Computation of AC critical flashover voltage of insulators covered with ice

被引:0
|
作者
Zhang, J [1 ]
Farzaneh, M [1 ]
机构
[1] Univ Quebec, Ind Chair Atmospher Icing Power Line Equipments, Chicoutimi, PQ G7H 2B1, Canada
关键词
ice; insulator; modeling; arc; flashover;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using a high-speed frame camera, the behavior of the partial are on triangular ice samples was studied under AC voltage. The relationship between the radius of partial. arc root and the leakage current was determined. Based on the model developed in our previous studies and the results obtained in the present work, the model was improved and used to calculate the flashover voltage of ice-covered insulators. This model takes into account the variation of arc root radius with leakage current. It was shown that there was a good concordance between the results calculated from the model and the laboratory results.
引用
收藏
页码:524 / 528
页数:5
相关论文
共 50 条
  • [41] Calculation of AC flashover voltage of polluted double-shed insulators
    Chen, Li-Qin
    Zhou, Jun
    Shi, Wei-Dong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (04): : 952 - 956
  • [42] Modeling of altitude effects on AC flashover of polluted high voltage insulators
    Rizk, FAM
    Rezazada, AQ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (02) : 810 - 822
  • [43] Effect of icing on the AC flashover voltage of 220 kV composite insulators
    Wang, Huan
    Hu, Qin
    Lin, Huiyao
    Xu, Hang
    Shu, Lichun
    Yin, Pancheng
    Jiang, Xingliang
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 238
  • [44] Effects of Artificial Polluting Methods on AC Flashover Voltage of Composite Insulators
    Dong, Bingbing
    Jiang, Xingliang
    Hu, Jianlin
    Shu, Lichun
    Sun, Caixin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (02) : 714 - 722
  • [45] Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 WUHV AC transmission lines
    Hu, Jianlin
    Sun, Caixin
    Jiang, Xingliang
    Zhang, Zhijin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1347 - 1356
  • [46] An empirical expression for the determination of the effects of rain on the AC flashover voltage of high voltage insulators
    Lpizra, MA
    Egbert, RI
    ELECTRIC POWER SYSTEMS RESEARCH, 1997, 43 (01) : 29 - 36
  • [47] The estimation of the critical flashover voltage of insulators using the computational intelligence
    Dehyadegari L.
    Khajehasani S.
    Recent Advances in Computer Science and Communications, 2020, 13 (04) : 550 - 556
  • [48] Lightning Critical Flashover Voltage of High Voltage Insulators: Laboratory Measurements and Calculations
    Filipovic-Grcic, Dalibor
    Filipovic-Grcic, Bozidar
    Uglesic, Ivo
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (02): : 4321 - 4328
  • [49] AC surface flashover voltage of ice depending on soluble ions
    Sugawara, N
    Ito, S
    Nakauchi, H
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 433 - 436
  • [50] Dynamic model to predict AC critical flashover voltage of nonuniformly polluted insulators under thermal ionization conditions
    Shahabi, Saeed
    Gholami, Ahmad
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (03) : 2322 - 2335