Heavy metals in untreated/treated urban effluent and sludge from a biological wastewater treatment plant

被引:109
|
作者
Oliveira, Aline da Silva
Bocio, Ana
Trevilato, Tania M. Beltramini
Takayanagui, Angela M. Magosso
Doming, Jose L.
Segura-Munoz, Susana I.
机构
[1] Univ Sao Paulo, Ribeirao Preto Coll Nursing, Dept Maternal Infant Nursing & Publ Hlth, Environm Hlth Lab, BR-14040902 Ribeirao Preto, SP, Brazil
[2] Univ Rovira & Virgili, Sch Med, Lab Toxicol & Environm Hlth, E-43201 Reus, Spain
[3] Univ Sao Paulo, Fac Med Ribeirao Preto, Met Sector,Pediat Dept, Gen Hosp, BR-14048900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
biological wastewater treatment plant; Brazil; metals; removal efficiency; ribeirao preto; wastewater;
D O I
10.1065/espr2006.10.355
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background. Aim and Scope. The presence of heavy metals in wastewater is one of the main causes of water and soil pollution. The aim of the present study was to investigate the removal of Cd, Cu, Pb, Hg, Mn, Cr and Zn in urban effluent by a biological wastewater treatment, as well as to quantify the levels of As, Be, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Sri, Tl, V and Zn in dewatering sludge from the Biological Wastewater Treatment Plant of Ribeirao Preto (RP-BWTP), Brazil. Materials and Methods. Concentrations of Cd, Cr, Cu, Mn and Pb in wastewater and those of Ni in sludge were determined by atomic absorption spectrophotometry with graphite furnace atomization. Mercury concentrations in wastewater were measured by hydride generation atomic spectrophotometry, and Zn levels were determined by atomic absorption spectrophotometry using acetylene flame. In sludge, the levels of As, Be, Cd, Cr, Cu, Fe, Fig, Mn, Pb, Sri, Tl, V and Zn were determined by inductively,coupled plasma-mass spectrometry. Results. The percentages of removal efficiency (RE) were the following: Hg 61.5%, Cd 60.0%, Zn 44.9%, Cu 44.2%, Pb 39.7%, Cr 16,5% and Mn 10.4%. In turn, the mean concentrations (mg/kg) of metals in dewatering sludge followed this increasing order: Tl (< 0.03), Hg (0.31), Be (0.43), As (1.14), Cd (1.34), V (59.2), Pb (132.1), Sn (166.1), Cr (195.0), Mn (208.1), Ni (239.4), Cu (391.7), Zn (864.4) and Fe (20537). Discussion. The relationship between metal levels in untreated wastewater, as well as the removal efficiency are in agreement with previous data from various investigators. It is important to note that metal removal efficiency is not only affected by metal ion species and concentration, but also by other conditions such as operating parameters, physical, chemical, and biological factors. Conclusions. Metal values recorded for treated wastewater and sludge were within the maximum permitted levels established by the Environmental Sanitation Company (CETESB), Sao Paulo, Brazil. Recommendations. There is an urgent need for the authorities who are responsible for legislation on sludge uses in agriculture of establishing safety levels for As, Be, Hg, Sn, Tl and V. Perspectives. According to the current metal levels, RP-BWTP sludge might be used for agriculture purposes. However, for an environmentally safe use of sewage sludge, further studies including systematic monitoring are recommended. Annual metal concentrations and predicted variations of those elements in the sludge should be monitored.
引用
收藏
页码:483 / 489
页数:7
相关论文
共 50 条
  • [21] Capacity to influence sources of heavy metals to wastewater treatment sludge
    Sörme, L
    Lindqvist, A
    Söderberg, H
    ENVIRONMENTAL MANAGEMENT, 2003, 31 (03) : 421 - 428
  • [22] Utilization of textile effluent wastewater treatment plant sludge as brick material
    B. Shathika Sulthana Begum
    R. Gandhimathi
    S. T. Ramesh
    P. V. Nidheesh
    Journal of Material Cycles and Waste Management, 2013, 15 : 564 - 570
  • [23] Impact of heavy metals on the formation and properties of solvable microbiological products released from activated sludge in biological wastewater treatment
    Zheng, Xing
    Liu, Tong
    Guo, Menghan
    Li, Dong
    Gou, Na
    Cao, Xin
    Qiu, Xiaopeng
    Li, Xiaoliang
    Zhang, Yaozhong
    Sheng, Guoping
    Pan, Baozhu
    Gu, April Z.
    Li, Zhanbin
    WATER RESEARCH, 2020, 179
  • [24] Incorporation of sludge from effluent treatment plant of an industrial laundry into heavy clay ceramics
    Girondi Delaqua, Geovana Carla
    Ferreira, Milena das Neves
    Amaral, Lucas Fonseca
    Sanchez Rodriguez, Ruben Jesus
    de Carvalho, Eduardo Atem
    Fontes Vieira, Carlos Mauricio
    JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [25] Utilization of textile effluent wastewater treatment plant sludge as brick material
    Begum, B. Shathika Sulthana
    Gandhimathi, R.
    Ramesh, S. T.
    Nidheesh, P. V.
    JOURNAL OF MATERIAL CYCLES AND WASTE MANAGEMENT, 2013, 15 (04) : 564 - 570
  • [26] Heavy Metal Pollution Loads and Relationships of Drying Beds Sludge in Urban Wastewater Treatment Plant
    Dere, Turgay
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (11) : 6343 - 6345
  • [27] Investigation of microplastics in advanced biological wastewater treatment plant effluent
    Arslan, Ayla
    Topkaya, Eylem
    Sezer, Mesut
    Aksan, Serdar
    Veli, Sevil
    MARINE POLLUTION BULLETIN, 2024, 203
  • [28] Analysis of organic compounds in an urban wastewater treatment plant effluent
    Departamento de Quimica, Instituto Universitario de Tecnologia Quimica CSIC-UPV, Universidad Politeácnica de Valencia, Camino de Vera S/N, 46022, Valencia, Spain
    Environ. Technol., 3 (295-306):
  • [29] Effect of ozonation on the biodegradability urban wastewater treatment plant effluent
    Phan, Lam Thanh
    Schaar, Heidemarie
    Saracevic, Ernis
    Krampe, Jorg
    Kreuzinger, Norbert
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 812
  • [30] Analysis of organic compounds in an urban wastewater treatment plant effluent
    Navalon, S.
    Alvaro, M.
    Garcia, H.
    ENVIRONMENTAL TECHNOLOGY, 2011, 32 (03) : 295 - 306