LEDA beam diagnostics instrumentation: Beam position monitors

被引:0
|
作者
Barr, D [1 ]
Day, L [1 ]
Gilpatrick, JD [1 ]
Kasemir, KU [1 ]
Martinez, D [1 ]
Power, JF [1 ]
Shurter, R [1 ]
Stettler, M [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
来源
BEAM INSTRUMENTATION WORKSHOP 2000 | 2000年 / 546卷
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7 MeV and current of 100 mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS320C40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 50 条
  • [31] Beam position monitors for the Fermilab recycler ring
    Barsotti, E
    Lackey, S
    McClure, C
    Meadowcroft, R
    BEAM INSTRUMENTATION WORKSHOP, 1998, 451 : 332 - 339
  • [32] CHARACTERISTICS OF DIRECTIONAL COUPLER BEAM POSITION MONITORS
    SHAFER, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 1933 - 1937
  • [33] Performance of the upgraded NSLS beam position monitors
    Nawrocky, R.J.
    Keane, J.
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 2 : 2069 - 2071
  • [34] CAMBRIDGE ELECTRON ACCELERATOR BEAM POSITION MONITORS
    LAW, LA
    HOLCOMB, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1965, NS12 (03) : 856 - &
  • [35] BEAM POSITION MONITORS FOR STORAGE-RINGS
    BILLING, MG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 144 - 154
  • [36] BEAM CURRENT AND POSITION MONITORS AT NBS LINAC
    MENKE, JL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1971, NS18 (03) : 909 - &
  • [37] Instrumentation and diagnostics for the ITER Neutral Beam System
    Svensson, Lennart
    Hemsworth, Ronald S.
    Schunke, Beatrix
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 934 - 937
  • [38] Comparison of beam-position-transfer functions using circular beam-position monitors
    Gilpatrick, JD
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2090 - 2092
  • [39] Waveguide monitors - a new type of beam position monitors for the TTF FEL
    Hahn, U
    Kamps, T
    Lorenz, R
    Riesch, W
    Schreiber, HJ
    Tonisch, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (03): : 240 - 252
  • [40] Beam position monitoring - A discussion session at the 2000 Beam Instrumentation Workshop
    Shea, TJ
    BEAM INSTRUMENTATION WORKSHOP 2000, 2000, 546 : 650 - 670