Survivorship of Ceramic-on-Ceramic Total Hip Arthroplasty With Metal-Backed Acetabular Liners at 10 Years

被引:6
|
作者
Wagner, Moritz [1 ]
Schonthaler, Hannes [1 ]
Endstrasser, Franz [1 ]
Neururer, Sabrina [2 ]
Leitner, Hermann [2 ]
Brunner, Alexander [1 ]
机构
[1] Bezirkskrankenhaus St Johann Tirol, Dept Orthopaed & Traumatol, Bahnhofstr 14, A-6380 St Johann In Tirol, Tyrol, Austria
[2] Tirol Kliniken GmbH, Dept Clin Epidemiol, Innsbruck, Tyrol, Austria
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 10期
关键词
THA; BIOLOX; ceramic; metal-backed; mal-seating; liner;
D O I
10.1016/j.arth.2021.05.038
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic bearings are becoming increasingly popular in primary total hip arthroplasty (THA). To enhance ceramic-on-ceramic liner exchange in case of revision surgery, metal backed liner systems have been proposed. Little is known about the clinical performance of these implants. The purpose of this study is to evaluate a metal-backed liner implant system for primary THA. Methods: A total of 422 patients (with 468 consecutive THAs) were followed over a mean period of 10 years. All arthroplasties were performed with a cementless stem, a press -fit cup, and a metal-backed liner system. Surgical and clinical data, complications, and revisions were analyzed. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) before surgery and at 1 and 10 years after surgery were compared. Results: The overall 10-year implant survival rate was 93.8%. The survival rate was 97.0% for heads and liners, 97.5% for stem, and 99.3% for acetabular cup. The most common reason for revision was ceramic breakage (2.4%) of the third-generation (BIOLOX forte) acetabular liner. Mean WOMAC score improved significantly from 50.1 before surgery to 13.2 at 1 year after surgery. There was no difference in WOMAC scores between surgical approach and type of bearing at 1 and 10 years after surgery. Conclusion: THA using cementless stem, press -fit cup, and metal-backed liner system provides satisfactory long-term outcomes, with revision rate comparable to that with other systems available in the market. The metal-backed liner system has low risk of mal-seating. Third-generation ceramic liners should be avoided as they seem to be more prone to breakage. (c) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:3507 / 3512
页数:6
相关论文
共 50 条
  • [31] Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component
    Hasegawa, M.
    Sudo, A.
    Uchida, A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07): : 877 - 882
  • [32] Incidence of 'Squeaking' After Ceramic-on-Ceramic Total Hip Arthroplasty
    Mai, Kenny
    Verioti, Christopher
    Ezzet, Kace A.
    Copp, Steven N.
    Walker, Richard H.
    Colwell, Clifford W., Jr.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 413 - 417
  • [33] Squeaking in a Delta Ceramic-on-Ceramic Uncemented Total Hip Arthroplasty
    Buttaro, Martin A.
    Zanotti, Gerardo
    Comba, Fernando M.
    Piccaluga, Francisco
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1257 - 1259
  • [34] Arthrosynovial cyst of the hip after total hip arthroplasty with a ceramic-on-ceramic interface
    Legaye, J
    Lenfant, P
    Delos, M
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (05): : 475 - 478
  • [35] Can Squeaking With Ceramic-On-Ceramic Hip Articulations In Total Hip Arthroplasty Be Avoided?
    Kiyama, Takahiko
    Kinsey, Tracy L.
    Mahoney, Ormonde M.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (06): : 1015 - 1020
  • [36] Component positioning and ceramic damage in cementless ceramic-on-ceramic total hip arthroplasty
    Castagnini, Francesco
    Valente, Giordano
    Crimi, Gianluigi
    Taddei, Fulvia
    Bordini, Barbara
    Stea, Susanna
    Toni, Aldo
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (04) : 643 - 651
  • [37] Fracture of a ceramic femoral head after ceramic-on-ceramic total hip arthroplasty
    Malillos Toran, Manuel
    Cuenca, Jorge
    Antonio Martinez, Angel
    Herrera, Antonio
    Vicente Thomas, Javier
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1072 - 1073
  • [38] Use of ceramic-on-ceramic bearing in total hip arthroplasty for posttraumatic arthritis of the hip
    Lee, Young-Kyun
    Kim, Ki-Choul
    Kim, Jin-Woo
    Ha, Joo Hyung
    Yoon, Byung-Ho
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [39] Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty
    Baruffaldi, Fabio
    Mecca, Rosaria
    Stea, Susanna
    Beraudi, Alina
    Bordini, Barbara
    Amabile, Marilina
    Sudanese, Alessandra
    Toni, Aldo
    HIP INTERNATIONAL, 2020, 30 (04) : 438 - 445
  • [40] Quarter Century Outcomes of Alumina Ceramic-on-Ceramic Total Hip Arthroplasty
    Kim, Hong Seok
    Yoo, Jeong Joon
    JOURNAL OF ARTHROPLASTY, 2025, 40 (04): : 992 - 998