Immobilisation of glucose oxidase within metallic nanotubes arrays for application to enzyme biosensors

被引:128
|
作者
Delvaux, M [1 ]
Demoustier-Champagne, S [1 ]
机构
[1] Univ Catholique Louvain, Unite Chim & Phys Hauts Polymeres, B-1348 Louvain, Belgium
来源
BIOSENSORS & BIOELECTRONICS | 2003年 / 18卷 / 07期
关键词
template method; gold nanotubes; self-assembled monolayers; glucose oxidase; glucose sensor;
D O I
10.1016/S0956-5663(02)00209-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arrays of nanoscopic gold tubes were prepared by electroless deposition of the metal within the pores of polycarbonate particle track-etched membranes (PTM). Glucose oxidase (Gox) was immobilised onto preformed self-assembled monolayers (SAMs) (mercaptoethylamine or mercaptopropionic acid) on electroless gold via cross-linking with glutaraldehyde or covalent attachment by carbodiimide coupling. The effectiveness of the different steps in the Gox immobilisaition procedure was assessed by contact angle measurements, cyclic voltammetry and X-ray photoelectron spectroscopy. The enzyme loading was estimated by radioactivity measurements. The sensitivity to beta-glucose of these different biosensors has been evaluated. Glucose responses as large as 400 nA mM(-1) cm(-2) have been obtained. To our knowledge, this sensitivity value is amongst the highest values reported in the literature for comparable biosensor systems. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:943 / 951
页数:9
相关论文
共 50 条
  • [41] ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS
    FOULDS, NC
    LOWE, CR
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1259 - 1264
  • [42] A biosensor based on the self-entrapment of glucose oxidase within biomimetic silica nanoparticles induced by a fusion enzyme
    Choi, Okkyoung
    Kim, Byung-Chun
    An, Ji-Hye
    Min, Kyoungseon
    Kim, Yong Hwan
    Um, Youngsoon
    Oh, Min-Kyu
    Sang, Byoung-In
    ENZYME AND MICROBIAL TECHNOLOGY, 2011, 49 (05) : 441 - 445
  • [43] Sonochemically fabricated microelectrode arrays for biosensors - Part III. AC impedimetric study of aerobic and anaerobic response of alcohol oxidase within polyaniline
    Myler, S
    Collyer, SD
    Davis, F
    Gornall, DD
    Higson, SPJ
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (04): : 666 - 671
  • [44] Direct electron transfer of glucose oxidase at glassy carbon electrode modified with functionalized carbon nanotubes within a dihexadecylphosphate film
    Janegitz, Bruno C.
    Pauliukaite, Rasa
    Ghica, Mariana E.
    Brett, Christopher M. A.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 158 (01) : 411 - 417
  • [45] Gold nanoparticles: Poly(diallyldimethylammonium chloride)-carbon nanotubes composites as platforms for the preparation of electrochemical enzyme biosensors: Application to the determination of cholesterol
    Eguilaz, M.
    Villalonga, R.
    Aguei, L.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (01) : 171 - 178
  • [46] Fast and clean dielectric barrier discharge plasma functionalization of carbon nanotubes decorated by electrodeposited nickel oxide: Application to glucose biosensors
    Khodadadi, A. A.
    Mortazavi, Y.
    Vesali-Naseh, M.
    SCIENTIA IRANICA, 2019, 26 (06) : 3896 - 3904
  • [47] IMMOBILIZATION OF D-GLUCOSE OXIDASE ONTO A HYDROGEN-PEROXIDE PERMSELECTIVE MEMBRANE AND APPLICATION FOR AN ENZYME ELECTRODE
    TSUCHIDA, T
    YODA, K
    ENZYME AND MICROBIAL TECHNOLOGY, 1981, 3 (04) : 326 - 330
  • [48] Immobilization of glucose oxidase enzyme on NiAl-LDHs for application in microfluidic fuel cell and serotonin detection.
    Galindo-de-la-Rosa, J.
    Araiza-Ramirez, M. G.
    Hernandez-Torres, A.
    Ledesma-Garcia, J.
    Arriaga, L. G.
    18TH INTERNATIONAL CONFERENCE ON MICRO AND NANOTECHNOLOGY FOR POWER GENERATION AND ENERGY CONVERSION APPLICATIONS, 2019, 1407
  • [49] POLYAZULENES .5. COVALENT BINDING OF GLUCOSE-OXIDASE TO FUNCTIONALIZED POLYAZULENES - THE 1ST APPLICATION OF POLYAZULENES IN AMPEROMETRIC BIOSENSORS
    SCHUHMANN, W
    HUBER, J
    MIRLACH, A
    DAUB, J
    ADVANCED MATERIALS, 1993, 5 (02) : 124 - 126
  • [50] DEVELOPMENT OF NOVEL BIOSENSOR ENZYME ELECTRODES - GLUCOSE-OXIDASE MULTILAYER ARRAYS IMMOBILIZED ONTO SELF-ASSEMBLED MONOLAYERS ELECTRODES
    WILLNER, I
    RIKLIN, A
    SHOHAM, B
    RIVENZON, D
    KATZ, E
    ADVANCED MATERIALS, 1993, 5 (12) : 912 - 915