Fire Response of Steel Column Trees with End-Plate Connections

被引:4
|
作者
Rezaeian, Abbas [1 ]
Eghbali, Sobhan [1 ]
机构
[1] Shahid Chamran Univ Ahvaz, Dept Civil Engn, Ahvaz 6135741135, Iran
关键词
Column-tree; Moment-resisting frame; End-plate connection; Steel beam; Fire test; Elevated temperature; BEHAVIOR; BEAMS; BOLTS; ASSEMBLIES; JOINTS;
D O I
10.1061/(ASCE)ST.1943-541X.0003139
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of experimental research on the fire response of steel beams and their end-plate connections in column-tree moment-resisting frames (CMRFs). Using subframe assembly, full-scale steel beams with different stub-to-link end-plate connections were tested under a standard fire curve. The failure modes as well as the structural and thermal responses of the beam and the end-plate connections were studied. The influence of critical factors, including bolt grade and flange plate's size, were investigated. The findings of the experimental studies indicate that the beam flexural failure occurs at the temperature of 720 degrees C when deflections surpass the limiting value specified in a relevant British Standard Institution standard. The end-plate connections fail when the temperature exceeds 760 degrees C, while the beam experiences deflections larger than span/20. The results also show that the plate bending, the bolt tensile fracture, and thread stripping control the failure of the end-plate connection in fire conditions. The end-plate connection detail has a considerable effect on the fire performance of the beam, e.g., using Grade 8.8 bolts and thicker plates in the end-plate connection can enhance the fire resistance and rating of the beams and their connections in steel CMRFs.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Evaluation of the Behavior of Steel-Concrete Composite Flush End-Plate Connections at Ambient Temperature and in a Fire Situation
    Nicoletti, Renato Silva
    de Carvalho, Adriano Silva
    de Souza, Alex Sander Clemente
    Almeida, Saulo Jose de Castro
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (10) : 13231 - 13260
  • [42] Numerical study on seismic behaviors of steel frame end-plate connections
    Wang, Meng
    Shi, Yongjiu
    Wang, Yuanqing
    Shi, Gang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 90 : 140 - 152
  • [43] Ultimate behaviour and rotation capacity of stainless steel end-plate connections
    Song, Yuchen
    Uy, Brian
    Li, Dongxu
    Wang, Jia
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (04): : 569 - 590
  • [45] Finite element analysis of flush end-plate connections connected to column web
    Mahmood Md Tahir
    Irwan Juki
    Lee Hong Yong
    Shahrin Mohammad
    Shek Poi Ngian
    International Journal of Steel Structures, 2011, 11 : 247 - 258
  • [46] Design charts for end-plate beam-to-column steel joints
    D'Alessandro, Elisabetta
    Brando, Giuseppe
    De Matteis, Gianfranco
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2018, 171 (06) : 444 - 462
  • [47] Effect of sfiffene on behaviour of beam to column extended end-plate connection in fire
    Hao, Shu-Ying
    Dong, Jin-Hao
    Ye, Jin-Duo
    Gongcheng Lixue/Engineering Mechanics, 2010, 27 (08): : 152 - 155
  • [48] Calibration of a finite element model for isolated bolted end-plate steel connections
    Bursi, OS
    Jaspart, JP
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1997, 44 (03) : 225 - 262
  • [49] Study on Damage Index for Beam-Column Joints with Flush End-Plate Connections
    Su, Jizhi
    Zhou, Jinpu
    Liu, Weiran
    Li, Yong
    Yu, Haifeng
    Li, Qilian
    BUILDINGS, 2024, 14 (11)
  • [50] Investigating the behaviour of steel end-plate connections with shape memory alloy bolts
    Ghamari, Ali
    Amini, Seyed Majid
    De Crescenzo, Carmen
    Musmarra, Dino
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2023, 176 (02) : 131 - 146