-5300 Bonn, Germany
关键词
bacteria; bone level; bone loss; dental implants; implant design; platform switching; SUBMERGED TITANIUM IMPLANTS; HISTOMETRIC EVALUATION; DENTAL IMPLANTS; RELIABILITY; MICROGAP; DOGS; RESTORATIONS; RADIOGRAPHY; DENTISTRY; ACCURACY;
D O I
10.1111/j.1600-0501.2010.02090.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The concept of platform switching has been introduced to implant dentistry based on observations of reduced peri-implant bone loss. However, randomized clinical trials are still lacking. This study aimed to test the hypothesis that platform switching has a positive impact on crestal bone-level changes. Material and methods: Two implants with diameters of 4mm were inserted epicrestally into one side of the posterior mandibles of 25 subjects. After 3 months of submerged healing, the reentry surgery was performed. On the randomly placed test implant, an abutment 3.3mm in diameter was mounted, resulting in a horizontal circular step of 0.35mm (platform switching). The control implant was straight, with an abutment 4mm in diameter. Single-tooth crowns were cemented provisionally. All patients were monitored at short intervals over the course of 1 year. Standardized radiographs and microbiological samples from the implants' inner spaces were obtained at baseline (implant surgery), and after 3, 4, and 12 months. Results: After 1 year, the mean radiographic vertical bone loss at the test implants was 0.53 +/- 0.35mm and at the control implants, it was 0.58 +/- 0.55 mm. The mean intraindividual difference was 0.05 +/- 0.56 mm, which is significantly <0.35mm (P = 0.0093, post hoc power 79.9%). The crestal bone-level changes depended on time (P<0.001), but not on platform switching (P = 0.4). The implants' internal spaces were contaminated by bacteria, with no significant differences in the total counts between the test and the control at any time point (P = 0.98). Conclusions: The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant bone loss at implants restored according to the concept of platform switching.
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 50 条
  • [1] Effect of implant macrogeometry on peri-implant healing outcomes: a randomized clinical trial
    Luiz Carlos do Carmo Filho
    Fernanda Faot
    Marina de Matos Madruga
    Raissa Micaella Marcello-Machado
    Dimorvan Bordin
    Altair Antoninha Del Bel Cury
    Clinical Oral Investigations, 2019, 23 : 567 - 575
  • [2] Effect of implant macrogeometry on peri-implant healing outcomes: a randomized clinical trial
    do Carmo Filho, Luiz Carlos
    Faot, Fernanda
    Madruga, Marina de Matos
    Marcello-Machado, Raissa Micaella
    Bordin, Dimorvan
    Del Bel Cury, Altair Antoninha
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) : 567 - 575
  • [3] Abutment height influences the effect of platform switching on peri-implant marginal bone loss
    Galindo-Moreno, Pablo
    Leon-Cano, Ana
    Monje, Alberto
    Ortega-Oller, Inmaculada
    O'Valle, Francisco
    Catena, Andres
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : 167 - 173
  • [4] Influence of Abutment Design and Platform Switching on Peri-implant Marginal Bone Level: A Randomized Controlled Clinical Trial with 1-Year Results
    Cardaropoli, Daniele
    Tamagnone, Lorenzo
    Roffredo, Alessandro
    Gaveglio, Lorena
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2021, 41 (04) : 547 - +
  • [5] The Effect of Platform-Switching Plus Laser Grooving on Peri-implant Hard and Soft Tissue Level: A Randomized, Controlled, Blinded Clinical Trial
    Lowy, Jeremy
    Kwon, Hyuk Sang
    Patel, Abhishek
    Greenwell, Henry
    Hill, Margaret
    Katwal, Diksha
    Rademacher, Anthony Charles
    Mendoza, Juan
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2019, 39 (05) : 669 - 674
  • [6] Influence of abutment disconnection on peri-implant marginal bone loss: A randomized clinical trial
    Praca, Luciano de Freitas Guimaraes
    Teixeira, Renata Cordeiro
    Rego, Rodrigo Otavio
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (04) : 341 - 351
  • [7] Effect of the Platform-Switching Technique on Preservation of Peri-implant Marginal Bone: A Systematic Review
    Al-Nsour, Maram M.
    Chan, Hsun-Liang
    Wang, Hom-Lay
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 138 - 145
  • [8] Effect of platform switching on peri-implant bone: A 3D finite element analysis
    Aslam, Ayesha
    Hassan, Syed Hammad
    Aslam, Hammad Mudasser
    Khan, Danish Azeem
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06): : 935 - 940
  • [9] Platform-Switching to Preserve Peri-Implant Bone: A Meta-Analysis
    Aslam, Ayesha
    Ahmed, Bilal
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2016, 26 (04): : 315 - 319
  • [10] The effect of one-time abutment placement on interproximal bone levels and peri-implant soft tissues: a prospective randomized clinical trial
    Molina, Ana
    Sanz-Sanchez, Ignacio
    Martin, Conchita
    Blanco, Juan
    Sanz, Mariano
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (04) : 443 - 452